Installation and Configuration
Ensemble LAB Hardware Manual
N O T E :
Outputs must be connected as all sourcing or all sinking.
OPTOCOM
5-24 VDC
2
1
1
2
EACH OUTPUT 50 mA MAXIMUM
OUTPUT SWITCHES
J106
J106-15
J106-7
J106-8
J106-9
J106-16
DIODE REQUIRED ON EACH OUTPUT THAT DRIVES AN INDUCTIVE DEVICE (COIL), SUCH AS A RELAY.
+
-
+
LOAD
-
+
LOAD
-
+
LOAD
-
+
LOAD
-
OPTOOUT0
OPTOOUT1
OPTOOUT2
OPTOOUT3
Figure 2-24:
Outputs Connected in Current Sourcing Mode (J106)
OPTOCOM
5-24 VDC
2
1
1
2
EACH OUTPUT 50 mA MAXIMUM
OUTPUT SWITCHES
J106
J106-15
J106-7
J106-8
J106-9
J106-16
DIODE REQUIRED ON EACH OUTPUT THAT DRIVES AN INDUCTIVE DEVICE (COIL), SUCH AS A RELAY.
+
-
+
LOAD
-
+
LOAD
-
+
LOAD
-
+
LOAD
-
OPTOOUT0
OPTOOUT1
OPTOOUT2
OPTOOUT3
Figure 2-25:
Outputs Connected in Current Sinking Mode (J106)
50
Chapter 2
www.aerotech.com