 43 (0x2B) 

Threshold change in luminance to induce an automatic report. 

100 (LUX) 

 44 (0x2C) 

Threshold change in battery level to induce an automatic report. 

Note: 

1.

 

The unit is %. 

2.

 

The default value is 10, which means that if the current battery level gap is 

more than 10%, it will send out a battery report. 

10 (%) 

45 (0x2D) 

Threshold change in ultraviolet to induce an automatic report. 

 46 (0x2E) 

Enable/disable to send the alarm report of low temperature(<-15

Value=0, disable. 

Value=1, enable (The MultiSensor will send a report of Multi Level Temperature 

CC to controller if the current temperature is less than -15

). 

Note: The battery activity will be reduced at low temperatures (-15 degrees 

Celsius and below), which will lead to the product may not work normally. It is 

recommended to use USB power at low temperatures. 

100 (0x64) 

Set 101-103 to default. 

101 (0x65) 

Which report needs to be sent in Report group 1 (See flags in table below). 

241 

102 (0x66) 

Which report needs to be sent in Report group 2 (See flags in table below). 

103 (0x67) 

Which report needs to be sent in Report group 3 (See flags in table below). 

110 (0x6E) 

Set 111-113 to default. 

111 (0x6F) 

The interval time of sending reports in Report group 1 (Valid values 0x05-

0x28DE80). 

1. The unit of interval time is second if USB power. 

2. If battery power, the minimum interval time is 60 minutes by default,  for 

example, if the value is set to be more than 5 and less than 3600, the interval 

time is 60 minutes, if the value is set to be more than 3600 and less than 7200, 

the interval time is 120 minutes. You can also change the minimum interval time 

to 4 minutes via setting the interval value(3 bytes) to 240 in Wake Up Interval Set 

CC.  

3600 (seconds) 

112 (0x70) 

The interval time of sending reports in Report group 2 (Valid values 0x05-

0x28DE80). 

Note: 

 1. The unit of interval time is second if USB power. 

2. If battery power, the minimum interval time is 60 minutes by default,  for 

example, if the value is set to be more than 5 and less than 3600, the interval 

time is 60 minutes, if the value is set to be more than 3600 and less than 7200, 

the interval time is 120 minutes. You can also change the minimum interval time 

to 4 minutes via setting the interval value(3 bytes) to 240 in Wake Up Interval Set 

CC. 

3600 (seconds) 

Summary of Contents for MultiSensor 6

Page 1: ...Aeon Labs MultiSensor 6 Z wave MultiSensor...

Page 2: ...Change history Revision Date Change Description 1 9 23 2014 Initial draft 2 5 26 2015 Update 3 7 01 2015 Update 4 7 21 2015 Update V1 06 5 8 11 2015 Add more details for configuration parameters...

Page 3: ...t motion again The Multisensor will send basic set 0x00 if the PIR motion sensor is not triggered for the interval time configurable As soon as MultiSensor is removed from a z wave network it will res...

Page 4: ...ng temperature 0 to 40 Relative humidity 8 RH to 80 RH 3 Familiarize Yourself with Your MultiSensor 3 1 Interface 4 All Functions of Each Trigger 4 1 Function of Z Wave Button Trigger Description Clic...

Page 5: ...n mode If you don t know how to do this refer to its manual 3 Press the Action Button 4 If the exclusion is success MultiSensor s LED will blink slowly when you short press the Action Button If MultiS...

Page 6: ...Group 1 Lifeline 5 3 3 Association Group Command List Report Command List Report 20 01 30 03 80 03 31 05 71 05 84 07 COMMAND_CLASS_BASIC BASIC_SET COMMAND_CLASS_SENSOR_BINARY SENSOR_BINARY_REPORT COMM...

Page 7: ...ue 3 enable the current PIR sensitivity level 3 Value 4 enable the current PIR sensitivity level 4 Value 5 enable the current PIR sensitivity level 5 maximum level 5 1 5 0x05 Which command would be se...

Page 8: ...ich report needs to be sent in Report group 3 See flags in table below 0 4 110 0x6E Set 111 113 to default 111 0x6F The interval time of sending reports in Report group 1 Valid values 0x05 0x28DE80 1...

Page 9: ...Humidity sensor calibration the available value range is 50 50 The calibration value standard value measure value E g If measure value 80RH and the standard value 75RH so the calibration value 75RH 80...

Page 10: ...Reserved configuration Value 2 Reserved configuration Value 3 Reserved configuration Value 4 LSB Luminance Humidity Temperature Ultraviolet Reserved Reserved Reserved Battery Reserved Reserved bits or...

Reviews: