AEQ
TALENT
32
4.6. Ethernet
Port configuration.
The "
Ethernet config
" menu allows for the configuration of the unit’s Ethernet interface IP
parameters.
The parameters to be configured are:
-
Enable DHCP:
enables the activation or deactivation of the automatic IP address, mask
and gateway configuration. There must be a DHCP server in the network the unit is
connected to in order for this option to work. When "Enable DHCP" is active, the
following parameters will be filled automatically; when "Enable DHCP" is not active, you
will be able to change them manually.
-
IP Address:
valid IP address associated with that interface.
-
Subnet mask:
valid subnet mask associated with that interface.
-
Gateway IP:
valid gateway or network gateway address associated with that interface.
-
DNS Server:
IP address of the external addresses resolution server, valid in the
geographic zone where codec is placed, or internal server (inside the local network)
authorized to translate alphanumeric URL identifiers into IP addresses.
Once those parameters are configured, and after clicking on the "Apply" button, a confirmation
window will appear. After confirming, the equipment reboots and the communication re-
establishes in approximately 15 seconds.
If you have any doubts, please consult your IT network technician or directly contact AEQ or
authorized distributors’ technical support department.
4.7. SNMP configuration.
This unit can be remotely managed using SNMP (Simple Network Management Protocol) using
one of the many software clients available in the market, even for free. SNMP allows for
monitoring of the status of several pieces of equipment from very diverse manufacturers and
natures, as well as elaborating reports, generate e-mail alerts, etc.
You can access the configuration menu in "Configuration"
"Network".