64
Aermec code 6755530_03 9.2011
ANK 025-085H
TE
CHNICAL
SE
CTION
INS
TALLER
SE
CTION
USER
SE
CTION
Standards complied with
WHEN DESIGNING and MANUFAC
TURING the unit:
SAFETY
1. Machinery
Directive
2006/42/CE
2.
Low Voltage Directive
LVD 2006/95/CE
3. Electromagnetic
Compatibility
Directive EMC 2004/108/EC
4.
Directive regarding pressurised
devices
PED 97/23/CE, EN 378,
5. UNI12735,
UNI14276
ELECTRIC PART
1. IEC
EN
60335 2 40,
2. IEC
EN
61000 6 1/2/3/4
ACOUSTIC PART
1. ISO
DIS
9614/2
intensimetric method
PROTECTION RATING
IP24
EUROVENT EHPA
REFRIGERANT GAS
This unit contains fluoride gases with
greenhouse effect covered by the Kyoto
Protocol. Maintenance and disposal
must only be performed by qualified
staff, in compliance with standards in
force.
ATTENTION
1.
The refrigerant fluid circuit is
pressurised. Interventions must
only be performed on the appli-
ance by ATS (Authorised Technical
Service) or a qualified technician.
2. GAS
R410A
The chiller is delivered with
a sufficient amount of R410A
refrigerant fluid for operation. It
is a chlorine-free refrigerant fluid
that does not damage the ozone
layer. R410A is not inflammable.
However, all maintenance must
be performed exclusively by a
specialised technician with suit-
able protective equipment.
3.
Danger of electric shock!
The appliance must be
disconnected from the mains
power supply before the chiller
is opened.
18. GENERAL WARNINGS FOR THE INSTALLER
AERMEC ANK are constructed according to the ac-
knowledged technical standards and safety regulations.
They have been designed for air conditioning and the
production of domestic hot water (DHW) and must be
used compatibility with their technical features. Any
contractual or extracontractual liability of the Company
is excluded for injury/damage to persons, animals or
objects owing to installation, regulation and mainte-
nance errors or improper use. All uses not expressly
indicated in this manual are prohibited.
18.1. PRESERVATION OF THE DOCUMENTA
TION
1.
The instructions and all related documentation
must be given to the user of the system, who is
responsible for preserving the same so that they
are always on hand when required.
2.
Read this file carefully; the execution of all jobs
must be performed by qualified staff, according
to the Standards in force on this subject in the
different countries.
3.
The appliance warranty does not cover the
costs for ladders, scaffolding, or other elevation
systems that may become necessary for carrying
out servicing under warranty.
4.
Do not modify or tamper with the appliance as
dangerous situations can be created and the
manufacturer will not be liable for any damage
caused. The warranty shall be become null and
void if the above-mentioned indications are not
respected.
18.2. WARNINGS REGARDING SAFETY AND
INSTALLATION STANDARDS
1.
The appliance must be installed by a qualified
and suitably trained technician, in compliance
with the national legislation in force in the coun-
try of destination.
AERMEC will not assume any liability for damage
if these instructions are not respected.
2.
Before beginning any operation,
READ THESE
INSTRUCTIONS CAREFULLY AND CARRY OUT
THE SAFETY CHECKS IN ORDER TO REDUCE ALL
HAZARDS TO MINIMUM.
All the staff involved
must have thorough knowledge of the opera-
tions and any dangers that may arise at the
moment in which the installation operations are
carried out.