R05.1
12/02/2020
Page 17
Linear feeder does not run after switching it on
Cause of fault:
Fault repair
Plug not connected
Connect plug
Connecting cable between bowl feeder
and controller not plugged in
Connect plug
Regulator on controller set to „0“
Turn regulator to position
Defective fuse in control unit
Replace fuse
Bowl feeder lacks performance after operating for a certain length of time
Cause of fault:
Fault repair
The spring package fixing screws have
become loose
Remove the casing and retighten all spring
package screws
The air gap between the magnetic coil
and the anchor bolt is no longer correct
Remove the casing and readjust the air
gap
(See chapter 5.4)
Spring broken
Remove the casing and replace the broken
spring
(See chapter 5.2)
Regulator on control unit has moved
Readjust regulator
Bowl feeder develops loud noises
Cause of fault:
Fault repair
The magnetic coil or anchor bolt have
become loose
Tighten the screws
(See chapter 5.3)
Transport-speed incorrect
Cause of fault:
Fault repair
Potentiometer defective
Replace potentiometer (See „Controller
operating instructions“)