SA-1-OI-vers. 2.2 gb.23.07.14
4.1.5 Trouble-shooting
Faulte during the reference run.
Fault
Possible cause
Fault clearance
Slide oscillates (very
strong vibrations at the
drive)
Wrong setting of control
parameters
Reset parameters at the
control system
Slide moves to the
retracted limit position
and stops
Wrong connection of limit
sensor
Check pin assignment and
correct, if necessary
Limit sensor connection
interrupted
Check sensor cable
Limit sensor
defective
Replace limit sensor
according to the repair
instructions.
Slide moves to the
extended limit position
and stops
Wrong direction of
reference run
Check direction of
reference run and change,
if necessary
Slide does not move
Wrong connection of drive
Check pin assignment and
correct, if necessary
Carry out functional test
according to chapter "First
start-
up”
Motor connection
interrupted
Check motor cable
Drive defective
Have the drive replaced by
Afag automation AG
CAUTION
If the movable part of the module is oscillating heavily after the
control system has been switched on (strong vibrations at the
drive), switch off the module immediately, since otherwise the
unit and the subsystems attached may get damaged.
37
Summary of Contents for SA-1 Series
Page 10: ...SA 1 OI vers 2 2 gb 23 07 14 2 1 4 Slide unit load factors 10 ...
Page 18: ...SA 1 OI vers 2 2 gb 23 07 14 2 2 2 SE 24 18 ...
Page 19: ...SA 1 OI vers 2 2 gb 23 07 14 2 2 3 SE 48 19 ...
Page 20: ...SA 1 OI vers 2 2 gb 23 07 14 2 2 4 SE Power 20 ...
Page 21: ...SA 1 OI vers 2 2 gb 23 07 14 2 2 5 Servo controller 21 ...
Page 30: ...SA 1 OI vers 2 2 gb 23 07 14 3 1 6 Dimension for SA 1 30 ...
Page 31: ...SA 1 OI vers 2 2 gb 23 07 14 3 1 7 Technical data 31 ...