Infrared K-Thermometer Model CA876

 

15

 

Repair and Calibration

To ensure that your instrument meets factory specifications, we recommend 

that it be scheduled back to our factory Service Center at one-year intervals 

for recalibration, or as required by other standards or internal procedures.

For instrument repair and calibration:

You must contact our Service Center for a Customer Service Authorization 

Number (CSA#). This will ensure that when your instrument arrives, it will be 

tracked and processed promptly. Please write the CSA# on the outside of the 

shipping  container.  If  the  instrument  is  returned  for  calibration,  we  need  to 

know if you want a standard calibration, or a calibration traceable to N.I.S.T. 

(Includes calibration certificate plus recorded calibration data). 

Ship To:

  Chauvin Arnoux

®

, Inc. d.b.a. AEMC

®

 Instruments

 

15 Faraday Drive

 

Dover, NH 03820 USA

 

Phone: (800) 945-2362  (Ext. 360)

 

 

(603) 749-6434  (Ext. 360)

 

Fax:  (603) 742-2346 or (603) 749-6309

 

E-mail: [email protected]

(Or contact your authorized distributor)
Costs for repair, standard calibration, and calibration traceable to N.I.S.T. are 

available.

NOTE: You must obtain a CSA# before returning any instrument.

Technical and Sales Assistance

If you are experiencing any technical problems, or require any assistance with 

the proper operation or application of your instrument, please call, mail, fax or 

e-mail our technical support team:

 

Chauvin Arnoux

®

, Inc. d.b.a. AEMC

®

 Instruments

 

200 Foxborough Boulevard

 

Foxborough, MA 02035 USA

 

Phone: (800) 343-1391

 

 

(508) 698-2115

 

Fax:  (508) 698-2118

 

E-mail: [email protected] 

 www.aemc.com

NOTE: Do not ship Instruments to our Foxborough, MA address.

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for CA876

Page 1: ...INFRARED K THERMOMETER WITH LASER CA876 E N G L I S H User Manual Auto OFF www com information itm com 1 800 561 8187...

Page 2: ...e record this number and purchase date for your records INFRARED K THERMOMETER MODEL CA876 CATALOG 2121 34 SERIAL ________________________________________________ PURCHASE DATE _______________________...

Page 3: ...pecifications 7 3 1 1 Infrared 7 3 1 2 K Type 8 3 2 General Specifications 9 3 3 Safety Specifications 9 4 OPERATION 10 4 1 Infrared Measurement Considerations 10 4 2 Recommendations before Operating...

Page 4: ...se the thermom eter to strong electrical or electromagnetic fields To prevent sensor damage and erroneous readings do not put the sensor lens into contact with any body or foreign loose material when...

Page 5: ...Output 0 5mW 670nm wavelength 1 2 Receiving Your Shipment Upon receiving your shipment make sure that the contents are consistent with the packing list Notify your distributor of any missing items If...

Page 6: ...mode non contact temperature mea surement An aiming laser enables the user to pinpoint the target The K type thermocouple input may also be used The thermometer includes a programmable Alarm which tri...

Page 7: ...ble ALM Hi ALM Lo Emissivity may be adjusted with the and buttons to match a particu lar target We recommend leaving it at 0 95 for general use ALM Hi The Hi alarm set point is adjusted using the and...

Page 8: ...or OFF The symbol is displayed in the upper left hand corner when the laser is ON Remove the laser cover before use The laser is activated when the MEAS button is pressed during a mea surement In the...

Page 9: ...6 F 3 C whichever is greater 64 4 to 82 4 F 18 to 28 C ambient operating temperature Temperature Coefficient Changes in accuracy operating temperature above 82 4 F 28 C or below 64 4 F 18 C 0 2 of Rea...

Page 10: ...328 F to 1999 F 0 1 of Reading 2 F plus T C 199 C to 1370 C 0 1 of Reading 1 C plus T C Accuracy is specified for operating temperatures over the range of 64 to 82 F 18 to 28 C for 1 year excluding th...

Page 11: ...o Power Off 15 seconds approx Altitude 2000m max Input Protection 24VDC or 24rms maximum input voltage on any combi nation of inputs Battery Standard 9V battery NEDA 1604 6LR61 or equivalent Battery L...

Page 12: ...lter The output signal from the infrared radiation sensor is input to an electronic circuit along with the output signal from a standard temperature sensor to calculate the temperature and display it...

Page 13: ...e 0 78 Mortar 0 89 to 0 91 Iron oxide 0 78 to 0 82 Brick red 0 93 to 0 96 Textiles 0 90 4 2 Recommendations before Operating If the measured surface target diameter is less than 2 50mm then place the...

Page 14: ...n is released the measurement will be held in the display for 15 20 seconds HOLD is displayed in the lower left hand corner of the display 8 The IR thermometer will shut OFF automatically after 15 20...

Page 15: ...down the button then press the MEAS button F will be displayed The selected temperature scale will remain until changed by the user 4 6 Continuous Measurement The user may want to leave the thermomet...

Page 16: ...lacement is needed Replace with a standard 9 volt alkaline battery NEDA 1604 6LR61 To replace the battery Turn the meter OFF Remove the rubber holster Remove the screw from the back of the meter and l...

Page 17: ...rtificate plus recorded calibration data Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax 603 742 2346 or 603 7...

Page 18: ...nt to us for repair provided we have your warranty registration information on file or a proof of purchase AEMC Instruments will at its option repair or replace the faulty material REGISTER ONLINE AT...

Page 19: ...Notes www com information itm com 1 800 561 8187...

Page 20: ...03 12 99 MAN 100246 v5 Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 603 749 6434 Fax 603 742 2346 www aemc com www com information itm com 1 800 561 8187...

Reviews: