![Afar NX-2E1 Operator'S Manual Download Page 14](http://html.mh-extra.com/html/afar/nx-2e1/nx-2e1_operators-manual_2864045014.webp)
NetCrossing Gateway NX-2E1/T1 Operator’s Manual
1-4
Table 1.2 – Front Panel LEDs
LED
Function
Gateway/
Power
Indicates that there is DC power applied to the unit.
Radio/
Power
Indicates that there is current being drawn by the radio connected to the WAN/Radio
connector.
Gateway/
Link
“OFF”: There are no serial links between this and other gateways specified or enabled.
“RED”: One or more of the serial links that have been enabled is not established.
“AMBER”: All enabled links are established, but an error has been detected in any of
the links.
“GREEN”: All enabled links are established; no errors have been detected.
“Steady Blink ON/OFF”: A serial link to another gateway has just been established
and the gateways are measuring and adapting to the jitter in the network.
“Momentary Blink”: Every time that an error is detected the LED will go momentarily
OFF
Radio/
Link
If the wide area network connecting the two gateways consists of a radio link using the
AFAR radios, this LED indicates the state of the associated radio as follows:
”OFF”: The gateway has no communications with the local radio
“2 second off/ blink ON”: the associated radio is in auto SYNC mode and waiting for
a transmission from a peer radio or for an sync message (heartbeat) from the gateway.
“Half second blink ON/OFF”: The associated radio has a heartbeat and is transmitting.
However it has not yet received a reply from a peer radio.
“Steady ON”: The radio has found a peer and an RF link is established between the
two radios.
Ethernet/
LAN
Indicates that there is an Ethernet connection on the LAN port. The LED blinks for
each packet received.
Ethernet/
WAN
Indicates that there is an Ethernet connection on the WAN port.
E1/T1
Local
OFF: This TDM serial port is disabled
RED: The serial port is enabled but no signal is detected at its Rx Line (red alarm)
AMBER: The gateway is detecting an alarm in this TDM Rx line
GREEN: The TDM Rx line is active with no alarms.
E1/T1
Remote
OFF: There is no connection with a remote device for this serial port
RED: The remote gateway is reporting a red alarm (no signal) in its input line.
AMBER: The remote gateway is reporting an alarm in its TDM Rx line
GREEN: The remote gateway is reporting no alarms in its TDM Rx line