background image

Model

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

Rich Black - 

20/20/20/100

Blue -  100/80/30/5

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0

Blue -  100/80/30/5

Only if you REALLY need them:

Pantone 534 Blue -  100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

Instruction Manual

Infrared Thermometer

R2001

reedinstruments

www

com

Warning

Do not point laser directly or indirectly (through reflective surfaces) at eye.

Features

•  Safely measure surface temperatures of hot, hazardous or 
  hard-to-reach objects without contact
•  User selectable °F or °C
•  Built-in laser pointer identifies target area
•  8:1 Distance to Spot Size ratio
•  Fixed emissivity covers 90% of all applications
•  Automatic Data hold
•  Display backlight
•  Low battery indication with auto shut off
•  Includes battery

Specifications

 

Temperature Range: 

-58 to 536°F (-50 to 280°C)

Accuracy:  

 

±2% or ±2°C

Resolution: 

 

1°F or (°C)

Response Time: 

 

≤ 0.8s

Emissivity: 

 

0.95 Fixed

Optical Resolution:   

8:1

Spectral Response:  

5 to 14μm

Power Supply: 

 

9V (included)

Dimensions: 

 

3.7 x 2.1 x 1” (94 x 56 x 28mm)

Weight:   

 

2.7 oz (76g)

Instruments Description

 

 

 

 

 

 

 

 

 

 

1. LCD Display   

 

5. Laser

2. Back Light Button 

 

6. Infrared Lens

3. Laser Button   

 

7. Measuring Trigger

4. °C / °F Button  

 

8. Battery Cover

Display Description

1. Laser Signal
2. Data Hold Icon
3. Low Battery Symbol
4. 

°C / °F Symbol

5. Current Temperature

Optical Resolution Information:

1.  When taking measurements, point thermometer toward the de-

sired object and hold the trigger. The object should be larger than 
the spot size.

2.  Optical Resolution: As the distance from the object increases, the 

measuring spot size area becomes larger.

3.  Field of view: Make sure the target is larger than the unit’s spot 

size. The smaller the target the closer you must be. When accuracy 
is critical, make sure the target is at least twice as large as the spot 
size.

4.  Emissivity: Most organic materials, painted or oxidized surfaces 

have an emissivity of 0.95 (pre-set in the unit). Inaccurate readings 
will result from measuring shiny or polished metal surfaces. To 
compensate, cover the surface to be measured with masking tape 
or black paint. Measure the covered surface when it reaches the 
same temperature as the material underneath.

Introduction

Compact, rugged and easy to use. Just aim and push the button, it reads 
current surface temperatures in less than a second press the trigger to 
display reading & battery icon. Release the trigger and the reading will 
hold for 15 seconds. 

How it works

The Infrared thermometer measures the surface temperature of an object. 
The unit’s optical sensor emits, reflects, and transmits energy which is 
collected and focused onto a detector. The unit’s electronics translate the 
information into a temperature reading which is displayed on the unit. 

Cautions

Infrared thermometers should be protected from the following:
1.  EMF (electro-magnetic fields) from arc welders, induction heaters.
2.  Thermal shock (caused by large or abrupt ambient temperature 

changes, it allows 30 minutes for unit to stabilize before use).

3.  Do not leave the unit on or near objects of high temperature.

Maintenance

1.  Lens cleaning: Use compressed air to blow off loose particles, use 

a soft brush to remove debris away, and clean it with damp cotton 
cloth.

2.  Case cleaning: Clean the case with a damp sponge/cloth and mild 

soap. 

3.  Do not use solvent to clean lens.
4.  Do not submerge the unit in water.

Battery Replacement

1.  Pull battery cover away from unit
2.  Replace with battery respecting the polarity 9v.

For service on this or any other REED product or information on other REED products, 
contact REED Instruments at [email protected]

Reviews: