Aeon Labs MultiSensor 6 

Engineering Specifications and Advanced Functions for Developers 

 

Aeon Labs MultiSensor is a routing binary sensor device based on Z-Wave routing slave library V6.51.06.  
 
MultiSensor can be included and operated in any Z-wave network with other Z-wave certified devices 
from other manufacturers and/or other applications. All non-battery operated nodes within the network 
will act as repeaters regardless of vendor to increase reliability of the network.  
 
It also supports Security Command Class and has the AES-128 bit security encryption built right in. While 
a Security enabled Controller is needed in order to fully use the security feature.  
 
If the MultiSensor is included into a SIS or SUC Z-wave network, it will be associated to SIS or SUC 
automatically.  
If PIR motion sensor is triggered, the MultiSensor will send a Basic set (0xFF) to associated devices.  The 
PIR motion sensor will then become inactive. After an interval time (configurable), the PIR motion 
sensor will wake up and can detect motion again. The Multisensor will send basic set (0x00) if the PIR 
motion sensor is not triggered for the interval time (configurable).  
 
As soon as MultiSensor is removed from a z-wave network it will restore itself into factory settings. 
 

1. Library and Command Classes 

1.1 SDK: 

6.51.06

 

1.2 Library 

 

Basic Device Class:

 BASIC_TYPE_ROUTING_SLAVE

 

 

Generic Device class:

 GENERIC_TYPE_ SENSOR_MULTILEVEL 

 

Specific Device Class: SPECIFIC_TYPE_ ROUTING_MULTILEVEL_SENSOR 

1.3 Commands Class 

    

Included Non-Secure 

Included Secure 

Node Info Frame 

COMMAND_CLASS_ZWAVEPLUS_INFO V2, 

COMMAND_CLASS_VERSION V2, 

COMMAND_CLASS_MANUFACTURER_SPECIFIC, 

COMMAND_CLASS_ASSOCIATION_GRP_INFO, 

COMMAND_CLASS_ASSOCIATION V2, 

COMMAND_CLASS_POWERLEVEL V1, 

COMMAND_CLASS_NOTIFICATION_V3, 

COMMAND_CLASS_WAKE_UP V2, 

COMMAND_CLASS_BATTERY V1, 

COMMAND_CLASS_SENSOR_BINARY V1, 

COMMAND_CLASS_SENSOR_MULTILEVEL_V5, 

COMMAND_CLASS_CONFIGURATION V1, 

COMMAND_CLASS_SECURITY V1, 

COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2,, 

COMMAND_CLASS_MARK, 

COMMAND_CLASS_DEVICE_RESET_LOCALLY, 

COMMAND_CLASS_ZWAVEPLUS_INFO V2 

COMMAND_CLASS_VERSION V2 

COMMAND_CLASS_WAKE_UP V2 

COMMAND_CLASS_MANUFACTURER_SPECIFIC V2 

COMMAND_CLASS_SECURITY V1 

COMMAND_CLASS_DEVICE_RESET_LOCALLY V1 

COMMAND_CLASS_MARK V1 

Summary of Contents for MultiSensor 6

Page 1: ...Aeon Labs MultiSensor 6 Z wave MultiSensor...

Page 2: ...Change history Revision Date Change Description 1 9 23 2014 Initial draft 2 5 26 2015 Update 3 7 01 2015 Update 4 7 21 2015 Update V1 06 5 8 11 2015 Add more details for configuration parameters...

Page 3: ...t motion again The Multisensor will send basic set 0x00 if the PIR motion sensor is not triggered for the interval time configurable As soon as MultiSensor is removed from a z wave network it will res...

Page 4: ...ng temperature 0 to 40 Relative humidity 8 RH to 80 RH 3 Familiarize Yourself with Your MultiSensor 3 1 Interface 4 All Functions of Each Trigger 4 1 Function of Z Wave Button Trigger Description Clic...

Page 5: ...n mode If you don t know how to do this refer to its manual 3 Press the Action Button 4 If the exclusion is success MultiSensor s LED will blink slowly when you short press the Action Button If MultiS...

Page 6: ...Group 1 Lifeline 5 3 3 Association Group Command List Report Command List Report 20 01 30 03 80 03 31 05 71 05 84 07 COMMAND_CLASS_BASIC BASIC_SET COMMAND_CLASS_SENSOR_BINARY SENSOR_BINARY_REPORT COMM...

Page 7: ...ue 3 enable the current PIR sensitivity level 3 Value 4 enable the current PIR sensitivity level 4 Value 5 enable the current PIR sensitivity level 5 maximum level 5 1 5 0x05 Which command would be se...

Page 8: ...ich report needs to be sent in Report group 3 See flags in table below 0 4 110 0x6E Set 111 113 to default 111 0x6F The interval time of sending reports in Report group 1 Valid values 0x05 0x28DE80 1...

Page 9: ...Humidity sensor calibration the available value range is 50 50 The calibration value standard value measure value E g If measure value 80RH and the standard value 75RH so the calibration value 75RH 80...

Page 10: ...Reserved configuration Value 2 Reserved configuration Value 3 Reserved configuration Value 4 LSB Luminance Humidity Temperature Ultraviolet Reserved Reserved Reserved Battery Reserved Reserved bits or...

Reviews: