1508 - 5138800_00

ϭͳKEͬK&&

Turning the unit on and off.

ϮͳDK

Press this button to set the various operating modes: automatic (AUTO), 

cooling (COOL), heating (HEAT) and ventilation (FAN).

ϯͳ^>W

Press this button to enable the night comfort function (SLEEP).

ϰͳ<z

LOCK 

Press the 

 and MODE buttons for 3 seconds to activate or disactivate 

the key lock function.

The 

 LED will light up to show the key lock is activated.

ϱͳ>/^W>z

ϲͳ&E

Press this button to select the fan speed: automatic (AUTO), low (LOW), 

medium (MED) and high (HIGH).

ϳͲdDWZdhZΈΣΉ

Temperature control (16 to 30 °C).
Use these buttons to set the temperature you wish to have in the room, 

 to increase the temperature and 

 to decrease it.

ϴͳd/DZ

Timer control buttons (1 to 24 hours).
Use these buttons to set the time in hours, 

 to increase the time and 

 to decrease it.

WƌŽŐƌĂŵŵĞĚƚƵƌŶŝŶŐŽĨĨ͗

 with the fan coil unit on it sets and displays the operation time before the programmed turn off.

WƌŽŐƌĂŵŵĞĚƚƵƌŶŝŶŐŽŶ͗

with the fan coil unit off (but powered) it sets and displays the hours off before the programmed turn on.

ϵͲ^t/E'ͳ,KZ/KEd>>^

Press this button to control the vertical air flow. The first press starts the blades swinging. The second press stops the blades in the 

current position. To re-start the blades swinging press the SWING button again. 





/DWKZdEd
EŽƚĞĨŽƌ&tƐĞƌŝĞƐǁŝƚŚŵŝĐƌŽƉƌŽĐĞƐƐŽƌĐŽŶƚƌŽůůĞƌ͗
Ͳ dŚĞƚǁŽĐŽŶƚƌŽůƚLJƉĞƐ͕ǁŝƌĞĚĐŽŶƚƌŽůƉĂŶĞů;W&tϮͿĂŶĚƌĞŵŽƚĞĐŽŶƚƌŽů;d>tϮͿ͕ĐĂŶďĞƵƐĞĚĂƚƚŚĞƐĂŵĞƚŝŵĞŽŶƚŚĞƐĂŵĞĨĂŶ

coil unit. 

ʹ /ĨƚŚĞĨĂŶĐŽŝůŝƐŽĨĨ͕ĂůůƚŚĞƉƌĞǀŝŽƵƐƐĞƚƚŝŶŐƐŵĂĚĞĂƌĞŬĞƉƚŝŶƚŚĞŵĞŵŽƌLJĞdžĐĞƉƚĨŽƌƚŚĞd/DZƐĞƚƚŝŶŐĂŶĚ^>WŵŽĚĞ͘
ʹ /ĨƚŚĞĨĂŶĐŽŝůŝƐƚƵƌŶĞĚŽŶƵƐŝŶŐƚŚĞ;KEͬK&&ͿŬĞLJ͕ƚŚĞd/DZƐĞƚƚŝŶŐĂŶĚ^>WŵŽĚĞĂƌĞĐĂŶĐĞůůĞĚ͘

W&tϮͳ

WIRED CONTROL PANEL

>/ŶĚŝĐĂƚŝŽŶƐ
KƉĞƌĂƚŝŶŐŵŽĚĞ͗

COOL Cooling
DRY Dehumidification
HEAT Heating
FAN Ventilation

&ĂŶƐƉĞĞĚ͗

Display of the three fan speeds and the automatic control of the 

speed:

AUTO 

Automatic speed control

HIGH High 

speed

MED Medium 

speed

LOW Low 

speed

Functions:

TIMER 

Timer function is activated 

SWING 

Horizontal blades swinging

SLEEP 

Night comfort function activated

LOCK 

Keys are locked

>/^W>z

Temperature 

ΈΣΉ

Displays the value of the temperature set point in °C (from 16°C 

to 30°C)

Timer (hour)

Displays the value of hours (Hr) of the timer, when it is active.
With the fan coil unit on it displays the operation time before 

the programmed turn off.

With the fan coil unit off (but powered) it displays the hours off 

before the programmed turn on

 

/^W>zKEd,t/ZKEdZK>WE>

Summary of Contents for FCW Series

Page 1: ...42VLN IFCW3LJ 1508 5138800_00 IT GB FR DE ES pag 5 pag 26 pag 47 pag 68 pag 89 VENTILCONVETTORE PER INSTALLAZIONE A PARETE t DKhEd E K hE d s Ed K KEs d hZ WKhZ E d d KE DhZ GEBL SEKONVEKTOR F R WAND...

Page 2: ...egislaci n de armonizaci n pertinente de la Uni n CEIEN60335 2 40 2005 CEIEN60335 2 40 A1 2007 CEIEN55014 1 2008 CEIEN55014 2 1998 CEIEN61000 6 1 2007 CEIEN61000 6 3 2007 Soddisfacendo cos i requisiti...

Page 3: ...3 General information 34 Important information Operational limits 35 Direction of the air flow 36 Control keys and signals FCW with microprocessor controller 37 TLW2 Infra red remote control 38 PFW2 W...

Page 4: ...aged in transit If any anomalies are found immediately notify the haulier of the damage immediately notify the vendor of the damage t d The electric and electronic equipment must be handled separately...

Page 5: ...perations that involve dismantling of the fan coil unit or its components to ensure the maximum fan coil unit efficiency is restored Operations Internal cleaning annually or after long periods of inac...

Page 6: ...tions Several versions of FCW fan coil units are available in order to satisfy all types of installations with internal 2 way valve with internal 3 way valve without valve Each version is available Wi...

Page 7: ...all the operating parameters of the unit These parameters are shown on a liquid crystal dis play making programming operations easier The remote control is supplied with a bracket allowing it to be hu...

Page 8: ...ts again automatically with the same settings that it had at the time of stop ping with the exception of the Timer and Sleep settings DWKZd Ed E KZD d KE t ZE E d K d E t Regulations D hE d KE WKt Z d...

Page 9: ...0 V and ensure it remains within the limit of 10 with respect to the nominal value OPERATING ENVIRONMENT d of urban non marine atmosphere with non corrosive and non dusty h which the unit must operate...

Page 10: ...nually h d E d s Zd turn the vertical blades as indicated in the diagram both in heating or cooling mode it is advisable for the air flow not to hit people directly DKdKZ KZ KEd E cause a malfunction...

Page 11: ...5 C automatic ventila tion swinging blades Second press Heating with set point 22 C automatic venti lation swinging blades Third press Fan coil unit turned off t hy Set the operation mode Cooling Firs...

Page 12: ...f the horizontal blades Khs Z Press this button to regulate the vertical air flow with 4 fixed positions plus swinging blades E Press this button to transmit the parameters shown on the display to the...

Page 13: ...attery cover DWKZd Ed The two control types wired control panel and remote control can be used at the same time on the same fan coil unit The batteries have an average life of 10 months when used norm...

Page 14: ...off but powered it sets and displays the hours off before the programmed turn on t E KZ KEd Press this button to control the vertical air flow The first press starts the blades swinging The second pre...

Page 15: ...rameters shown on the LCD to the main control unit t d WW E t E d hdKD d WZK Z DD d With AUTO programme the control system decides the type of operation COOL or HEAT on the basis of the water and room...

Page 16: ...shown on the LCD to the main control unit 6 PFW2 TLW2 WZ d KE K OR z The fan coil comes on and the display is switched on WZ d DK z Press the MODE key repeatedly until the word FUN appears on the dis...

Page 17: ...If you wish to stop the blade in a particular position press the SWINGkey again WZ d E z d t To transmit the new parameters shown on the LCD to the main control unit d PFW2 TLW2 Tset 3 C Tset 2 C Tse...

Page 18: ...e control dK E d d D Z dd E TLW2 Press the key to cancel the timer setting PFW2 Press the TIMER key for 3 seconds to cancel the timer setting Press the or key to manually turn ON the unit while the ti...

Page 19: ...wn in the manual determined by the room temperature and humidity conditions These limits refer to unit operation with fan at minimum speed In order to avoid air stratification and therefore achieve be...

Page 20: ...on densate is connected to the sewage sys tem The service hole for the piping can be located on the right or left of the unit The support wall must be sturdy and not subject to vibrations Do not insta...

Page 21: ...Screws Screw covers nents of the unit paying attention that the debris from the materials used for the installation do not block the fan or obstruct the filters or the grilles After installation perfo...

Page 22: ...cable FCW_2V FCW_3V FCW_VL FCW_2VN FCW_3VN FCW_VLN IG 2A 1 5mm2 WARNING operations on the unit d ent circuit W s To protect the unit against short circuits s The electrical power cable must be of the...

Page 23: ...s or a rectangular electri cal box The panel cable is 4 metres long and is fitted with connector B for con nection to the fan coil circuit board as shown in the wiring diagrams To install the wired co...

Reviews: