Warning !

  Please refer to the User’s Manual before using

the instrument.
In this User’s Manual, the instructions preceded by the above
symbol, should they not be carried out as shown, can result in a
physical accident or damage the instrument and the installations.

This device is protected by a double insulation or by a reinforced
insulation. No linking is required from the protection earth terminal
to ensure the electrical security.

Thank you for purchasing a 

C.A 5210 

or

 C.A 5220 Multimeter

.

To get the best service from this instrument :

 

 read

 this user manual carefully,

   

respect

 the safety precautions detailed.

  SAFETY PRECAUTIONS 

Respect the value and the type of fuses or there is risk of
deterioration of the instrument and invalidation of the warranty.
- Fuse 0.4 A HBC - 600 V min (6.3 x 32 mm)
- Fuse 12 A HBC - 600 V min (10.3 x 38 mm)
Never use on voltage to earth circuits above 600 V, with a voltage
surge category of over III, that is to say, fixed industrial and
domestic installations (ref. IEC 664-1).
To be used indoors in environments with a maximum pollution
degree of 2 (ref. IEC 664-1), a temperature between 0 and 50°C
and relative humidity below 70%.

 

 

Use accessories which conform to safety standards

(IEC 1010-2-031), with a minimum voltage of 600 V and a voltage
surge of category III.
Never open the multimeter case before disconnecting from any
electrical source.
Never connect up to a circuit to be measured if the multimeter
case is not closed correctly.
Before any measurements are taken, ensure the leads and switch
are in the correct positions.
Never measure resistances on a circuit with the power switched
on.
For the C.A 5220 multimeter, when making current measurements,
always switch Off the power supply to the circuit before
connecting or disconnecting the instrument to the circuit.

Summary of Contents for C.A 5210

Page 1: ...italMultimeters Model C A 5210 Model C A 5220 MULTIMETER Hz Velec V OFF mA 10 A M I N MAX RANGE HOLD 10A 400mA FUSED 10 A max FUSED C A 5220 COM 600V CAT III M U L T I M E T E R MAX RANGE n F Hz mVA M...

Page 2: ...Fuse 12 A HBC 600 V min 10 3 x 38 mm Never use on voltage to earth circuits above 600 V with a voltage surge category of over III that is to say fixed industrial and domestic installations ref IEC 664...

Page 3: ...00 counts 40 segment bargraph The range selection is automatic with the possibility of manual selection on the C A 5220 It switches Off automatically if no control or function button is pressed for 30...

Page 4: ...Automatic selection of AC and when it is switched on HOLD To freeze the last measurement digital and bargraph MIN MAX C A 5220 only To successively display the min or max values The C A 5220 then cha...

Page 5: ...DC current ranges via the 10A terminal mA C A 5220 only Current ranges up to 400mAAC DC via the terminal TERMINALS 4mm safety terminals COM common black red 10A C A 5220 only red lead for the 10AAC D...

Page 6: ...mV 1mV 10mV 100mV 1V resolution Bargraph 10mV 100mV 1V 10V 100V resolution V AC Impedance 10M V elec Impedance 270k Accuracy 3 5 R 1 5 of Reading 1ct Permitted 600V rms and 900V peak overload 1 C A 52...

Page 7: ...the 400 range continuous beep for a resistance R 40 6 DIODE TEST Never test a diode on a live circuit Connect the leads to the multimeter and to the terminals of the component to be tested Place the s...

Page 8: ...F 400nF 4 F 40 F Resolution 1pF 10pF 100pF 1nF 10nF Accuracy 3 R 3 R 5 R 15 R 400cts 25cts 10cts 10cts Protection 500V rms and 750V peak 1 Min measurement 400 pF 8 FREQUENCY C A 5220 only Connect the...

Page 9: ...in or max values to light the display DC currents A DC 40mA 400mA 10A 1 Voltage 600mV 4 5V 600mV drop 2 Digital 10 A 100 A 10mA resolution Bargraph 1mA 10mA 1A resolution Accuracy 1 5 of Reading 1ct 1...

Page 10: ...are pressed and for the overload indication Note No beep on button and on switch between V and Velec 10 4 Climatic conditions Temperature use 0 C to 50 C storage 20 C to 60 C Relative humidity use 80...

Page 11: ...10 12A for C A 5220 Cat 2970 21 12 WARRANTY Our guarantee is applicable for three years after the date on which the equipment is made available copy available on request 13 MAINTENANCE For maintenanc...

Page 12: ...tandards For instrument repair and or calibration please call our factory toll free at 800 945 AEMC 800 945 2362 CHAUVINARNOUX Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Tel 800 95...

Reviews: