background image

AERMEC S.p.A. 

37040 Bevilacqua (VR) Italy–Via Roma, 996 

Tel. (+39) 0442 633111 Telefax (+39) 0442 93577 

www.aermec.com - [email protected] 

 

 
 
 

 

DICHIARAZIONE DI CONFORMITÁ UE 

La presente dichiarazione di conformità è rilasciata sotto la responsabilità esclusiva del fabbricante. 

EU DECLARATION OF CONFORMITY 

This declaration of conformity is issued under the sole responsibility of the manufacturer. 

DÉCLARATION DE CONFORMITÉ UE 

La présente déclaration de conformité est établie sous la seule responsabilité du fabricant. 

EU-KONFORMITÄTSERKLÄRUNG 

Die alleinige Verantwortung für die Ausstellung dieser Konformitätserklärung trägt der Hersteller. 

DECLARACIÓN DE CONFORMIDAD UE 

La presente declaración de conformidad se expide bajo la exclusiva responsabilidad del fabricante: 

Tipo / Type / Type / Typ / Tipo 

                 VENTILCONVETTORE  / FAN COIL / VENTILO-CONVECTEURS / GEBLÄSEKONVEKTOR / FAN COIL

 

Modello / Model / Modèle / Model / Modelo 

 

 

 Sigla / Code / Sigle / Abkürzung /Sigla

 

 

   Numero di Serie / Serial Number / Nùmero de Sèrie / Seriennummer / Nùmero de Serie 

 

Data / Date / Date / Datum / Fecha

 

 

 

 

 

 

 

L’oggetto della dichiarazione di cui sopra è conforme alla pertinente normativa di armonizzazione dell’Unione: 
The object of the declaration described above is in conformity with the relevant Union harmonisation legislation: 
L’objet de la déclaration décrit ci-dessus est conforme à la législation d’harmonisation de l’Union applicable:

 

Der oben beschriebene Gegenstand der Erklärung erfüllt die einschlägigen Harmonisierungsrechtsvorschriften der Union: 
El objeto de la declaración descrita anteriormente es conforme con la legislación de armonización pertinente de la Unión:

 

CEI EN 60335-2-40: 2005  +  CEI EN 60335-2-40/A1: 2007

 

CEI EN 55014-1: 2008 

CEI EN 55014-2: 1998 

CEI EN 61000-6-1: 2007

 

CEI EN 61000-6-3: 2007

 

 

Soddisfacendo così i requisiti essenziali delle seguenti direttive:  
Thus meeting the essential requisites of the following directives: 
Satisfaisant ainsi aux conditions essentielles des directives suivantes:

 

Womit die grundlegenden Anforderungen folgender Richtlinien erfüllt werden:

 

Al que esta declaración se refiere, está en conformidad a las siguientes normas armonizadas:

 

 

LVD 2014/35/UE 

EMC 2014/30/UE 

 

Direttiva Bassa Tensione / Low Voltage Directive / Directive Basse Tension/ Niederspannungsrichtlinie / Directiva de Baja de Tensión 

Direttiva Compatibilità Elettromagnetica /  Electromagnetic Compatibility Directive  /  Directive  compatibilité 
électromagnétique / Richtlinie zur elektromagnetischen Verträglichkeit / Directiva Compatibilidad Electromagnétic 

 

 

MODELLO CON ACCESSORI : 

E’ fatto divieto di mettere in servizio il prodotto dotato di accessori non di fornitura Aermec. 

MODEL WITH ACCESSORIES : 

It is not allowed to use the unit equipped with accessories not supplied by Aermec. 

MODÈLE PLUS ACCESSOIRES : 

Il est interdit de faire fonctionner l’appareil avec des accessoires qui ne sont pas fournis de Aermec. 

 ZUBEHÖR : 

Falls das Gerät mit Zubehörteilen ausgerüstet wird, die nicht von Aermec geliefert werden, ist dessen Inbetriebnahme solange untersagt. 

MODELO CON ACCESORIOS: 

Está prohibido poner en marcha el producto con accesorios no suministrados por Aermec. 

 

Firmato a nome e per conto di: 
Signed for and on behalf of: 
Signé par et au nom de: 
Unterzeichnet für und im Namen von: 
Firmado en nombre de: 

 

AERMEC S.p.A. 

 

I-37040 Bevilacqua (VR) Italia - Via Roma, 996 

 

 
 
 
 

Direttore Commerciale – Sales Director 

Luigi Zucchi 

 

Summary of Contents for FCW Series

Page 1: ...42VLN IFCW3LJ 1508 5138800_00 IT GB FR DE ES pag 5 pag 26 pag 47 pag 68 pag 89 VENTILCONVETTORE PER INSTALLAZIONE A PARETE t DKhEd E K hE d s Ed K KEs d hZ WKhZ E d d KE DhZ GEBL SEKONVEKTOR F R WAND...

Page 2: ...egislaci n de armonizaci n pertinente de la Uni n CEIEN60335 2 40 2005 CEIEN60335 2 40 A1 2007 CEIEN55014 1 2008 CEIEN55014 2 1998 CEIEN61000 6 1 2007 CEIEN61000 6 3 2007 Soddisfacendo cos i requisiti...

Page 3: ...3 General information 34 Important information Operational limits 35 Direction of the air flow 36 Control keys and signals FCW with microprocessor controller 37 TLW2 Infra red remote control 38 PFW2 W...

Page 4: ...aged in transit If any anomalies are found immediately notify the haulier of the damage immediately notify the vendor of the damage t d The electric and electronic equipment must be handled separately...

Page 5: ...perations that involve dismantling of the fan coil unit or its components to ensure the maximum fan coil unit efficiency is restored Operations Internal cleaning annually or after long periods of inac...

Page 6: ...tions Several versions of FCW fan coil units are available in order to satisfy all types of installations with internal 2 way valve with internal 3 way valve without valve Each version is available Wi...

Page 7: ...all the operating parameters of the unit These parameters are shown on a liquid crystal dis play making programming operations easier The remote control is supplied with a bracket allowing it to be hu...

Page 8: ...ts again automatically with the same settings that it had at the time of stop ping with the exception of the Timer and Sleep settings DWKZd Ed E KZD d KE t ZE E d K d E t Regulations D hE d KE WKt Z d...

Page 9: ...0 V and ensure it remains within the limit of 10 with respect to the nominal value OPERATING ENVIRONMENT d of urban non marine atmosphere with non corrosive and non dusty h which the unit must operate...

Page 10: ...nually h d E d s Zd turn the vertical blades as indicated in the diagram both in heating or cooling mode it is advisable for the air flow not to hit people directly DKdKZ KZ KEd E cause a malfunction...

Page 11: ...5 C automatic ventila tion swinging blades Second press Heating with set point 22 C automatic venti lation swinging blades Third press Fan coil unit turned off t hy Set the operation mode Cooling Firs...

Page 12: ...f the horizontal blades Khs Z Press this button to regulate the vertical air flow with 4 fixed positions plus swinging blades E Press this button to transmit the parameters shown on the display to the...

Page 13: ...attery cover DWKZd Ed The two control types wired control panel and remote control can be used at the same time on the same fan coil unit The batteries have an average life of 10 months when used norm...

Page 14: ...off but powered it sets and displays the hours off before the programmed turn on t E KZ KEd Press this button to control the vertical air flow The first press starts the blades swinging The second pre...

Page 15: ...rameters shown on the LCD to the main control unit t d WW E t E d hdKD d WZK Z DD d With AUTO programme the control system decides the type of operation COOL or HEAT on the basis of the water and room...

Page 16: ...shown on the LCD to the main control unit 6 PFW2 TLW2 WZ d KE K OR z The fan coil comes on and the display is switched on WZ d DK z Press the MODE key repeatedly until the word FUN appears on the dis...

Page 17: ...If you wish to stop the blade in a particular position press the SWINGkey again WZ d E z d t To transmit the new parameters shown on the LCD to the main control unit d PFW2 TLW2 Tset 3 C Tset 2 C Tse...

Page 18: ...e control dK E d d D Z dd E TLW2 Press the key to cancel the timer setting PFW2 Press the TIMER key for 3 seconds to cancel the timer setting Press the or key to manually turn ON the unit while the ti...

Page 19: ...wn in the manual determined by the room temperature and humidity conditions These limits refer to unit operation with fan at minimum speed In order to avoid air stratification and therefore achieve be...

Page 20: ...on densate is connected to the sewage sys tem The service hole for the piping can be located on the right or left of the unit The support wall must be sturdy and not subject to vibrations Do not insta...

Page 21: ...Screws Screw covers nents of the unit paying attention that the debris from the materials used for the installation do not block the fan or obstruct the filters or the grilles After installation perfo...

Page 22: ...cable FCW_2V FCW_3V FCW_VL FCW_2VN FCW_3VN FCW_VLN IG 2A 1 5mm2 WARNING operations on the unit d ent circuit W s To protect the unit against short circuits s The electrical power cable must be of the...

Page 23: ...s or a rectangular electri cal box The panel cable is 4 metres long and is fitted with connector B for con nection to the fan coil circuit board as shown in the wiring diagrams To install the wired co...

Reviews: