5. Standing

Do not switch on the power after the refrigerator is placed, leveled and cleaned. Switch on the
power after it is put on standing for more than 24h, to ensure normal performance of refrigerator.

6.Installation Rack and Price Card

Take out the rack, price card and rack fastener from the 
refrigerator. Fix the rack fastener on the rack at the 
appropriate distance and height. After mounting the rack 
and price card, place them on the rack fastener and ensure 
the rack is placed flatly and firmly.

It is necessary for the user to install remote alarm device to the remote alarm 
switch by himself

In case of power failure, a fully charged backup battery enables the alarm 
function to keep working for 48 hours. The initial operation requires the 
refrigerator to run at least 2days in a row, while the backup battery needs to be 
charged for the initial operation or after a long time of power failure.
The buzzer beeps 3 times in 1Hz continuous sounds for every press on the 
“Alarm Test ” key, with the alarm indicator flashing 3 times, if under non-remote
hardware alarm conditions, remote alarm relay disconnect after connecting 3s 
alternatively, then alarm action may triggered depending on actual requirements.
This shows the alarm system is under normal condition.
When chargeable battery is closed or with too low a power, press once the alarm
testing key, E6 is expected to flash 3 times on the display window at the 
simultaneously.
The refrigerator shall be charged by special personnel that inspects and records 
its operating conditions every day, if too high or low a temperature is observed, 
the articles in it shall be transferred to others until it is again under normal 
conditions.

In case of an alarm, you can press the key “Silence” on the display panel to stop the alarm. 
(The remote alarm will not be stopped.)

If the alarm condition still exists, the buzzer will make an alarm again automatically 30min. later.

Automatic Alarm Recovery

This series of refrigerators has the automatic alarm recovery function:

Remote alarm terminals are installed on the 
refrigerator and the alarm signal behind the 
compartment is output by the terminals. The 
bearing capacity of the terminals is DC 30V, 2A. 

Terminal output:
Remote alarm terminals include NO, NC and COM. 
The user can choose “NO” or “NC” if needed. 

Remote Alarm Terminals

COM

NO
NC

Fig.4

Fig.5

7. Installation of the Handle

Handle installation of products shall be conducted
in the following steps:

. Orient the handle with the hole downwards

. Align the handle and handle guide on door;

. Uphold the handle after the handle is locked with the

handle guide;

. Use bolt to fix the handle from bottom after tight

installation of the handle.

1

3

2

4

Summary of Contents for EL-RG-49H

Page 1: ...or may vary Translation of the original instruction The scope of the Product Application Pharmaceuticals and other related products which need a storage environment of 2 8 Certi cate of Quality Pharma...

Page 2: ...harmaceutical Refrigerator Type Designation Trademark EL RG 49H Manufactures Name Aegis Scientific Inc Address Tel 1 Ivybrook Blvd Unit 145R Ivyland PA 18974 USA 1 800 796 2344 Fax 732 879 0248 Refer...

Page 3: ...essor and main components and better refrigeration performance User friendly design computer control smart and carefree adjust ment not required High performance thermal insulation layer with excellen...

Page 4: ...the appliance that you have just purchased due to technical improvements 1 Product Feature Content Safety Precautions Precautions for Use Product Installation Component Names Control Panel Applicatio...

Page 5: ...ug in or pull out the power plug of refrigerator to prevent explosion and fire The refrigerator shall be installed by professional technical staffs or after sale maintenance staffs to prevent electric...

Page 6: ...ay pose danger to human health or environment Pull out the power plug if the refrigerator has been out of service for long time to prevent electric shock leakage or fire caused by aging power lines If...

Page 7: ...ust be placed on a solid and flat surface or excessive vibration and noise may be produced when the appliance in operation The appliance can be used by children aged from 8 years and above and persons...

Page 8: ...hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new ones the retailer is legally obligated to tak...

Page 9: ...ion site Do not ground the refrigerator through gas pipes water supply pipes telephone lines or lightning conductors as electric shock may be caused The power plug can be accessed after installation t...

Page 10: ...ownward upward Clean the back evaporating box Evaporating box is installed on the back of the refrigerator Remove 2 screws on the bottom loosen the upper 2 screws no need to remove them lift the evapo...

Page 11: ...m is under normal condition When chargeable battery is closed or with too low a power press once the alarm testing key E6 is expected to flash 3 times on the display window at the simultaneously The r...

Page 12: ...220V 110V failed under any of the above conditions remote alarm shall be started Coupled with 1Hz continuous beeping Take corres ponding measures according to item 1 2 and 3 Remote alarm startup when...

Page 13: ...upper or lower temperature displayed ALH Alarm Limit High settable by the user high temperature alarming is triggered while when any of upper or lower temperature shown ALL Aalrm LImit Low settable by...

Page 14: ...inside temperature display area flashes Date press Minus button or Plus button to adjust the current date and the press Set button to save and confirm Thereafter the inside temperature display area sh...

Page 15: ...e display area steadily shows 2P press Set button the inside temperature display area flashes Month factory default 01 press Minus button or Plus button select Month from 01 12 recycling display after...

Page 16: ...arameter value After setting press Set to go back and choose other parameters for the same token With all values set press Set button 5s exit and return to the normal display mode Temperature Display...

Reviews: