7
Automatic range selection : read the measured value
Freeze the value, by pressing the HOLD button.
If necessary, press the following buttons:
RANGE to select the range manually
MIN-MAX to read the min or max values
to light the display
5-1
Resistances
Ω
Ω
Ω
Ω
Ω
400
Ω
4 k
Ω
40 k
Ω
400 k
Ω
4 M
Ω
40 M
Ω
Digital
resolution
0.1
Ω
1
Ω
10
Ω
100
Ω
1 k
Ω
10 k
Ω
Bargraph
10
Ω
100
Ω
1 k
Ω
10 k
Ω
100 k
Ω
1 M
Ω
resolution
Accuracy
± 1.5% R
± 1.5% R ±3cts
± 3% R
± 8 cts
± 5 cts
Voltage on
open circuit
≤
0.5V DC
Protection
500V rms and 750V peak
5-2
Continuity sound test
On the 400
Ω
range, continuous beep for a resistance R
≤
40
Ω
.
6 - DIODE TEST
Never test a diode on a live circuit
Connect the leads to the multimeter and to the terminals of the
component to be tested.
Place the selector switch on the diode function
:
- in forward direction the display gives the value of the junction in
volts (resolution 1mV)
- accuracy : ± 2% of Reading ±15mV
- open circuit voltage :
≥
3V
- short circuit current : 0.8mA
- in reverse direction the display indicates the open circuit voltage,
around 3V.
Freeze the value, by pressing the HOLD button.
With this function it is thus possible to test standard diodes, led’s
or any other semiconductor which has a junction that corresponds
to a direct voltage of less than 3V.