27
·
Select the input from the drop down list.
In our example below, we will create a new scaled pressure sensor output that can be used to drive a gauge on the
dash. It will use the Analog 3 input from the 30-2206 on Pin 7. Three things are required. 1.) You must create a
new Output Name. 2.) You must add an Operation to scale the voltage into pressure units. 3.) You must define a
Primary Input. First create the new Output Name. We will use
My Pressure
.
For this example, let's assume that the sensor is a typical 0-5V analog sensor that is calibrated as follows: 0.5 volts
= 0 psi and 4.5 volts = 100 psi. Consult your sensor documentation for proper calibration values. There are several
options but the easiest method is to use a Function table. Lets create a new Function to define this calibration.
In the Functions tab, create a new Function. We will call it My Pressure Sensor Function; Volts to PSI. It will
convert voltage to PSI.
Click on the (...) symbol to define the function table. Enter the data as shown below to create the calibration curve.
Summary of Contents for CD-5 Carbon
Page 12: ...12 Dash Mechanical and Mounting CD 7 Mechanical ...
Page 13: ...13 CD 5 Mechanical ...
Page 14: ...14 CD 7F Mechanical ...
Page 15: ...15 CD 5F Mechanical ...
Page 16: ...16 Drill Template Drill template prints to scale ...
Page 17: ...17 Dash Harness and Basic Wiring ...
Page 18: ...18 Optional OBDII and Power Cable Kits ...
Page 31: ...31 System Schematic ...
Page 39: ...39 IMAGE NOT TO SCALE ...
Page 41: ...41 System Schematic ...
Page 51: ...51 CAN Transmit Rate Unit 1 50 Hz CAN Transmit Rate Unit 2 25 Hz ...
Page 58: ...58 ID Type User Configurable 11 29 bits Termination None Ohm DLC 8 Bytes ...
Page 64: ...64 ...
Page 65: ...65 ...
Page 66: ...66 ...
Page 67: ...67 ...