Mounting and commissioning
22
Europress
1
To leak detector
2
Inlet opening
Fig. 9: Connect the drying filter in series
2.
Connect the drying filters and the leak detectors by means of a
hose; hose connections must be secured by means of hose
clamps which fit over the entire circumference.
3.
Fill the drying filter with orange drying beads.
The colour of the drying beads changes from orange to colourless as
they absorb moisture. When the drying beads are colourless, they
must be replaced since they are no longer able to absorb moisture.
Drying beads which are colourless after commissioning must be re-
placed. The service life of the drying beads during normal operation
is at least 1 year. The drying beads must be replaced after one year
or when they have become colourless.
6.7
Valve settings
Valve setting
Measurement valve at
red measurement line
connection
Test valve at white suc-
tion line connection
Normal operation
Normal operation
Test with pressure gauge
Venting
Test safety valve
Not permissible
Not permissible
Not permissible
Summary of Contents for 43790
Page 34: ...Appendix 34 Europress 16 2 Approval documents ...
Page 35: ...Appendix Europress 35 ...
Page 36: ...Appendix 36 Europress ...
Page 37: ...Appendix Europress 37 ...
Page 38: ...Appendix 38 Europress ...
Page 39: ...Appendix Europress 39 ...
Page 40: ...Appendix 40 Europress ...