4.2 Weather forecasting   

 

Sunny          Partly Cloudy      Cloudy              Rain

 
The four weather icons Sunny, Partly Cloudy, Cloudy and Rainy represent the short range (12-24 hours) 
weather  forecast.  The  weather  station  uses  air  pressure  patterns  to  predict  the  most  likely  upcoming 
weather, which can be quite different to the weather conditions  you are experiencing at the time (i.e. the 
forecast is not an indicator of current conditions, just look outside for that).   

 
4.3 Weather tendency indicator 

The  weather  tendency  indicator  arrows  are  located  between  the  weather  icons  to show  the  air  pressure 
tendency and provide a forecast of the weather to be expected due to increasing or decreasing air pressure. 
The  rightward  arrow  means  that  the  air  pressure  is  increasing  and  the  weather  is  expected  to  become 
better.  The  leftward  arrow  means  that  the  air  pressure  is  decreasing  and  the  weather  is  expected  to 
become worse. 
 
The change of the weather forecast icon is based on the relationship between current relative pressure and 
the pressure change within the last twelve hours. If the weather is changing, the weather tendency indicator 
(animated arrows) will be flashing. If after a three hour period the weather conditions have become stable, 
the arrows will fix indicating a stable condition.   
 

4.4 Examples of changing weather icons: 

 

         

 

 

4.5 Storm warning indicator 

 

The  storm  threshold 

can  be  set  to  suit  the  user’s  requirements  for  storm  forecasting  -  anywhere  from 

5-9hPa (default 4hPa). When there is a fall below the pressure threshold within any given 3 hour period the 
clouds  with  rain  icon  as  well  as  the  tendency  arrows  will  flash  for  3  hours  indicating  the  storm  warning 
feature has been activated. 

 

Notes on the pressure sensitivity setting for weather forecasting: 

 

The pressure threshold can be set to suit the user’s requirements for weather forecasting - anywhere from 
2-4hPa  (default  2hPa).  Areas  that  experience  frequent  changes  in  air  pressure  require  a  higher  setting 
compared to areas where the air pressure is more stable. For example if 4hPa is selected, then there must 
be a fall or rise in air pressure of at least 4hPa before the weather station will register this as a change in 
weather. 
 

5.  Program Mode 

The base station has five keys for easy operation: the 

SET

 key, 

ALARM

 key,

 MIN/MAX

 key 

+

 key and the 

SNOOZE/LIGHT

  key.  There  are  four  program  modes  available:  Quick  Display  Mode,  Setting  Mode, 

Alarm Mode and Min/Max Mode.

 

 
The program mode can be exited at any time by either pressing the 

SNOOZE/LIGHT

 key or waiting for 

the 10-second time-out to take effect. 
 
 

 

Summary of Contents for WS1173

Page 1: ...4 4 Examples of changing weather icons 6 4 5 Storm warning indicator 6 5 Program modes 6 5 1 Quick display mode 6 5 2 Setting mode 7 5 2 1 Setting Calibrated Humidity 8 5 2 2 Setting Barometric Pressure 8 5 3 Alarm mode 9 5 4 Min Max mode 9 6 Trouble Shooting 10 7 Specifications 10 8 Contact Information 11 This Operation Manual is part of this product and should be kept in a safe place for future ...

Page 2: ... our local distributor Greenfrog Scientific www greenfrogscientific co uk and their team will be happy to help Genuine faults can typically be diagnosed without requiring the unit to be returned and replacement parts sent quickly if needed Purchased in AUSTRALIA As many issues can be a result of incorrect setup please contact our local distributor Monax Test Weather www monaxtestandweather com au ...

Page 3: ...cation Every time the remote sensor is powered up for example after a change of batteries a random security code is transmitted and this code must be synchronised with the base station to receive weather data Thus if the batteries have been changed on the transmitter then the receiver must be powered up again to re learn the transmitter code After the remote sensor is powered up the sensor will tr...

Page 4: ...s Never dispose of batteries in a fire as this may cause an explosion risk of fire or leakage of dangerous chemicals and fumes 3 2 Mounting 1 Base station With one foldable leg at the back of the unit the base station can be placed onto any flat surface or wall mounted at the desired location by the hanging holes also at the back of the unit It is important to check that outdoor sensor data can be...

Page 5: ...ature display unit 12 Indoor temperature and humidity alarm on indicator 13 Remote sensor transmit signal indicator 14 MIN MAX information 15 Dew point temperature display 16 Outdoor humidity display 17 Outdoor temperature and humidity low alarm and high alarm 18 Temperature display unit 19 Outdoor temperature display 20 General outdoor alarm icon 21 Weather forecast icon 22 Weather tendency indic...

Page 6: ... period the weather conditions have become stable the arrows will fix indicating a stable condition 4 4 Examples of changing weather icons 4 5 Storm warning indicator The storm threshold can be set to suit the user s requirements for storm forecasting anywhere from 5 9hPa default 4hPa When there is a fall below the pressure threshold within any given 3 hour period the clouds with rain icon as well...

Page 7: ...elative pressure setting from 919 0hPa 1080 0hPa default 1013 5hPa 10 Pressure threshold setting default 2hPa 11 Storm threshold setting default 4hPa In the setting mode press the key or MIN MAX key to change or scroll the value Holding the key or MIN MAX key for 3 seconds will increase decrease the digits faster Press the SNOOZE LIGHT key or no keys for 10 seconds the setting mode will return to ...

Page 8: ...evel corrected pressure the pressure your location would be at if located at sea level is generally higher than your measured pressure To determine the relative pressure for your location locate an official reporting station near you the internet is the best source for real time barometer conditions such as Weather com or Wunderground com and set your weather station to match the official reportin...

Page 9: ... flash accordingly For example in the outdoor temperature display mode when the dew point high alarm is triggered the DEW POINT icon will flash along with the general outdoor alarm icon and high alarm icon telling the user that the current alarm source is from the dew point 5 4 Min Max Mode While in Normal Mode press the MIN MAX key to enter the Maximum Mode the MAX logo and the general maximum re...

Page 10: ... reinsert the batteries and wait for a few minutes to see whether the signal is picked up Check for sources of interference cordless phones baby monitors PC monitors etc If this is an issue the console and or transmitter will need to be relocated If none of these is causing the problem you may have a faulty transmitter 7 Specifications Outdoor data Transmission distance in open field 100meter max ...

Page 11: ... parts sent quickly if needed Purchased in NEW ZEALAND Please contact our local distributor Scientific Sales www scientificsales co nz and their team will be happy to help Genuine faults can typically be diagnosed without requiring the unit to be returned and replacement parts sent quickly if needed For all others please contact the retailer who sold you this item EU DECLARATION OF CONFORMITY Here...

Reviews: