Aegis EL-RG-49H Operation Manual Download Page 5

26

3

Safety Precautions

Dear users:
Thanks for your choice of Haier pharmaceutical refrigerator; please make sure you have carefully 
read and observed the contents with following signs in the manual, for better understanding of this 
manual and better use of this product, so as to prevent personal injuries and refrigerator damage.

Ignoring this warning may result in 

death or serious injury

Ignoring this warning may result in 

death or serious injury,and/or damage

to the refrigerator and property

Actions or operations 

which are prohibited

Actions or operations 

which must be followed

If the power line needs to be extended, the extended line shall be no smaller than 2mm² in 

sectional area and no longer than 3m in length. Otherwise, fire or electric shock may be 

caused.
The power line for this refrigerator is provided with a standard three wire (grounding) plug, 

which complies with 16A. Do not remove or dismantle the grounding pin of power line in 

any case. Make sure the power plug is securely and reliably plugged into the socket to 

prevent fire.

Apply socket with ground wire to prevent electric shock.If the socket fails to be grounded, 

ground wires must be installed by professional technical staffs.

The refrigerator shall not conduct outdoor service. Electrical leakage or shock may be 

caused if wet by rainwater.
Do not place the refrigerator in humid places or places where the refrigerator may suffer 

splashing water, to prevent electric leakage or shock due to deterioration of insulation.

Do not pour water on the refrigerator to prevent electric shock or short circuit.

In case of flammable gas leakage such as coal gas, shut off the valve of leaked gas, open 

windows for ventilation and exhaust; do not plug in or pull out the power plug of refrigerator 

to prevent explosion and fire.
The refrigerator shall be installed by professional technical staffs or after-sale maintenance

staffs to prevent electric shock or fire.
Place the refrigerator on solid and flat ground in a stable manner. The refrigerator will be 

tipped over or personal injuries will be caused if the refrigerator is placed on improper 

ground or place.

Apply the dedicated power supply marked on the nameplate of refrigerator to prevent fire 

or electric shock.
If the voltage being used is 10% higher or lower than rated voltage , automatic voltage 

regulator above 4000W and appropriate for motor load shall be installed.

1440×910×1980

1320×700×1500

1378L

Pharmaceutical Refrigerator

Outside Dimensions

(W×D×H) 

(mm)

Inside Dimensions

(W×D×H) 

(mm)

Effective Volume

Door

Foaming Material

Compressor

Shelf

Refrigerating Method

Outer Plate /Inner Plate

Condenser/Evaporimeter

Refrigerant

Lamp

Net Weight

Temperature of Monitoring Bottle

Rated Power Supply

Rated Power/Current

Alarm Equipment

High & low temperature alarm, sensor fault alarm, 

power failure alarm, Low battery alram, door opening alarm

Name

Model

EL-RG-49H

R134a   490g  

310kg

2

~8

Duration of Outage Alarm

48 h (when the battery is fully charged)

Type of Electric-shock Safeguard

I

220V-240V~/50Hz

800W/4.2A

Temperature Controller

Specification

Specification

Glass door with electric heat

Rigid polyurethane foam (fluoride-free)

Fully enclosed compressor

12

Force-air cooling circulation

Cold-rolled steel with power cover

Finned pipes / Finned pipes

Computer control system

LED  5W

Power connection type

Y

Climate Type

4

Foaming Agent

CP/IP

Noise Level

43dB(A)

The loading of each shelf

Max:30kg/m²

Note: Climate Type 4 means the temperature is +30

,the relative humidity is 55%.

Testing hole

2

R134a   490g  

220V-240V~/60Hz

800W/4.2A

R134a   490g  

115V~/60Hz

950W/11A

48dB(A)

Rechargeable Battery

DC 12V rechargeable battery

Summary of Contents for EL-RG-49H

Page 1: ...or may vary Translation of the original instruction The scope of the Product Application Pharmaceuticals and other related products which need a storage environment of 2 8 Certi cate of Quality Pharma...

Page 2: ...harmaceutical Refrigerator Type Designation Trademark EL RG 49H Manufactures Name Aegis Scientific Inc Address Tel 1 Ivybrook Blvd Unit 145R Ivyland PA 18974 USA 1 800 796 2344 Fax 732 879 0248 Refer...

Page 3: ...essor and main components and better refrigeration performance User friendly design computer control smart and carefree adjust ment not required High performance thermal insulation layer with excellen...

Page 4: ...the appliance that you have just purchased due to technical improvements 1 Product Feature Content Safety Precautions Precautions for Use Product Installation Component Names Control Panel Applicatio...

Page 5: ...ug in or pull out the power plug of refrigerator to prevent explosion and fire The refrigerator shall be installed by professional technical staffs or after sale maintenance staffs to prevent electric...

Page 6: ...ay pose danger to human health or environment Pull out the power plug if the refrigerator has been out of service for long time to prevent electric shock leakage or fire caused by aging power lines If...

Page 7: ...ust be placed on a solid and flat surface or excessive vibration and noise may be produced when the appliance in operation The appliance can be used by children aged from 8 years and above and persons...

Page 8: ...hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new ones the retailer is legally obligated to tak...

Page 9: ...ion site Do not ground the refrigerator through gas pipes water supply pipes telephone lines or lightning conductors as electric shock may be caused The power plug can be accessed after installation t...

Page 10: ...ownward upward Clean the back evaporating box Evaporating box is installed on the back of the refrigerator Remove 2 screws on the bottom loosen the upper 2 screws no need to remove them lift the evapo...

Page 11: ...m is under normal condition When chargeable battery is closed or with too low a power press once the alarm testing key E6 is expected to flash 3 times on the display window at the simultaneously The r...

Page 12: ...220V 110V failed under any of the above conditions remote alarm shall be started Coupled with 1Hz continuous beeping Take corres ponding measures according to item 1 2 and 3 Remote alarm startup when...

Page 13: ...upper or lower temperature displayed ALH Alarm Limit High settable by the user high temperature alarming is triggered while when any of upper or lower temperature shown ALL Aalrm LImit Low settable by...

Page 14: ...inside temperature display area flashes Date press Minus button or Plus button to adjust the current date and the press Set button to save and confirm Thereafter the inside temperature display area sh...

Page 15: ...e display area steadily shows 2P press Set button the inside temperature display area flashes Month factory default 01 press Minus button or Plus button select Month from 01 12 recycling display after...

Page 16: ...arameter value After setting press Set to go back and choose other parameters for the same token With all values set press Set button 5s exit and return to the normal display mode Temperature Display...

Reviews: