Installation, assembly and setting
Assembly instructions
EN
PEL20 I PEL20-SL I PDL30 I PDL40 I PDL40-HP
06.09.2021
Version 4.0 53–68
6.6.3 Switching distance - reference sensor for electric axes
The reference sensor of the rotational axes is mounted with a feeler gauge at
a distance of 0.1 mm parallel to the switching lug. The positions can be found
in the respective drawings (note the axle types).
6.6.4 Rotatability of C motor connector (PDL30/40)
If C-motor connector are provided for the PDL30/40 modules, the C-connector
can be rotated in both directions (see Fig. 14). In this case, the maximum
rotatability of the C-connector must be observed.
C-Connector
Fig. 14
Setting the C-motor connector (PDL30/40 modules)
Our service technicians will be happy to answer any further questions you
may have about setting the C-motor plugs.
NOTICE
Risk of damage to the motor!
Do not overtighten the motor connector beyond the intended position, as this
will damage the motor.
If it is necessary to adjust the connector, always observe the maximum
permissible rotatability (see Fig. 14).