Current Probes & Sensors for Power Quality Meters

 

4. SPECIFICATIONS

4.1  Electrical

NOTE: 

The  measurement  ranges  specified  are  for  the  probes  and  sensors. 

In  some  cases,  they  may  differ  from  the  ranges  that  can  be  measured  by  the 

instrument with which they are used with.

 

For complete specifications:

 Refer to the product user manual that is supplied 

with each compatible instrument.

Model

Measurement Range

Compatibility

AmpFlex

®

 193-24-BK 

(1)

 

24

"

 (610mm)

200mA to 10kA

AC

 

(2)

 

(12,000A)

 

(3)

8333, 8336 & PEL Series

AmpFlex

®

 193-36-BK 

(1)

 

36

"

 (910mm)

200mA to 10kA

AC

 

(2)

 

(12,000A)

 

(3)

8333, 8336 & PEL Series

AmpFlex

®

 A196-24-BK 

(1)

 

24

"

 (610mm)

200mA to 10kA

AC

 

(2)

 

(12,000A)

 

(3)

8435

MiniFlex

®

 MA193 

(1)

 

10

"

 (250 mm)

200mA to 3000A

 

(10,000A peak)

 

8333, 8336 & PEL Series

MiniFlex

®

 MA193 

(1)

 

14

"

 (355 mm)

200mA to 3000A

 

(10,000A peak)

 

8333, 8336 & PEL Series

J93 

50 to 3500; 

50 to 5000 (DC only)

8333, 8336, 8435 and PEL

MN93

2 to 240A

AC

 

(I >200A not permanent)

All PowerPads and PEL

MN193

5A: 0.005 to 6A

AC

100A: 0.1 to 120A

AC

All PowerPads and PEL

MR193

10 to 1000A

AC

10 to 1300A

PEAK AC+DC

All PowerPads and PEL

SL261

100mV/A: 100mA to 10A peak

10mV/A: 1 to 100A peak

8333, 8336, 8435 and PEL

SR193

1 to 1200A

AC 

 

(I > 1000A not continuously)

All PowerPads and PEL

(1) 10 to 6500A

AC

 for Model 8435

(2) 200mA to 10,000A measurement range for the PEL 100 Series.

(3) 12,000A is specified for the PEL 100 Series only.

 

Battery: 9V Alkaline NEDA 1604A, 6LR61
Battery Life:  MR193 - 100H typical

 

SL261 - 55H typical

 

J93 - 70H typical

NOTE: 

Battery life is twice the typical value when using Lithium batteries

www.calcert.com

[email protected]

1.888.610.7664

0

5

10

15

20

25

30

Summary of Contents for 193-24-BK

Page 1: ...ES SENSORS FOR POWER QUALITY METERS 193 24 BK 193 36 BK A196 24 BK MA193 10 BK MA193 14 BK J93 MN93 BK MN193 BK MR193 BK SL261 BK SR193 BK E N G L I S H User Manual www calcert com sales calcert 8 610...

Page 2: ...express implied or otherwise Chauvin Arnoux Inc has made every reasonable effort to ensure that this documentation is accurate but does not warrant the accuracy or completeness of the text graphics o...

Page 3: ...fully understand Useful information or tip to read The CE marking guarantees conformity with European directives and with regulations covering EMC The trash can with a line through it means that in t...

Page 4: ...ude degree of pollution location Do not use the current probe if its housing is open deteriorated or incorrectly reassembled Before each use check the integrity of the insulation of the unit jaws clam...

Page 5: ...7 2 1 4 AC Current Probe Models MN93 BK MN193 BK 8 2 1 5 AC Current Probe Model MR193 BK 9 2 1 6 AC Current Probe Model SL261 10 2 1 7 AC Current Probe Model SR193 BK 11 3 OPERATION 12 4 SPECIFICATIO...

Page 6: ...probes in this manual are compatible only with AEMC Power Analyzers see 4 for meter compatibility AmpFlex Sensor 24 Model 193 24 BK Cat 2140 34 AmpFlex Sensor 36 Model 193 36 BK Cat 2140 35 AmpFlex Se...

Page 7: ...2 PRODUCT FEATURES 2 1 Control Features 2 1 1 AmpFlex Models 193 24 BK 193 36 BK 196 24 BK 2 3 4 1 1 Flexible sensor 2 Sensor opening connector 3 Shielded lead 4 Custom 4 pin input connector www calce...

Page 8: ...ensors for Power Quality Meters 2 1 2 MiniFlex Model MA193 BK 2 3 4 1 1 Flexible sensor 2 Sensor opening device 3 Shielded lead 4 Custom 4 pin input connector www calcert com sales calcert 8 610 7664...

Page 9: ...4 5 6 3 5000A 500A ZERO Stop Test MARCHE SORTIE ZERO ON OFF 300VCA TIV 600VCA TIII 1 Jaws 2 4 point CA connector 3 Safety guard 4 Zero adjustment knob 5 Power ON Low battery indicator 6 Three positio...

Page 10: ...t Probe Models MN93 BK MN193 BK 200V CAT IV 600V CAT III 200A 5 4 2 3 6 1 1 Jaws 2 Protective guard 3 Two position range switch MN193 only 4 Jaw opening lever 5 Shielded lead 6 Custom 4 pin input conn...

Page 11: ...2 1 5 AC Current Probe Model MR193 BK 5 2 4 3 7 6 1 1 Jaws 2 Protective guard 3 Jaw opening lever 4 Two position range switch 5 Shielded lead 6 Zero adjustment 7 Custom 4 pin input connector www calce...

Page 12: ...1 6 AC Current Probe Model SL261 2 3 5 6 4 1 1 Jaws 2 Zero adjust knob 3 Range selection switch 4 Battery compartment screw 5 Battery compartment cover 6 BNC Adapter sold separately Cat 2140 40 www ca...

Page 13: ...Power Quality Meters 11 2 1 7 AC Current Probe Model SR193 BK 4 2 3 5 1 1 Jaws 2 Protective guard 3 Jaw opening lever 4 Shielded lead 5 Custom 4 pin input connector www calcert com sales calcert 8 61...

Page 14: ...current input to match the phase identifiers on the measured system IMPORTANT NOTE Always connect the probes or sensors with the indicating arrows pointing toward the load For Example Only instrument...

Page 15: ...sides of the opening connector MiniFlex Press the opening device to open the flexible sensor Clamp the sensor around the conductor to be tested For best results center the conductor in the jaws of the...

Page 16: ...10 000A peak 8333 8336 PEL Series MiniFlex MA193 1 14 355 mm 200mA to 3000A 10 000A peak 8333 8336 PEL Series J93 50 to 3500 50 to 5000 DC only 8333 8336 8435 and PEL MN93 2 to 240AAC I 200A not perma...

Page 17: ...x 158 x 25mm 7 7 oz 270g MiniFlex MA193 10 BK 10 250mm 10 ft 3m 2 75 70mm 4 0 x 2 5 x 1 1 103 x 64 x 28mm 1 94 oz 55g MiniFlex MA193 14 BK 14 350mm 10 ft 3m 3 94 100mm 4 0 x 2 5 x 1 1 103 x 64 x 28mm...

Page 18: ...According to IEC 61010 1 Electrical safety according to IEC 61010 2 032 Maximum applicable voltage AmpFlex 1000V CAT III 600V CAT IV MiniFlex 1000V CAT III 600V CAT IV J93 600V CAT III 300V CAT IV MN...

Page 19: ...acement 5 2 1 Model MR193 Disconnect the MR193 completely and turn the rotary switch to OFF Use a screwdriver to unscrew the screws and remove the battery compartment cover on the backside of the unit...

Page 20: ...e it completely by hand Remove the battery and the shim from the compartment Place the new battery in the compartment with the polarity as indicated on the label Then replace the shim Put the battery...

Page 21: ...www calcert com sales calcert 8 610 7664 0 5 10 15 20 25 30...

Page 22: ...repair provided we have your warranty registration information on file or a proof of purchase AEMC Instruments will at its option repair or replace the faulty material 5 6 Warranty Repairs What you m...

Page 23: ...www calcert com sales calcert 8 610 7664 0 5 10 15 20 25 30...

Page 24: ...12 15 99 MAN 100391 v4 Chauvin Arnoux Inc d b a AEMC Instruments www calcert com sales calcert 8 610 7664 0 5 10 15 20 25 30...

Reviews: