background image

 

Parameter 

Number 

Hex / Decimal 

Description 

Default Value 

Size 

2  (0x02) 

Enable/Disable waking up for 10 minutes when re-power on (battery mode) the 

MultiSensor. 

1. Value = 0, disable. 

2. Value =others, enable. 

3 (0x03) 

1. The default PIR time is 4 minutes. The Multisensor will send BASIC SET CC 

(0x00) to the associated nodes if no motion is triggered again in 4 minutes. 

2. Range: 10~3600. 

Note: 

(1), The time unit is second if the value range is in 10 to 255.  

(2), If the value range is in 256 to 3600, the time unit will be minute and its value 

should follow the below rules: 
a),  Interval time =Value/60, if the interval time can be divided by 60 and 

without remainder. 

b), Interval time= (Value/60) +1, if the interval time can be divided by 60 and 

has remainder. 

(3), Other values will be ignored. 

240 

 4 (0x04) 

Enable/disable the function of motion sensor. 

1. Value=0, disable. 

2. Value=1, enable, the current PIR sensitivity level=1. (minimum level) 

 Value=2, enable, the current PIR sensitivity level=2.   

Value=3, enable, the current PIR sensitivity level=3.   

Value=4, enable, the current PIR sensitivity level=4.   

Value=5, enable, the current PIR sensitivity level=5. (maximum level) 

 5 (0x05) 

Which command would be sent when the motion sensor triggered. 

1. Value=1, send Basic Set CC. 

2. Value=2, send Sensor Binary Report CC. 

 39 (0x27) 

Configure low battery value. 

Value=10 to 50.(10% to 50%) 

20 (%) 

 40 (0x28) 

Enable/disable the selective reporting only when measurements reach a certain 

threshold or percentage set in 41-44 below.  This is used to reduce network 

traffic.  (0 == disable, 1 == enable) 

 41 (0x29) 

Threshold change in temperature to induce an automatic report.  

Note: 

1. The unit is Fahrenheit for US version, Celsius for EU/AU version. 

2. The value contains one decimal point. E.g. if the value is set to 20, the 

threshold value =2.0 

 (EU/AU version) or 2.0 

℉ 

(US version). When the 

current temperature gap is more then 2.0, which will induce a temperature 

report to be sent out. 

20 

 42 (0x2A) 

Threshold change in humidity to induce an automatic report. 

Note: 

1.

 

The unit is %. 

2.

 

The default value is 10, which means that if the current humidity gap is 

more than 10%, it will send out a humidity report. 

10 

Summary of Contents for MultiSensor 6

Page 1: ...Aeon Labs MultiSensor 6 Z wave MultiSensor...

Page 2: ...Change history Revision Date Change Description 1 9 23 2014 Initial draft 2 5 26 2015 Update 3 7 01 2015 Update 4 7 21 2015 Update V1 06 5 8 11 2015 Add more details for configuration parameters...

Page 3: ...t motion again The Multisensor will send basic set 0x00 if the PIR motion sensor is not triggered for the interval time configurable As soon as MultiSensor is removed from a z wave network it will res...

Page 4: ...ng temperature 0 to 40 Relative humidity 8 RH to 80 RH 3 Familiarize Yourself with Your MultiSensor 3 1 Interface 4 All Functions of Each Trigger 4 1 Function of Z Wave Button Trigger Description Clic...

Page 5: ...n mode If you don t know how to do this refer to its manual 3 Press the Action Button 4 If the exclusion is success MultiSensor s LED will blink slowly when you short press the Action Button If MultiS...

Page 6: ...Group 1 Lifeline 5 3 3 Association Group Command List Report Command List Report 20 01 30 03 80 03 31 05 71 05 84 07 COMMAND_CLASS_BASIC BASIC_SET COMMAND_CLASS_SENSOR_BINARY SENSOR_BINARY_REPORT COMM...

Page 7: ...ue 3 enable the current PIR sensitivity level 3 Value 4 enable the current PIR sensitivity level 4 Value 5 enable the current PIR sensitivity level 5 maximum level 5 1 5 0x05 Which command would be se...

Page 8: ...ich report needs to be sent in Report group 3 See flags in table below 0 4 110 0x6E Set 111 113 to default 111 0x6F The interval time of sending reports in Report group 1 Valid values 0x05 0x28DE80 1...

Page 9: ...Humidity sensor calibration the available value range is 50 50 The calibration value standard value measure value E g If measure value 80RH and the standard value 75RH so the calibration value 75RH 80...

Page 10: ...Reserved configuration Value 2 Reserved configuration Value 3 Reserved configuration Value 4 LSB Luminance Humidity Temperature Ultraviolet Reserved Reserved Reserved Battery Reserved Reserved bits or...