34
ENGLISH
ESPAÑOL
DEUTSCH
ITALIANO
FRANÇAIS
2
.
0
P26
Heating proportional
band (°C)
0
.
9
..
8
.
0
2
.
0
P27
Cooling proportional
band (°C)
0
.
9
..
8
.
0
0
P28
Heating integrative
time (minutes)
0
..
30
0
P29
Cooling integrative
time (minutes)
0
..
30
33
P30
Fan MIN
speed (FI1)
1
..
100
66
P31
Fan MED
speed (FI2)
1
..
100
100
P32
Fan MAX
speed (FI3)
1
..
100
0
P33
Fan-coil signal
lower limit
0
.
0
..
10
.
0
10
.
0
P34
Fan-coil signal
upper limit
0
.
0
..
10
.
0
0
P35
Dirty filter warning
time (x 100 hours)
0
..
50
END
0
.
0
P12
Room temperature
correction (offset) (°C)
-5
.
0
..
5
.
0
10
.
0
P13
Heating set-point knob
lower limit (°C)
5
.
0
..
35
.
0
30
.
0
P14
Heating set-point knob
upper limit (°C)
5
.
0
..
35
.
0
10
.
0
P15
Cooling set-point knob
lower limit (°C)
5
.
0
..
35
.
0
30
.
0
P16
Cooling set-point knob
upper limit (°C)
5
.
0
..
35
.
0
0
.
0
P17
Anti-freeze threshold
temperature (°C)
0
.
0
..
15
.
0
0
.
0
P18
Economy
reduction (°C)
0
.
0
..
10
.
0
0
.
2
P19
Ambient temperature
hysteresis (°C)
0
.
2
..
1
.
0
3
.
0
P20
Neutral zone
width (°C)
1
.
0
..
11
.
0
0
P21
Fan delay at
turn-on (seconds)
0
..
600
0
P22
Fan delay at
turn-off (seconds)
0
..
600
17
P23
Changeover
lower threshold (°C)
0
..
24
30
P24
Changeover
upper threshold (°C)
26
..
48
40
P25
Cut-off thermostat
threshold temperature (°C)
0
..
99
Summary of Contents for WMT20