Product Dimensions

General Usage Guidelines

General Operation Tips

Radio Requency Interferece

696mm ( 2 �  3  13/32 inch)

850mm ( 2 �  9  15/32 inch)

790mm ( 2 �   7 7/64 inch)

1509mm ( 4 �  11  25/64 inch)

870mm ( 2 �  10  15/64 inch)

1115.7mm ( 3 �  7  59/64 inch)

1509mm (4�  11  13/32 inch)

1899mm (6 �  2  49/64 inch)

884mm (2 � 10  51/64 inch)

03

Internal dimension of large compartment: 1236×600×695mm (4 ft   21/32 inch × 1 ft   11 5/8 inch × 2 

ft   3 23/64 inch)

Internal dimension of medium compartment: 550×600×485mm (1 ft   9 21/32 inch × 1 ft   11 5/8 inch 

× 1 ft   7 3/32 inch)

The KaniStar UC-1901 Multifunctional Veterinary Intensive Care Unit is For Animal Use Only.

There is no reference in this handbook for human hospitals or home users. 
Normothermia maintenance, fluid transfusion, oxygen supplement, blue light therapy, nebulization 
treatment, emergency rescue, in house observation can all be carried out by this unit.
All normal operations and maintenance of the unit should be done by a qualified trained operator under 
the supervision of a licensed qualified veterinarian.
The manufacturer will not be responsible or liable for the results of any incorrect use. 
The full instruction manual should be read prior to use.
The manufacturer is not liable for any damage caused by a third party "Transport or Delivery Company”. 
The day the unit is delivered, an inspection of the outer packing should be made for any damage to the 
packing box. 
Then the unit should be unpacked carefully; all components, accessories, spare parts and the machine 
itself should be inspected for any damage or loss. 
If any damage is evident, the carrier or dealer should be notified immediately.

The machine needs to be turned on with temperature set, running for 3 -5 minutes prior to actual usage 
of any other functions.
A strict non-smoking policy should be applied. 
The unit should Not be used as a table or have anything placed on it at anytime. 
The air filtration system should be checked and cleaned regularly; an unclean filtration system can 
cause an increase of carbon dioxide in the compartment. 
The self-diagnostic system and repair guide can be used for any malfunctions of the machine. 
We recommend disconnecting the power supply to this unit at the mains supply if it will not be in use 
for extended periods.
Please only use a mild household cleaner or “Aseptic Plus” clinical grade disinfectant and a non-abra-
sive cloth or sponge when needed, for cleaning the transparent doors.

Radio Frequency Interference (RFI) influences most electronic equipment. 

CAUTION

 should be 

exercised with regard to the use of portable communication equipment in the area around such 

equipment.

 

25.0

OFF

30.0

0

Summary of Contents for UC-1901BK

Page 1: ...Distributor Contacts UC 1801 KO2 10F KO2 2F UC 1901 Professional Multifunctional Veterinary Intensive Care Unit WMS 1501 Professional Vet Equipments Supplier User Manual...

Page 2: ...dimensions General usage guidelines General opreation tips Radio requency interferece Choosing the working space for the unit Parameters Operation guidance Setting interface Setting mode Trouble shoo...

Page 3: ...ge caused by a third party Transport or Delivery Company The day the unit is delivered an inspection of the outer packing should be made for any damage to the packing box Then the unit should be unpac...

Page 4: ...dB A Control Panel Screen Type Max Power Consumption Average Power Consumption Power Supply Failure Protection Negative Ion Generator Accessories Built in Printer Ultra violet Sterilization Blue Light...

Page 5: ...and displays 1 Setting Mode Allows the operator to switch on off and set all the changeable running parameters for most functions 2 Operating History Allowing the operator to view a complete operatio...

Page 6: ...rbon dioxide figure in CO2 Density bar c Input the desired carbon dioxide density by clicking the newly displayed setting box within the range of 200 2000ppm d Click Enter to set the new carbon dioxid...

Page 7: ...ight Therapy Exam Light Emergency Vent Se ng Blue Light Therapy MIDDLE 12 Nebulizer and Timer a Open the nebulizer chamber door on front control panel of the machine b Gently take the nebulizer assemb...

Page 8: ...er reminder In box 4 it shows the elapsed working time from last replacement box 2 is for resetting the validation time for different suppliers soda lime If you are using the soda lime from our compan...

Page 9: ...and right compartments will start to operate 1 Temperature Sensor Humidity Sensor Replacement Both Temperature and humidity sensors can be found can be found at the innermost top corner of the compart...

Page 10: ...he top cover on ICU compartment to expose internal components Please find the negative ion generator check if it s broken Open and remove the protective cover on the emergency ventilation fan on the b...

Reviews: