10.16 Burner Start-Up
Burner Start-Up
1. Turn on electricity to the burner by turning the power switch on the boiler panel to ON.
2. Close the thermostats and pressure switches. Please refer to the appropriate manual for
instructions to perform this operation.
3. Turn the switch shown in Figure 10-13 to the
“LOCAL”
position and turn the other switch
“
OIL
” for oil operation or “
GAS
” for gas operation.
Figure 10-13: Burner Controls Used for Startup
DANGER!
Make sure that the lamps or testers connected to the solenoids, or indicator lights on the
solenoids themselves, show that no voltage is present. If voltage is present, stop the burner
immediately
and check the electrical wiring.
NOTE:
For the start-up procedure and the parameters calibration, refer to the specific instruction
manual of the LMV37 electronic cam supplied with the burner.
DIRECTION
OF MOTOR
ROTATION