SA-1-OI-vers. 2.2 gb.23.07.14
4.0.0 Maintenance instructions
4.1.0 Maintenance and service the telescope spindle axis
CAUTION
With switched control of the SA-1 can run extra movement and
cause injury or property damage. Make sure that the control
system is switched off and secured against being switched on
again when working on the axis.
Maintenance
interval
Services measures
As required
Clean the module with a dry, lint-free cloth.
The module must not be washed down; do not use any
aggressive cleaners.
1 Montly
Check the safety labels for damage, readability and
cleanliness.
Every 4 million load
alternations
Every 10 million
load alternations
Lubrication of the spindle drive
Recommended grease: Klüber Microlube GBU-Y-131
Optional grease:
type KP-1, N (DIN 51502)
type NLGI-class 1 (DIN 51818)
Lubrication of the linear guide
Recommended grease: Klüber STABRAGS NBU 8 EP
Optional: Type KP2K NLGI-classe 2 (DIN51818)
CAUTION
Lubricants with additives such as MoS
2
, graphite or PTFE may not
be used to service the linear guide.
33
Summary of Contents for SA-1 Series
Page 10: ...SA 1 OI vers 2 2 gb 23 07 14 2 1 4 Slide unit load factors 10 ...
Page 18: ...SA 1 OI vers 2 2 gb 23 07 14 2 2 2 SE 24 18 ...
Page 19: ...SA 1 OI vers 2 2 gb 23 07 14 2 2 3 SE 48 19 ...
Page 20: ...SA 1 OI vers 2 2 gb 23 07 14 2 2 4 SE Power 20 ...
Page 21: ...SA 1 OI vers 2 2 gb 23 07 14 2 2 5 Servo controller 21 ...
Page 30: ...SA 1 OI vers 2 2 gb 23 07 14 3 1 6 Dimension for SA 1 30 ...
Page 31: ...SA 1 OI vers 2 2 gb 23 07 14 3 1 7 Technical data 31 ...