AES uScope Getting Started Download Page 4

AES uScope Manual

 

 

www.AESwave.com

        Copyright 2011 by Automotive Electronics Services, Inc.

 

Page 4 

 

Main Buttons

 

         

 

[On/Off] 

Turn uScope on or off 

Slide switch located on bottom right side of uScope

 

 
  
[A] 

 

Two actions  

 

1.  Quick press 

A quick Press 

of “A” will switch between “stop” or “run” of 

the waveform.  
 

2.  Long Press 

Hold for 1 full second (or until the screen changes) to 
switch between the Main Menu or the Grid Value 
displays.  
 
For further instructions on saving an image or setup, refer 
to the manul. 

 

[B] 

 

Save Button (Located on the right) 

 
Press and hold 

“B”, 

while in grid value mode 

and in measurement menu

 

“ME”, 

to save an image of the screen.

   

 

 

  

 

[Arrows] 

Navigation (located on right side of the front 

face)  

 
When the Main Menu is visible:  
 

o

 

Up and down arrows: move between main menu and 
menu items 

o

 

Left and right arrows: make adjustments/selections for 
the currently highlighted menu item. 

  
 

[OK]   

Select menu Items 

(“OK” = menu) 

 

When the Main Menu is visible, “M” will open or close the currently selected menu item.  
For example, when “Tr” is highlighted, press “OK” to open the “Tr” menu item. Press “OK” 
to close it. 
 

Long Press 

“OK”

 

When a menu item calls for a selection, a long press of 

“OK” will close the window and 

select the action. 

 

 

 

Summary of Contents for uScope

Page 1: ...for the student that is ready to start scope n The uScope is powered by an easy to use interface enhanced with automotive presets and reference waveforms Put the power of the uScope in your hand and shirt pocket Secondary ignition injectors mass air flow crank cam TPS 02 CTS you name it it ll scope it The uScope is also perfect for your low amp probe secondary ignition pickup and pressure transduc...

Page 2: ...ll short o Always connect your test lead to the uScope before connecting to a circuit o Always disconnect from the circuit before disconnecting from the uScope Circuit Testing while Charging uScope It is not recommended to connect the uScope input channel to a circuit while the uScope is charging Doing so may result in a ground loop that can destroy equipment and possibly endanger the user Intende...

Page 3: ...gnal generator DO NOT USE THIS PORT WHEN TESTING AN AUTOMOTIVE CIRCUIT USB to PC Connection and Charging Port The USB connector is a standard micro USB and is located in the middle left side of unit This port is used for PC and uScope communication and for charging the uScope Memory Card microSD Card The uScope incorporates a microSD memory card The card port is located in the center of the bottom...

Page 4: ... Button Located on the right Press and hold B while in grid value mode and in measurement menu ME to save an image of the screen Arrows Navigation located on right side of the front face When the Main Menu is visible o Up and down arrows move between main menu and menu items o Left and right arrows make adjustments selections for the currently highlighted menu item OK Select menu Items OK menu Whe...

Page 5: ...hlight Auto Setup and press hold OK to activate it Waveform Capture not using a PreSet 1 Turn on the uScope by sliding the switch located on the top right of unit to the right 2 Use the UP DOWN arrow keys and highlight the Tr Trigger menu item 3 Press OK and the menu will open 4 Use the UP DOWN arrow keys to highlight the Tr Mode Trigger Display Mode Menu item 5 Use the LEFT RIGHT arrow keys to se...

Page 6: ...the Tr Level Trigger voltage level Menu item e Use the LEFT RIGHT arrow keys to set the trigger level The LEFT arrow key moves the trigger level down and the RIGHT key moves the trigger level up Note the Yellow dotted horizontall line in the display indicating the selected level f Note When Tr level menu item is selected The numerical value of the Trigger will be displayed on the top right of the ...

Page 7: ...vices Inc Page 7 Switching between MENU and Grid Values To switch between GRID VALUES and the MAIN MENU press and hold the A button for approximaely 5 seconds Please note Tapping the A button for less than 5 seconds will hold the signal Display with Grid Values Display with Menu ...

Page 8: ... screen will indicate if invert is on or off o The following will be displayed at the button right of the screen if invert is on INV Press OK when complete to close menu Ref Vert Pos Reference Vertical Position Highlight Ref Vert Pos Use the LEFT RIGHT to pick the desired position of the reference waveform Press OK to exit the menu T Time and Horizontal Setting Menu Highlight the T and press OK to...

Page 9: ...zontal cursors Press OK to exit menu Tr HPos Trigger Horizontal Position Highlight HPos Use LEFT RIGHT to select the trigger horizontal position Press OK to exit menu PS Automotive Presets Menu memory card must be inserted Select the PS menu item and press OK to activate the menu Use UP DOWN to select preset type Use LEFT RIGHT to scroll through different preset setups Press and hold OK to load se...

Page 10: ...ff measurement values Use UP DOWN and select Enable On OFF Use LEFT RIGHT to toggle between ON OFF Press OK to exit menu OP Options Highlight the OP and press OK to activate the menu Probe Cal Probe Calibration Highlight Probe Cal At the top right of the screen the uScope will specify what attenuation setting you are currently on Note 10x does not change anything within the scope other than the vo...

Page 11: ...tup See below Press OK to exit menu Set Custom Startup Set current settings as default Highlight Set Customer Startup using UP DOWN Press and hold OK Message will appear on the upper right confirming the save Save ok Press OK to exit menu Reset Factory Default To reset your uScope to factory default settings Use UP DOWN to select Reset Factory Default Press and hold OK You will see a message flash...

Page 12: ... Capture a Waveform onto a PC Turn the uScope On Plug the uScope into an available USB port on a computer Note The waveforms and presets are saved onto the uScope memory card Never remove the memory card doing so will interrupt some of the uScopes functions The uScope memory card will act as removable mass storage once plugged into your pc The folder can be accessed through my computer under Devic...

Reviews: