3. Remove MultiSensor from Z-wave network: 

1. Power on MultiSensor. The MultiSensor’s LED will be kept turning on for 8 seconds when you short press 

the Action Button. 

2. Let the primary controller into exclusion mode (If you don’t know how to do this, refer to its manual). 

3. Press the Action Button. 

4. If the exclusion is success, MultiSensor’s LED will blink slowly when you short press the Action Button. If 

MultiSensor’s LED still keeps on status, in which you need to repeat the process from step 2. 

Short press 2 times 

within 1 second 

1. Send Security Node Info frame. 

2. Add MultiSensor into z-wave network: 

1. Power on MultiSensor. The MultiSensor’s LED will blink slowly when you short press the Action Button. 

2. Let the primary controller into inclusion mode (If you don’t know how to do this, refer to its manual). 

3. Press the Action Button. 

4. If the inclusion is success, MultiSensor’s LED will be kept turning on for 8 seconds when you short press the 

Action Button. If the LED is still in slow blink, in which you need to repeat the process from step 2. 

 

3. Remove MultiSensor from Z-wave network: 

1. Power on MultiSensor. The MultiSensor’s LED will be kept turning on for 8 seconds when you short press 

the Action Button. 

2. Let the primary controller into exclusion mode (If you don’t know how to do this, refer to its manual). 

3. Press the Action Button. 

4. If the exclusion is success, MultiSensor’s LED will blink slowly when you short press the Action Button. If 

MultiSensor’s LED still keeps on status, in which you need to repeat the process from step 2.

 

Press and hold for 3 

seconds 

Enable/disable wake up for 10 minutes. 

(When it is enabled, the orange Led will fast blink) 

Press and hold for 

20 seconds 

Reset MultiSensor to factory Default: 

1. Press and hold the Action Button for 20 seconds. 

2. If holding time more than one second, the LED will blink faster and faster. If holding time more than 20 

seconds, the LED will be on for 2 seconds, which indicates reset is success, otherwise please repeat step 2. 

Note: 

1, This procedure should only be used when the primary controller is inoperable.  

2, Reset MultiSensor to factory default settings, it will:  

a ), let the MultiSensor to be excluded in Z-Wave network;  

b), delete the Association setting, power measure value, Scene Configuration settings; 

c), restore the Configuration settings to the default. 

 

 

 

5. Special Rule of Each Command 

5.1 Z-Wave Plus Info Report Command Class 

Parameter 

Value 

Z-Wave Plus Version  

Role Type  

6(ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_ON) 

Node Type  

0 (ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE) 

Installer Icon Type  

0x0C07 (ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_HOME_SECURITY) 

User Icon Type  

0x0C07 (ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_HOME_SECURITY) 

 

Summary of Contents for MultiSensor 6

Page 1: ...Aeon Labs MultiSensor 6 Z wave MultiSensor...

Page 2: ...Change history Revision Date Change Description 1 9 23 2014 Initial draft 2 5 26 2015 Update 3 7 01 2015 Update 4 7 21 2015 Update V1 06 5 8 11 2015 Add more details for configuration parameters...

Page 3: ...t motion again The Multisensor will send basic set 0x00 if the PIR motion sensor is not triggered for the interval time configurable As soon as MultiSensor is removed from a z wave network it will res...

Page 4: ...ng temperature 0 to 40 Relative humidity 8 RH to 80 RH 3 Familiarize Yourself with Your MultiSensor 3 1 Interface 4 All Functions of Each Trigger 4 1 Function of Z Wave Button Trigger Description Clic...

Page 5: ...n mode If you don t know how to do this refer to its manual 3 Press the Action Button 4 If the exclusion is success MultiSensor s LED will blink slowly when you short press the Action Button If MultiS...

Page 6: ...Group 1 Lifeline 5 3 3 Association Group Command List Report Command List Report 20 01 30 03 80 03 31 05 71 05 84 07 COMMAND_CLASS_BASIC BASIC_SET COMMAND_CLASS_SENSOR_BINARY SENSOR_BINARY_REPORT COMM...

Page 7: ...ue 3 enable the current PIR sensitivity level 3 Value 4 enable the current PIR sensitivity level 4 Value 5 enable the current PIR sensitivity level 5 maximum level 5 1 5 0x05 Which command would be se...

Page 8: ...ich report needs to be sent in Report group 3 See flags in table below 0 4 110 0x6E Set 111 113 to default 111 0x6F The interval time of sending reports in Report group 1 Valid values 0x05 0x28DE80 1...

Page 9: ...Humidity sensor calibration the available value range is 50 50 The calibration value standard value measure value E g If measure value 80RH and the standard value 75RH so the calibration value 75RH 80...

Page 10: ...Reserved configuration Value 2 Reserved configuration Value 3 Reserved configuration Value 4 LSB Luminance Humidity Temperature Ultraviolet Reserved Reserved Reserved Battery Reserved Reserved bits or...