background image

09

08

Setting Mode

Temperature

1

2

3

4

5

6

7

8

9

+/-

0

.

CLR

DEL

Enter

15.0

38.0

25.0

25.0

OFF

OFF

OFF

OFF

OFF

30.0

50

1500

3

Auto

0

0

1

9

8

+

-

Humidity

1

2

3

4

5

6

7

8

9

+/-

0

.

CLR

DEL

Enter

25.0

50.0

30.0

25.0

OFF

OFF

OFF

OFF

OFF

30.0

50

1500

3

Auto

0

0

1

9

8

+

-

1. Temperature Setting

 

a) Enter “Setting Mode”.

b) Click the existing temperature figure in “Tempera-

ture” bar. 

c) Set the desired temperature by clicking the numbers in the 

newly opened settings box, within the range of 15 -38 Celsius 

Degrees (59 -100.5 Fahrenheit).

d) Click “Enter” to set and save the new value, and then click 

the “X” in the top right corner of the settings box to close the 

settings box.

2. Humidity Setting 

a) Enter “Setting Mode”.

b) Click the existing humidity figure in “Humidity” bar. 

c) Set the desired humidity by clicking the numbers in the 

newly opened settings box, within the range of 25 -50%, click 

the “X” in the top right corner of the settings box to close the 

settings box. 

Temperature

Humidity

3. Oxygen Density Setting

a) Enter “Setting Mode”.

b) Click the existing oxygen figure in “O

2

 Density” bar.

c) Input the desired oxygen density value by clicking the newly 

opened setting box, within the range of 21 -65%.

d) Click “Enter” to set the new oxygen level, click the “X” in the 

top right corner of the Settings box to close the settings box. 

4. Carbon Dioxide Density Set

a) Enter “Setting Mode”.

b) Click the existing carbon dioxide figure in “CO

2

 Density” bar.

c) Input the desired carbon dioxide density by clicking the 

newly displayed setting box, within the range of 200 

-2000ppm.

d) Click “Enter” to set the new carbon dioxide level, click the 

“X” in the top right corner of the settings box to close the 

settings box.

5. Illumination Light Set

a) Enter “Setting Mode”.

b) Click the existing time figure in “Light Timer” bar.

c) Input the desired working time for illumination light by 

clicking the newly displayed setting box, within the range of 1 

-360 minutes.

d) Click “Enter” to set the illumination light working time, click 

the “X” in the top right corner of the settings box to close the 

settings box. 

6. Light Brightness Set

On “Setting Mode” interface, the light brightness can be 

adjusted by pressing either “+” or “-“ button on “Light 

Brightness” bar, displayed in the graph here.

Once the level of brightness is set, illumination light will start.

7. Ventilation Fan Control

a) Enter “Setting Mode”.

b) Click the existing fan speed on “Fan Speed” bar, to shift 

fan speed through “high”, “middle” and “low”.

O

2

 Density

1

2

3

4

5

6

7

8

9

+/-

0

.

CLR

DEL

Enter

21

65

50

25.0

30.0

50

1500

3

Auto

+

-

CO2 Density

1

2

3

4

5

6

7

8

9

+/-

0

.

CLR

DEL

Enter

200

2000

1500

25.0

30.0

50

1500

3

Auto

+

-

Light Timer

1

2

3

4

5

6

7

8

9

+/-

0

.

CLR

DEL

Enter

0

360

3

+

-

25.0

30.0

50

1500

3

Auto

+

-

25.0
30.0

50

1500

3

Auto

+

-

O

2

 Density

CO

2

 Density

Light Brightness

Fan Speed

Light Timer

Remarks: Fan running speed will affect heating or cooling efficiency, please make decisions 

according to actual needs based on animal patients status and ambient temperature.

MIDDLE

Summary of Contents for UC-1901BK

Page 1: ...Distributor Contacts UC 1801 KO2 10F KO2 2F UC 1901 Professional Multifunctional Veterinary Intensive Care Unit WMS 1501 Professional Vet Equipments Supplier User Manual...

Page 2: ...dimensions General usage guidelines General opreation tips Radio requency interferece Choosing the working space for the unit Parameters Operation guidance Setting interface Setting mode Trouble shoo...

Page 3: ...ge caused by a third party Transport or Delivery Company The day the unit is delivered an inspection of the outer packing should be made for any damage to the packing box Then the unit should be unpac...

Page 4: ...dB A Control Panel Screen Type Max Power Consumption Average Power Consumption Power Supply Failure Protection Negative Ion Generator Accessories Built in Printer Ultra violet Sterilization Blue Light...

Page 5: ...and displays 1 Setting Mode Allows the operator to switch on off and set all the changeable running parameters for most functions 2 Operating History Allowing the operator to view a complete operatio...

Page 6: ...rbon dioxide figure in CO2 Density bar c Input the desired carbon dioxide density by clicking the newly displayed setting box within the range of 200 2000ppm d Click Enter to set the new carbon dioxid...

Page 7: ...ight Therapy Exam Light Emergency Vent Se ng Blue Light Therapy MIDDLE 12 Nebulizer and Timer a Open the nebulizer chamber door on front control panel of the machine b Gently take the nebulizer assemb...

Page 8: ...er reminder In box 4 it shows the elapsed working time from last replacement box 2 is for resetting the validation time for different suppliers soda lime If you are using the soda lime from our compan...

Page 9: ...and right compartments will start to operate 1 Temperature Sensor Humidity Sensor Replacement Both Temperature and humidity sensors can be found can be found at the innermost top corner of the compart...

Page 10: ...he top cover on ICU compartment to expose internal components Please find the negative ion generator check if it s broken Open and remove the protective cover on the emergency ventilation fan on the b...

Reviews: