background image

 

 

- 7 - 

5.1 Quick Display Mode 

While in Normal Mode, press the 

SET

 key to enter the Quick Display Mode as follows: 

1.    Outdoor Temperature / Dew  Point - press the 

MIN/MAX

 key or 

+

 key to shift the display  between 

outdoor temperature and dew point). 

2.    Absolute  Pressure  /  Relative  Pressure  -  press  the 

MIN/MAX

  key  or 

+

  key  to  shift  the  display 

between the absolute pressure and relative pressure). 

 
Press the 

SET

 key to accept the change and advance to the next display mode. Continue to press the 

SET

 key to toggle through the display mode until returning to Normal Mode. 

 

5.2 Setting Mode 

Press the 

SET

 key for 3 seconds while in Normal Mode to enter the Setting Mode.

 

Press the 

SET

 key to select the following settings in sequence: 

1. 

Time zone 

2. 

12/24 hour format 

3. 

Manual time setting (hours / minutes) 

4. 

Calendar setting (year / month / date) 

5. 

Temperature display unit in degrees Celsius or Fahrenheit 

6. 

Indoor humidity calibration 

7. 

Outdoor humidity calibration   

8. 

Air pressure display units in hPa or inHg 

9. 

Relative pressure setting from 919.0hPa 

– 1080.0hPa (default 1013.5hPa) 

10.  Pressure threshold setting (default 2hPa) 
11.  Storm threshold setting (default 4hPa) 

 

In the setting mode, press the 

+

 key or 

MIN/MAX

 key to change or scroll the value. Holding the 

key or 

MIN/MAX

 key for 3 seconds will increase/decrease the digits faster. Press the 

SNOOZE/LIGHT

 key or no 

keys for 10 seconds, the setting mode will return to Normal Mode. 
 

Note: 

Please set the units first before changing the corresponding 

unit’s value. When changing between 

units the previous set value will be changed according to the new units. This may cause resolution loss 
due to the internal calculation algorithm. 
 

Note: 

The radio controlled clock (RCC) works off the German DCF77 time signal received across large 

parts of Europe and the UK so set your time zone as follows:   

 

Country 

Time Zone 

 

Country 

Time Zone 

Iceland (-2 for German DST) 

-1   

 

Poland 

Ireland 

-1 

 

Slovakia 

Portugal 

-1 

 

Spain 

United Kingdom 

-1 

 

Sweden 

Albania 

 

Switzerland 

Austria 

 

Bulgaria 

+1 

Belgium 

 

Estonia 

+1 

Croatia 

 

Finland 

+1 

Denmark 

 

Greece 

+1 

France 

 

Latvia 

+1 

Germany 

 

Lithuania 

+1 

Hungary 

 

Moldova 

+1 

Italy 

 

Romania 

+1 

Netherlands 

 

Turkey 

+1 

Norway 

 

Ukraine 

+1 

 
 
 

Summary of Contents for WS1173

Page 1: ...4 4 Examples of changing weather icons 6 4 5 Storm warning indicator 6 5 Program modes 6 5 1 Quick display mode 6 5 2 Setting mode 7 5 2 1 Setting Calibrated Humidity 8 5 2 2 Setting Barometric Pressure 8 5 3 Alarm mode 9 5 4 Min Max mode 9 6 Trouble Shooting 10 7 Specifications 10 8 Contact Information 11 This Operation Manual is part of this product and should be kept in a safe place for future ...

Page 2: ... our local distributor Greenfrog Scientific www greenfrogscientific co uk and their team will be happy to help Genuine faults can typically be diagnosed without requiring the unit to be returned and replacement parts sent quickly if needed Purchased in AUSTRALIA As many issues can be a result of incorrect setup please contact our local distributor Monax Test Weather www monaxtestandweather com au ...

Page 3: ...cation Every time the remote sensor is powered up for example after a change of batteries a random security code is transmitted and this code must be synchronised with the base station to receive weather data Thus if the batteries have been changed on the transmitter then the receiver must be powered up again to re learn the transmitter code After the remote sensor is powered up the sensor will tr...

Page 4: ...s Never dispose of batteries in a fire as this may cause an explosion risk of fire or leakage of dangerous chemicals and fumes 3 2 Mounting 1 Base station With one foldable leg at the back of the unit the base station can be placed onto any flat surface or wall mounted at the desired location by the hanging holes also at the back of the unit It is important to check that outdoor sensor data can be...

Page 5: ...ature display unit 12 Indoor temperature and humidity alarm on indicator 13 Remote sensor transmit signal indicator 14 MIN MAX information 15 Dew point temperature display 16 Outdoor humidity display 17 Outdoor temperature and humidity low alarm and high alarm 18 Temperature display unit 19 Outdoor temperature display 20 General outdoor alarm icon 21 Weather forecast icon 22 Weather tendency indic...

Page 6: ... period the weather conditions have become stable the arrows will fix indicating a stable condition 4 4 Examples of changing weather icons 4 5 Storm warning indicator The storm threshold can be set to suit the user s requirements for storm forecasting anywhere from 5 9hPa default 4hPa When there is a fall below the pressure threshold within any given 3 hour period the clouds with rain icon as well...

Page 7: ...elative pressure setting from 919 0hPa 1080 0hPa default 1013 5hPa 10 Pressure threshold setting default 2hPa 11 Storm threshold setting default 4hPa In the setting mode press the key or MIN MAX key to change or scroll the value Holding the key or MIN MAX key for 3 seconds will increase decrease the digits faster Press the SNOOZE LIGHT key or no keys for 10 seconds the setting mode will return to ...

Page 8: ...evel corrected pressure the pressure your location would be at if located at sea level is generally higher than your measured pressure To determine the relative pressure for your location locate an official reporting station near you the internet is the best source for real time barometer conditions such as Weather com or Wunderground com and set your weather station to match the official reportin...

Page 9: ... flash accordingly For example in the outdoor temperature display mode when the dew point high alarm is triggered the DEW POINT icon will flash along with the general outdoor alarm icon and high alarm icon telling the user that the current alarm source is from the dew point 5 4 Min Max Mode While in Normal Mode press the MIN MAX key to enter the Maximum Mode the MAX logo and the general maximum re...

Page 10: ... reinsert the batteries and wait for a few minutes to see whether the signal is picked up Check for sources of interference cordless phones baby monitors PC monitors etc If this is an issue the console and or transmitter will need to be relocated If none of these is causing the problem you may have a faulty transmitter 7 Specifications Outdoor data Transmission distance in open field 100meter max ...

Page 11: ... parts sent quickly if needed Purchased in NEW ZEALAND Please contact our local distributor Scientific Sales www scientificsales co nz and their team will be happy to help Genuine faults can typically be diagnosed without requiring the unit to be returned and replacement parts sent quickly if needed For all others please contact the retailer who sold you this item EU DECLARATION OF CONFORMITY Here...

Reviews: