7. EHPA
400V/3N/50Hz TECHNICAL DATA
A 7/W 35
ANK020
ANK030
ANK040
ANK045
ANK050
ANK085
Hea ng capacity
H
kW
8.560
10.700
13.134
14.806
16.266
18.760
HP-HA
8.256
10.620
12.980
14.587
16.040
18.266
Input power
H
1.970
2.664
3.249
3.548
3.814
4.330
HP-HA
2.093
2.668
3.261
3.637
3.914
4.427
COP
H
W/W
4.345
4.017
4.042
4.173
4.265
4.333
HP-HA
3.945
3.981
3.980
4.011
4.098
4.126
Water flow rate
ALL
l/h
1470
1840
2260
2550
2800
3222
Pressure drops
H
kPa
28
16
24
18
22
27
Useful head pressure
HP-HA
55.0
63.0
51.0
74.3
65.7
56.2
Air flow rate
ALL
m
3
/h
3500
8000
8000
7500
7500
7500
Sound pressure
ALL
dB(A)
37.0
39.5
39.5
39.5
39.5
39.5
Sound power
ALL
68.0
70.5
70.5
70.5
70.5
70.5
A -7/W 35
ANK020
ANK030
ANK040
ANK045
ANK050
ANK085
Hea ng capacity
H
kW
4.810
5.872
7.300
8.136
9.524
10.480
HP-HA
4.897
5.748
7.208
7.936
9.316
10.364
Input power
H
1.850
2.573
3.102
3.334
3.596
4.030
HP-HA
1.926
2.612
3.121
3.422
3.696
4.160
COP
H
W/W
2.600
2.282
2.353
2.440
2.648
2.600
HP-HA
2.543
2.201
2.310
2.319
2.521
2.491
Water flow rate
ALL
l/h
1470
1840
2260
2550
2800
3222
Pressure drops
H
kPa
28
16
24
18
22
27
Useful head pressure
HP-HA
55.0
63.0
51.0
74.3
65.7
56.2
Air flow rate
ALL
m
3
/h
3500
8000
8000
7500
7500
7500
Sound pressure
ALL
dB(A)
37.0
39.5
39.5
39.5
39.5
39.5
Sound power
ALL
68.0
70.5
70.5
70.5
70.5
70.5
A 2/W 35
ANK020
ANK030
ANK040
ANK045
ANK050
ANK085
Hea ng capacity
H
kW
6.260
8.179
9.764
11.239
11.556
13.300
HP-HA
6.048
8.045
9.610
11.021
11.330
12.568
Input power
H
1.870
2.545
3.074
3.378
3.550
4.110
HP-HA
1.940
2.583
3.097
3.467
3.649
4.045
COP
H
W/W
3.348
3.214
3.176
3.327
3.255
3.236
HP-HA
3.118
3.115
3.103
3.179
3.105
3.107
Water flow rate
ALL
l/h
1470
1840
2260
2550
2800
3222
Pressure drops
H
kPa
28
16
24
18
22
27
Useful head pressure
HP-HA
55.0
63.0
51.0
74.3
65.7
56.2
Air flow rate
ALL
m
3
/h
3500
8000
8000
7500
7500
7500
Sound pressure
ALL
dB(A)
37.0
39.5
39.5
39.5
39.5
39.5
Sound power
ALL
68.0
70.5
70.5
70.5
70.5
70.5
Data in compliance with the EN 14511-2 Standard
Condenser inlet water temperature
30°C
Condenser outlet water temperature
35°C
External air temperature
7°C d.b./6° C w.b.
Sound power
Aermec determines sound power values on the basis of meas-
urements made in compliance with the ISO 9614-2 Standard,
in agreement with that requested by Eurovent certification.
Sound pressure
Sound pressure in free field conditions on reflective surface
(directivity factor Q=2) at 10 mt from the external surface of
unit, in compliance with ISO 3744 regulations.