9. POWER SUPPLY
9.5. Position of the power
- No liquid may be allowed to enter the unit.
- The ambient temperature should lie between 10°and
27℃, do not place on or directly adjacent to a heat source.
- Do not expose to direct sunlight..
- Do not place any objects on top.
- Do not use close to inflammable materials or in a places
where inflammable vapors or smoke can occur.
9.6. Connection via the vehicle’s battery
It is recommended running the vehicle’s motor for
approx.15 minutes every hour to prevent the battery from
discharging. The power inverter can be operated when the
motor is running or when the motor is at a standstill.
It is possible that the power inverter may not work due to
the voltage drop during the starting process.
9.7. Alarm (low battery voltage)
The power inverter switches off automatically when the
voltage drops below 10 Volt.
9.8. Malfunctions (Protective features of the power
inverter)
Low battery voltage may damage the battery but not the
power inverter as it switches off. Once the normal
operating voltage is reinstated, the unit can be operated
again.
Overload protection - If the incoming voltage exceeds
15Volt DC, or if the permanent output is exceeded, the unit
switches off automatically.
12