Clamp-on Multimeter Model F03
17
MIN/MAX Mode:
Accuracy: same as previous table +0.2% of Reading
Capture Time: 100 ms typical (every 800ms)
3.2.7 Power Supply
Battery:
Standard 9V alkaline (type IEC 6LF22, 6LR61 or NEDA 1604)
Charge life:
75 h or 25,000 x 10 s measurements
Low Battery indicator:
Flashing:
Charge life < 1 h
Fixed:
Change battery
Auto-off:
10 minutes with no action on the rotary switch or the buttons
3.3
Mechanical Specifications
Temperature:
0
10
20
30
40
50
60
70
80
90
-50
-40
-30
-10
10
80
70
60
50
40
30
20
-20
90
➂
➂
➁
➀
0
Temperature in °C
Relative humidity in % RH
Operating Temperature:
32 to 122°F (0 to 50°C); 90% RH
Storage Temperature:
-40 to 158°F (-40 to 70°C); 90% RH
Altitude:
Operation: ≤2000m
Storage: ≤12,000m
Dimensions:
2.76 x 7.6 x 1.46" (70 x 193 x 37mm)
Weight:
9.17 oz (260g)
Clamp Tightening Capacity:
≤1.00” (≤26mm)
1. Reference Range
2. Operating Range
3. Storage Range (without battery)
Summary of Contents for F03