CHAPTER 3: Troubleshooting
3.3.3 TROUBLESHOOTING- HEART RATE ISSUES
SOLUTION:
1.
T
elemetric HR:
a. Re-center the HR strap on user's chest, strap mast have some moisture for good connection.
b. Replace the battery in the wireless HR Strap.
2.
HR grips
c. Wet user's hand, and then reestablish contact with the HR grip.
d. With a multi-meter. set for DC voltage, place one terminal on each of the HR grip plates. The HR
grip should give a voltage reading of between 0.5 and 2.0VDC. If the voltage is not between 0.5
and 2.0VDC remove the screws holding the HR grip together and check the connection of the
HR grip wiring.
e. If the console still does not display proper HR, replace the HR grips.
f. Check a - e. If the HR still does not work, replace the console.