Infrared K-Thermometer Model CA876

 

5

 

2.2 

Button Functions

2.2.1  Center (Yellow) Button - MEAS

Press this button to turn the thermometer ON and perform a measure-

ment.  When  the  button  is  released,  the  meter  will  automatically  HOLD 

(freeze) the last reading on the display for approximately 15 to 20 seconds 

before automatically shuting OFF.

2.2.2  Mode Button

Pressing this button makes the thermometer enter and advance though 

several functions including some programmable functions. The MODE 

button is used to select a specific function (e.g. MIN, MAX) or to adjust an 

Alarm or the emissivity.

To enter the mode program, press 

MODE

 once. SET is displayed in lower 

right hand corner.

When pressed consecutively, it will scroll through the following settings:

ε

 

 

ε

 (Set) 

 ALM Hi (Set) 

 ALM Lo (Set) 

 MAX 

 MIN

 K

 

ε

 

SET is displayed in the lower right hand corner of the display when a 
selected function is programmable (

ε

, ALM Hi, ALM Lo).

ε

Emissivity may be adjusted with the 

 and 

 buttons to match a particu-

lar target. We recommend leaving it at 0.95 for general use.

ALM Hi:

 The Hi alarm set point is adjusted using the 

 and 

 buttons. When 

this set point is reached the beeper will sound and ALM HI will be displayed.

ALM Lo: 

The Lo alarm set point is adjusted using the 

 and 

 buttons. 

When this set point is reached the beeper will sound and ALM Lo will be 

displayed.

MAX:

 The Max value measured will be displayed during measurement. While 

in the MAX mode and when measuring, the MODE button will toggle the mea

-

surement between MAX – MIN – Present reading – MAX.

MIN:

 The Min value measured will be displayed during measurement. While 

in the MIN mode and when measuring, the MODE button will toggle the mea

-

surement between MIN – Present reading – MAX – MIN.

K: 

The lower display will indicate the reading from the K-type thermocouple.

NOTE:

 If the thermometer is OFF, pressing the “MEAS” button for more than 

4 seconds will set the thermometer in the MIN/MAX record mode when pow

-

ered up.

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for CA876

Page 1: ...INFRARED K THERMOMETER WITH LASER CA876 E N G L I S H User Manual Auto OFF www com information itm com 1 800 561 8187...

Page 2: ...e record this number and purchase date for your records INFRARED K THERMOMETER MODEL CA876 CATALOG 2121 34 SERIAL ________________________________________________ PURCHASE DATE _______________________...

Page 3: ...pecifications 7 3 1 1 Infrared 7 3 1 2 K Type 8 3 2 General Specifications 9 3 3 Safety Specifications 9 4 OPERATION 10 4 1 Infrared Measurement Considerations 10 4 2 Recommendations before Operating...

Page 4: ...se the thermom eter to strong electrical or electromagnetic fields To prevent sensor damage and erroneous readings do not put the sensor lens into contact with any body or foreign loose material when...

Page 5: ...Output 0 5mW 670nm wavelength 1 2 Receiving Your Shipment Upon receiving your shipment make sure that the contents are consistent with the packing list Notify your distributor of any missing items If...

Page 6: ...mode non contact temperature mea surement An aiming laser enables the user to pinpoint the target The K type thermocouple input may also be used The thermometer includes a programmable Alarm which tri...

Page 7: ...ble ALM Hi ALM Lo Emissivity may be adjusted with the and buttons to match a particu lar target We recommend leaving it at 0 95 for general use ALM Hi The Hi alarm set point is adjusted using the and...

Page 8: ...or OFF The symbol is displayed in the upper left hand corner when the laser is ON Remove the laser cover before use The laser is activated when the MEAS button is pressed during a mea surement In the...

Page 9: ...6 F 3 C whichever is greater 64 4 to 82 4 F 18 to 28 C ambient operating temperature Temperature Coefficient Changes in accuracy operating temperature above 82 4 F 28 C or below 64 4 F 18 C 0 2 of Rea...

Page 10: ...328 F to 1999 F 0 1 of Reading 2 F plus T C 199 C to 1370 C 0 1 of Reading 1 C plus T C Accuracy is specified for operating temperatures over the range of 64 to 82 F 18 to 28 C for 1 year excluding th...

Page 11: ...o Power Off 15 seconds approx Altitude 2000m max Input Protection 24VDC or 24rms maximum input voltage on any combi nation of inputs Battery Standard 9V battery NEDA 1604 6LR61 or equivalent Battery L...

Page 12: ...lter The output signal from the infrared radiation sensor is input to an electronic circuit along with the output signal from a standard temperature sensor to calculate the temperature and display it...

Page 13: ...e 0 78 Mortar 0 89 to 0 91 Iron oxide 0 78 to 0 82 Brick red 0 93 to 0 96 Textiles 0 90 4 2 Recommendations before Operating If the measured surface target diameter is less than 2 50mm then place the...

Page 14: ...n is released the measurement will be held in the display for 15 20 seconds HOLD is displayed in the lower left hand corner of the display 8 The IR thermometer will shut OFF automatically after 15 20...

Page 15: ...down the button then press the MEAS button F will be displayed The selected temperature scale will remain until changed by the user 4 6 Continuous Measurement The user may want to leave the thermomet...

Page 16: ...lacement is needed Replace with a standard 9 volt alkaline battery NEDA 1604 6LR61 To replace the battery Turn the meter OFF Remove the rubber holster Remove the screw from the back of the meter and l...

Page 17: ...rtificate plus recorded calibration data Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax 603 742 2346 or 603 7...

Page 18: ...nt to us for repair provided we have your warranty registration information on file or a proof of purchase AEMC Instruments will at its option repair or replace the faulty material REGISTER ONLINE AT...

Page 19: ...Notes www com information itm com 1 800 561 8187...

Page 20: ...03 12 99 MAN 100246 v5 Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 603 749 6434 Fax 603 742 2346 www aemc com www com information itm com 1 800 561 8187...

Reviews: