background image

11

11 - TO ORDER

C.A 5210

.....................................................................

Cat #2116.74

C.A 5220

.....................................................................

Cat #2116.75

Supplied with a shockproof case, pair of leads with probes attached,
two 1.5V "AA" batteries and this user manual

Accessories

AC Current Probe Model MN251 (200A

AC

) ..............

Cat #2115.77

AC Current Probe Model MD303 (500A

AC

) ..............

Cat #1201.21

AC Current Probe Model SR652 (1000A

AC

) ............

Cat #2113.46

AC/DC MicroProbe Model K110

(from 100µA

AC/DC

 to 300mA

AC

/ 450mA

DC

) .................

Cat #2111.73

AC/DC Current Probe model MR410

(400A

AC

/600A

DC

) ........................................................

Cat #1200.70

AmpFlex

 Model 1000-24-1-1 (1000A

AC

) ...............

Cat #2112.39

Replacement leads ...................................................

Cat #2118.66

Soft carrying case ...................................................

Cat #2118.65

Replacement shockproof case ................................

Cat #2980.15

Fuse set of 10, 0.4A for C.A 5220 ...........................

Cat #2970.20

Fuse set of 10, 12A for C.A 5220 ............................

Cat #2970.21

12 -  WARRANTY

Our guarantee is applicable for 

three years

 after the date on which

the equipment is made available (copy available on request).

13 - MAINTENANCE

For maintenance, use only specified spare parts.
The manufacturer will not be held responsible for any
accident occurring following a repair done other than
by its After Sales Service or approved repairers.

13-1 Replacing the batteries and the fuses

  The multimeter must be disconnected from any electrical source.

The 1.5V batteries, as well as the 0.4A HPC and 12A HPC fuses for
model C.A 5220, are accessible at the back of the instrument.
Remove the lower half of the case after removing the three screws.
Replace the faulty elements, in accordance with :

polarity for the batteries
the value and the type of fuses
Fuse 0.4A HBC - 600V min (6.3 x 32mm)
Fuse 12A HBC  - 600V min (10.3 x 38mm)

Summary of Contents for C.A 5210

Page 1: ...italMultimeters Model C A 5210 Model C A 5220 MULTIMETER Hz Velec V OFF mA 10 A M I N MAX RANGE HOLD 10A 400mA FUSED 10 A max FUSED C A 5220 COM 600V CAT III M U L T I M E T E R MAX RANGE n F Hz mVA M...

Page 2: ...Fuse 12 A HBC 600 V min 10 3 x 38 mm Never use on voltage to earth circuits above 600 V with a voltage surge category of over III that is to say fixed industrial and domestic installations ref IEC 664...

Page 3: ...00 counts 40 segment bargraph The range selection is automatic with the possibility of manual selection on the C A 5220 It switches Off automatically if no control or function button is pressed for 30...

Page 4: ...Automatic selection of AC and when it is switched on HOLD To freeze the last measurement digital and bargraph MIN MAX C A 5220 only To successively display the min or max values The C A 5220 then cha...

Page 5: ...DC current ranges via the 10A terminal mA C A 5220 only Current ranges up to 400mAAC DC via the terminal TERMINALS 4mm safety terminals COM common black red 10A C A 5220 only red lead for the 10AAC D...

Page 6: ...mV 1mV 10mV 100mV 1V resolution Bargraph 10mV 100mV 1V 10V 100V resolution V AC Impedance 10M V elec Impedance 270k Accuracy 3 5 R 1 5 of Reading 1ct Permitted 600V rms and 900V peak overload 1 C A 52...

Page 7: ...the 400 range continuous beep for a resistance R 40 6 DIODE TEST Never test a diode on a live circuit Connect the leads to the multimeter and to the terminals of the component to be tested Place the s...

Page 8: ...F 400nF 4 F 40 F Resolution 1pF 10pF 100pF 1nF 10nF Accuracy 3 R 3 R 5 R 15 R 400cts 25cts 10cts 10cts Protection 500V rms and 750V peak 1 Min measurement 400 pF 8 FREQUENCY C A 5220 only Connect the...

Page 9: ...in or max values to light the display DC currents A DC 40mA 400mA 10A 1 Voltage 600mV 4 5V 600mV drop 2 Digital 10 A 100 A 10mA resolution Bargraph 1mA 10mA 1A resolution Accuracy 1 5 of Reading 1ct 1...

Page 10: ...are pressed and for the overload indication Note No beep on button and on switch between V and Velec 10 4 Climatic conditions Temperature use 0 C to 50 C storage 20 C to 60 C Relative humidity use 80...

Page 11: ...10 12A for C A 5220 Cat 2970 21 12 WARRANTY Our guarantee is applicable for three years after the date on which the equipment is made available copy available on request 13 MAINTENANCE For maintenanc...

Page 12: ...tandards For instrument repair and or calibration please call our factory toll free at 800 945 AEMC 800 945 2362 CHAUVINARNOUX Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Tel 800 95...

Reviews: