Aegis EL-RG-49H Operation Manual Download Page 8

23

6

Precautions for Use

Reduce the time of keeping door open when storing or taking articles each time, to prevent great 
fluctuation to the temperature and humidity inside the refrigerator.
The refrigerator will see a sharp temperature increase in a short time when the door is opened, 
which is normal, and the temperature will resume 1h after the door is closed.

The refrigerator shall operate with ambient temperature as 10~32

 and humidity less than 85%; 

condensation will occur on the glass door in high temperature and high humidity condition, which 
is normal and will not affect the storage temperature inside the refrigerator; in the event of 
condensation, please improve ventilation conditions as soon as possible and reduce ambient 
temperature simultaneously.

The temperature display value of refrigerator refers to the temperature value at the temperature 
sensing probe inside the refrigerator. Though the temperature displayed is different from the actual 
one at the center of refrigerator, it will approach to the real temperature gradually.

The refrigerator battery may be low when the refrigerator is restarted after it has been out-of-service 
for a long time; make sure the battery switch is set at “ON” and charge the storage battery, which 
will be full after continuous running of refrigerator for one week.
Make sure the temperature inside the refrigerator has reached the set value and put articles in the 
refrigerator by batch. Volumes accounted by articles shall not be greater than 1/3 of refrigerator to 
prevent rise of temperature.

Clean the refrigerator with neutral detergent diluted. Brushes, acids, gasoline, soap powders, 
polishing powders or hot water are prohibited to clean refrigerator as these materials may damage 
the painting surface and plastic & rubber components and parts. Never wipe the plastic & rubber 
components and parts with volatile solvent such as gasoline.
Shut off the power as well as the battery switch if the refrigerator will be out-of-service for a long 
time.

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection 
facilities.Contact you local government for information regarding the collection systems available.
If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into 
the groundwater and get into the food chain, damaging your health and well-being.When replacing 
old appliances with new ones, the retailer is legally obligated to take back your old appliance for 
disposals at least free of charge.

Meaning of crossed –out wheeled dustbin:

The refrigerator does not work

Fault

Troubleshooting 

Refrigeration effects are not 

apparent, temperature 

exceeds the standard

Noise is too significant

Alarm light flashes, 

the buzzer alarms

Whether the input power meets the requirements

Whether the plug and socket are in loose contact

Whether the input line and control line break down

Whether the voltage is too low

Whether too much or too hot articles are stored

Whether there is certain clearance among stored articles

Whether the refrigerator is exposed to direct sunlight or radiation of other heat sources

Whether the door is opened too often

Whether the ambient temperature is too high

Whether the air duct is blocked

Whether the refrigerator is placed steadily

Whether part of the refrigerator contact external objects or wall

The noise noted in technical data is average data measured in standard laboratory 

without noise when the refrigerator with no stored articles is put on a rubber blanket 

and operates steadily after the door is closed, and data measured during startup & 

shutdown and at 1 m above the surface is not included. It is normal that actual noise 

differs from stated value because of loaded articles, environmental noise, no door 

closing, startup & shutdown of the compressor during using.

Whether the articles are newly put in the refrigerator and the temperature is not 

stabilized at 3~7

. The fault will be eliminated automatically after refrigeration for a 

while.

Whether the door is not closed completely, which triggers alarm of door opening

Whether the power fails, the refrigerator returns to normal condition after starting up 

for a while

Whether the temperature exceeds the standard

FAQ

Do you have questions during using? Do you doubt that the refrigerator breaks 
down? Please read description here. This chapter is to give answers in respect 
of potential fault phenomenon as well as respective solutions.If your question is 
still unresolved after operation, please contact Haier after-sales service.Do not 
maintain and dismantle the refrigerator by yourself!

The maintenance should be supplied by professional after-sales service people once the 
equipment is faulty.

Summary of Contents for EL-RG-49H

Page 1: ...or may vary Translation of the original instruction The scope of the Product Application Pharmaceuticals and other related products which need a storage environment of 2 8 Certi cate of Quality Pharma...

Page 2: ...harmaceutical Refrigerator Type Designation Trademark EL RG 49H Manufactures Name Aegis Scientific Inc Address Tel 1 Ivybrook Blvd Unit 145R Ivyland PA 18974 USA 1 800 796 2344 Fax 732 879 0248 Refer...

Page 3: ...essor and main components and better refrigeration performance User friendly design computer control smart and carefree adjust ment not required High performance thermal insulation layer with excellen...

Page 4: ...the appliance that you have just purchased due to technical improvements 1 Product Feature Content Safety Precautions Precautions for Use Product Installation Component Names Control Panel Applicatio...

Page 5: ...ug in or pull out the power plug of refrigerator to prevent explosion and fire The refrigerator shall be installed by professional technical staffs or after sale maintenance staffs to prevent electric...

Page 6: ...ay pose danger to human health or environment Pull out the power plug if the refrigerator has been out of service for long time to prevent electric shock leakage or fire caused by aging power lines If...

Page 7: ...ust be placed on a solid and flat surface or excessive vibration and noise may be produced when the appliance in operation The appliance can be used by children aged from 8 years and above and persons...

Page 8: ...hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new ones the retailer is legally obligated to tak...

Page 9: ...ion site Do not ground the refrigerator through gas pipes water supply pipes telephone lines or lightning conductors as electric shock may be caused The power plug can be accessed after installation t...

Page 10: ...ownward upward Clean the back evaporating box Evaporating box is installed on the back of the refrigerator Remove 2 screws on the bottom loosen the upper 2 screws no need to remove them lift the evapo...

Page 11: ...m is under normal condition When chargeable battery is closed or with too low a power press once the alarm testing key E6 is expected to flash 3 times on the display window at the simultaneously The r...

Page 12: ...220V 110V failed under any of the above conditions remote alarm shall be started Coupled with 1Hz continuous beeping Take corres ponding measures according to item 1 2 and 3 Remote alarm startup when...

Page 13: ...upper or lower temperature displayed ALH Alarm Limit High settable by the user high temperature alarming is triggered while when any of upper or lower temperature shown ALL Aalrm LImit Low settable by...

Page 14: ...inside temperature display area flashes Date press Minus button or Plus button to adjust the current date and the press Set button to save and confirm Thereafter the inside temperature display area sh...

Page 15: ...e display area steadily shows 2P press Set button the inside temperature display area flashes Month factory default 01 press Minus button or Plus button select Month from 01 12 recycling display after...

Page 16: ...arameter value After setting press Set to go back and choose other parameters for the same token With all values set press Set button 5s exit and return to the normal display mode Temperature Display...

Reviews: