.2.3 OPERATING (NAVIGATION) 

The 4 keys for navigation control the following functions: 

” Key:

Press this key to scroll upwards in the menu levels or 
to alter a value you want to set. 

 If you press this key in the status display, you will 

access the  UPS On or O  menu item. 

”Key:

Press this key to scroll downwards in the menu levels 
or to alter a value you want to set. 

ENTEr   ey: Press this key brie y to select the corresponding 

menu item. To confirm and store a menu item in the 

“Settings” menu, press this key and hold it down for at 
least 1 second. 

“ESC” Key: Press this key to return to the previous menu level 

without altering any settings. If you press this key in 
the status display, you will access the main menu. 

You can also temporarily disable a notice warning tone by pressing  
any key. 

If no key is pressed, the display returns automatically back to the 
standard display after 5 minutes. Shoul

d you want to recall a specific 

reading - press "freeze" menu for about 3 seconds at the same time  
with the "

" and "

" buttons. A small key in the upper right display 

indicates the setting. A new simultaneous operation of these two 
buttons for 3 seconds re-cancels the setting. 

Summary of Contents for PROTECT C Series

Page 1: ...PrOTECT C User Manual Protect C 1000 Protect C 2000 Protect C 3000 EN DE ...

Page 2: ......

Page 3: ...lutions entschieden haben Die nachfolgenden Sicherheitshinweise sind wichtiger Bestandteil der Betriebsa nleitung und werden Sie vor Problemen durch Fehlbedienung oder vor möglichen Gefahren schützen Lesen Sie deshalb diese Anleitung vor der ersten Inbetrieb nahme sorgfältig durch ...

Page 4: ...lungsort Übersicht Anschlüsse Bedien Anzeigeelemente 1 Vorderansicht 2 r ckseitige Ansicht Anschl sse Aufstellung Erweiterung durch externe Batteriemodule Netzanschluss Verbraucheranschluss Betrieb und Bedienung Erstinbetriebnahme USV einschalten USV ausschalten Bedientableau berblick Indikatoren LED An eigen Bedientasten Navigation Display auptmen USV Status Anzeige Ereignisprotokoll 6 8 8 9 11 1...

Page 5: ...rgung 1 Lagerung 1 2 Demontage 1 3 Entsorgung 1 Anhang 1 1 2 DE Computer Schnittstellen RS232 und USB Kommunikationsslot Shutdown und USV Management Software Notabschaltung EPO Emergency Power O Batterie laden Kontrollen Sichtkontrolle Batteriekontrolle Lüfterüberprüfung Sachwortver eichnis technische Begri e Stichwortregister 4 4 4 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 5 6 ...

Page 6: ...men warten oder sonstige Arbeiten an diesem Gerät verrichten Diese Betriebsanleitung entspricht dem technischen Stand des PROTECT C zur Zeit der Herausgabe Der Inhalt ist nicht Vertrags ge genstand sondern dient der Information Änderungen der Angaben dieser Betriebsanleitungen insbesondere der technischen Daten und der Bedienung bleiben jeder eit vorbehalten reklamationen ber gelieferte Waren bitt...

Page 7: ... zu erleichtern sind einigen Bearbeitungsschritten Bilder zugeordnet Sind bei bestimmten Arbeiten Gef hrdungen f r Personen und Material nicht aus uschlie en werden diese T tigkeiten durch Piktogramme ge kenn eichnet deren Bedeutung den Sicherheitsbestimmungen in Kapitel 3 zu entnehmen ist COPYRIGHT Weitergabe Vervielf ltigung dieser Betriebsanleitung und oder bernahme mittels elektronischer oder ...

Page 8: ...nd Net r cks peiseschutz Gleichrichterteil mit PFC Logik Leistungsfaktorkorrektureinheit Separatem Batterieladegleichrichter in Schaltnetzteil Technologie Batteriesystem in verschlossener wartungsfreier Ausführung als Energiespeicher mit nachgeschalteter DC DC Wandlereinheit IGBT Wechselrichter zur kontinuierlichen Versorgung angeschlossener Verbraucher mit sinusförmiger Wechselspannung Automatisc...

Page 9: ... die Batterie erheblich ein us t licher ruhemodus erh ht merklich die Nut ungsdauer der Batterie Der Wechselrichter bernimmt die Umwandlung der Gleichspannung in eine sinusf rmige Ausgangsspannung Eine mikro pro essorgesteuerte regelung auf Ba sis einer Pulsweitenmodulation PWM garantiert in Verbindung mit digi taler Signalpro essortechnik und extrem schnell pulsierenden IGBT Leistungshalbleitern ...

Page 10: ...ng direkt und unterbrechungsfrei auf den Verbraucher durchschaltet Der automatische Bypass stellt somit für den Verbraucher eine zusätzliche passive redundan dar Eine vielseitige Verwendung und einfache Bedienung wird schließlich durch das eingeset te grafische LC Display erreicht Ein Notabschalt kontakt erg n t die standardm ige Schnittstellenvielfalt USB rS232 ommunikationsslot ...

Page 11: ...eichrichter Spgs bereich ohne Batteriebetrieb 50 Last cosφ 0 8 ind 110 300 VAC Frequenz 50 Hz 60 Hz autom Erkennung oder manuell Frequenztoleranzbereich 10 Stromaufnahme bei PF0 9 Volllast max Protect C 1000 5 4 5 2 5 0 A UN 220 230 240 VAC UN 220 230 240 VAC UN 220 230 240 VAC Protect C 2000 10 0 9 6 9 2 A Protect C 3000 14 7 14 1 13 5 A Bypass Spannungsbereich 176 VAC 264 VAC Netzrückwirkungsfak...

Page 12: ...0 für 60 s 110 125 für 30 s 125 150 für 10 s Wenn Netz vorhanden anschließend automatische Umschaltung auf integrierten Bypass in 4 ms Rückschaltung bei abklingender Überlast Last 70 Überlastverhalten Bypass Bis 125 kontinuierlich 125 150 10 min Kurzschlussverhalten 3 x I Nfür 100 ms Batterie Überbrückungszeit Gekoppelte Batteriemodule cos 0 8 ind 100 geladene Batterie C 1000 C 2000 C 3000 mit int...

Page 13: ...te SNMP Pro Fernabschaltkontakt poten ialfrei wahlweise als ner oder Schließer programmierbar Shutdown Software PNQV8BUDIhor 8JOQPXFS für alle gängigen Betriebssyteme u a Windows Linux Mac Unix Novell Sun Allgemeine Daten Klassifikation VFI SS 111 gem IEC 62040 3 Dauerwandlertechnologie INV BATT VFI SS 311 gem IEC 62040 3 ECO Betriebsart Volllast Wirkungsgrad AC AC DC AC Protect C 1000 87 85 Protec...

Page 14: ...3 Protect C 2000 6 x IEC 320 C13 Protect C 3000 4 x IEC 320 C13 1 x IEC 320 C19 1 Festanschluss über Klemmstein Display Grafik LC Display Au sung 128 x 4 Pixel Sprachen DE EN ES Fr rU us 3 LEDs ur Betriebsan eige Gehäusefarbe Blackline Gewichte netto brutto Protect C 1000 13 kg 15 kg Protect C 1000 BP 18 kg 19 kg Protect C 2000 31 kg 33 kg Protect C 3000 31 kg 33 kg Protect C 2030 BP 44 kg 4 kg Ab...

Page 15: ...linien Für 2014 35 EU Niederspannungsrichtlinie Referenznummer EN 62040 1 2008 Für 2004 108 EG EMV Richtlinie Referenznummer EN 62040 2 2006 Klasse C1 Der Protect C entspricht der Produktnorm EN 62040 Das CE Zeichen am Gerät bestätigt die Einhaltung der EG Nieder spannungsrichtlinie 2014 35 EU sowie der EMV Richtlinie 2004 108 EG für elektromagnetische Verträglichkeit wenn die in der Betriebsanlei...

Page 16: ...nd von Transportschäden sind grundsätzlich gegenüber dem Transportunternehmen geltend zu machen Prüfen Sie daher bei Erhalt den Versandbehälter auf Schäden Wenn nötig bitten Sie das Transportunternehmen die Waren zu prüfen und nehmen Sie den Schaden in Anwesenheit des Mitarbeiters des Trans portunternehmens auf um ihn innerhalb von acht Tagen ab Lieferung über den AEG Repräsentanten bzw Händler zu...

Page 17: ...messene Umgebungsbedingungen Der Protect C ist luftgek hlt Versperren Sie die Be und Entl ftungs nungen nicht Die USV und deren externe Batteriemodule sollten vorzugsweise bei Raumtem peratur zwischen 15 C und 25 C betrieben werden Stellen Sie die Geräte in einem Raum auf der trocken relativ staubfrei und frei von chemischen Dämpfen ist Stellen Sie sicher dass keine magnetischen Speichermedien in ...

Page 18: ... 1 VORDERANSICHT Protect C 1000 Protect C 2000 Protect C 3000 Protect C 1000 BP Protect C 2030 BP ÜBERSICHT ANSCHLÜSSE BEDIEN ANZEIGEELEMENTE 1 ...

Page 19: ... 2 RÜCKSEITIGE ANSICHT ANSCHLÜSSE Protect C 1000 Protect C 2000 Protect C 3000 DE 1 ...

Page 20: ...ranschlüsse USV Abgänge IEC 320 C13 10 A 10 Getrennte Absicherung der Laststromkreise beim PROTECT C 3000 11 Verbraucheranschluss PROTECT C 3000 USV Abgang IEC 320 C19 16 A 12 Verbraucheranschluss PROTECT C 3000 USV Abgang über Klemmleiste berwachte r L fter mit intelligenter Dreh ahlregulierung Achtung 100 mm Mindestfreiraum hinter dem L fter um freien Ausblasen beachten Die USB und rS232 ommunik...

Page 21: ...inheiten so anordnen dass seitliche uluft nungen der USV Anlage nicht abgedeckt werden ur Wahrung maximaler mechanischer Stabilit t sollte von einer direkten Aufstellung der exter nen Batterieeinheit en oberhalb oder unterhalb der USV Anlage ab gesehen werden Extreme Temperaturen vermeiden Um die Gebrauchsdauer der Bat terien u maximieren ist eine Umgebungstemperatur von 15 C bis 25 C u empfehlen ...

Page 22: ...t C 3000 mit Protect C 2030 BP Überprüfen Sie die korrekte Zusammengehörigkeit von USV und Batterieeinheit die Gehäuse müssen z B von den Abmessungen her identisch sein Verbinden Sie mit der beiliegenden Batterieanschlussleitung die entsprechenden Batteriekonnektoren gemäß obiger Abbildung Achten Sie beim Anschluss darauf dass die Stecker zügig und fest in die Batteriekonnektoren eingesteckt werde...

Page 23: ...d fest in die Batteriekonnektoren eingesteckt werden Fixieren Sie die Steckerteile abschließend mit den seitlichen Schrauben Ändern Sie im Menüpunkt Einstellungen unter Externe Batteriemodule die Anzahl auf 2 s a Seite 1 2 3 3 NETZANSCHLUSS Überprüfen Sie die Kompatibilität der USV Nenneingangsspannung mit der für Ihr Land geltendenNennspannung Die sich USV seitig automatisch einstellende Ausgangs...

Page 24: ...enden Sie hierfür die beiliegenden Verbraucheranschlusslei tungen Ihre Verbraucher lassen Sie zunächst in ausges chaltetem Zu stand Sollten weitere Verbraucheranschlussleitungen erforderlich werden kontaktieren Sie bitte Ihren Fachhändler Im Fall eines gemeinsamen Verteilerschrankes Stromkreise sowohl mit Netz wie auch USV Spannung kennzeichnen Sie jeden Stromkreis mit der jeweiligen Speisung Netz...

Page 25: ...f eine abschaltende St rung hin Folgen Sie den Anweisungen in apitel 1 ontrollieren Sie abschlie end den festen Sit der im Notab schaltstecker befestigten Drahtbr cke und iehen Sie die beiden u eren Schrauben des Steckerteils fest an s a Seite Pos M chten Sie die Funktion der Notabschaltung nut en so fahren Sie un chst mit apitel 4 auf Seite 4 fort Die verbaute Notabschaltung dient lediglich der A...

Page 26: ...estellte Befehlsau orderung UPS On best tigen Sie nun durch Dr cken der Taste ENTEr alten Sie die Taste f r ca 1 Sekunde gedr ckt Die USV synchronisiert sich und nimmt nach wenigen Sekunden den Normalbetrieb auf Das Display wechselt zur USV Status Anzeige Erfolgt f r 5 Minuten keinerlei Tastenbet tigung wechselt die An eige automatisch ur USV Status An eige r ckkehr durch Tastendruck 1 2 USV AUSSC...

Page 27: ...stemfehler Gelb und Grün permanent leuchtend Batteriebetrieb Grün blinkend Bypassbetrieb ECO Betrieb Grün permanent leuchtend Normalbetrieb Dauerwandler 2 BEDIENTABLEAU 2 1 ÜBERBLICK Wesentliches Merkmal des Bedientableaus ist dessen grafisches LC Display mit lartextan eige Im unteren Bereich befinden sich 4 Tasten ur Men navigation der obere Bereich beinhaltet us t lich 3 verschiedenfarbige LEDs ...

Page 28: ...stellungen halten Sie diese Taste für mindestens 1 Sekunde gedrückt Drücken Sie diese Taste zur Rückkehr zur vorherigen Menüebene ohne dass Sie Einstellungen verändern möchten Drücken Sie diese Taste während der Statusanzeige so gelangen Sie zum Hauptmenü Weiterhin können Sie durch Drücken einer beliebigen Taste einen Hinweis Warnton vorübergehend deaktivieren Erfolgt keine Tastenbetätigung kehrt ...

Page 29: ...ufgerufen indem Sie im Hauptmenü mit den Tasten oder zum Menüpunkt USV Status navigieren Zeile wird dabei invertiert dargestellt und anschließend die ENTER Taste betätigen autom Anzeige nach 5 min Die USV Status Anzeige unterteilt sich in mehrere Abschnitte mit folgenden abrufbaren Informationen Zusammenfassende Anzeige aller anwenderrelevanten Ein und Ausgangspa rameter einschließlich der Info üb...

Page 30: ...rgt die Verbraucher ber den integrierten Bypass USV arbeitet im Frequen wandlermodus USV befindet sich in Betriebsbereitschaft Standby Mode eine Ausgangs spannung Bypass deaktiviert USV arbeitet in der Betriebsart konomisch ECO Betrieb Das Display eigt mittig im oberen Bereich den aktuellen USV Status an Finden Sie im Folgenden eine Aufstellung der verwendeten Symbole und deren Bedeutung ...

Page 31: ...ch durchgeführtem Batterietest USV meldet fehlerhaftes bzw nicht angeschlossenes Batteriesystem USV ist überlastet USV zeigt kritischen Fehler und hat den USV Ausgang abgeschaltet Genereller USV Alarm Details ersichtlich aus den Alarmmeldungen und Einträgen im Ereignisprotokoll DE 1 ...

Page 32: ...aktiert Teil 2 der USV Status Anzeige erreichen Sie nach Drücken der Taste und beinhaltet aktuelle Mitteilungen und ggf anstehende Alarmmeldungen Jede Mitteilung bzw jeder Alarm wird in einem eigenen Fenster dargestellt und sequentiell durch Drücken der Taste aufgerufen Stehen keine Informationen an so erscheint die Meldung Keine Alarmmeldungen Ereignisse werden ausschließlich im Ereignisprotokoll...

Page 33: ...h die Gesamtan ahl bereits gespeicherter Ereignisse sowie Ihre der eitige Position beim Durchscrollen der Fenster 1 gibt dabei das aktuellste ulet t gespeicherte Ereignis wieder Startposition beim Aufruf Wurden noch keine Ereignisse gespeichert b w wurde der Ereignisspei cher gel scht s a apitel 3 auf Seite 4 so erscheint die Mel dung eine Ereignisse im Speicher Aufruf des Ereignisspeichers Das Er...

Page 34: ...timmten Messwer tes so können Sie die aufgerufene Anzeige im Messwerte Menü ein frieren Drücken Sie hierfür für ca 3 Sekunden gleichzeitig die Tasten und bis ein kleiner Schlüssel im oberen rechten Displaybereich erscheint Eine erneute gleichzeitige Betätigung dieser beiden Tasten für ca 3 Sekunden hebt die Einstellung wieder auf 3 4 STEUERUNG Während des Normalbetriebszustandes können Sie nach Au...

Page 35: ...h jederzeit Abbruch möglich Fehlerspeicher löschen Zu rücksetzen von Alarmmeldungen Löscht manuell alle aufgelaufenen Alarmmeldungen wie z B Batteriefehler detektiert oder aber Zwischenkreisspgs abweichungen Bei aktivem Batteriefehleralarm wird gleichzeitig auch der Status des Batterietests zurückgesetzt auf nicht getestet 3 5 IDENTIFIKATION Durch Aufruf dieses Menüpunktes können Sie sequentiell d...

Page 36: ...nommen und bleibt dauerhaft gespeichert auch z B bei einem auftretenden Netzausfall Diese Einstellung unterscheidet sich völlig vom Feature der vorübergehenden Alarmunter drückung Durch Drücken einer beliebigen Taste während eines anstehenden akustischen Alarms würde dieser zeitweise zwar ebenfalls unterbunden würde jedoch erneut bei Auftreten eines weiteren au lligen Ereignisses erneut ertönen ak...

Page 37: ...s frequenz 50Hz 60Hz automatische Erkennung Menüpunkt nur im USV Betriebsbereitschaftsmodus Standby mode verfügbar automatische Erkennung Alarm Niveau Überlast 10 20 30 100 Anm Die Einstellung kann feinfühlig in 10 Schritten gewählt werden sodass frühzeitig eine evtl Über lastung der USV erkannt wird 100 Funktionsweise Betriebsart Beste Leistung Normalbetrieb Ökonomisch ECO Betrieb Frequenzumricht...

Page 38: ...ischer Batterietest wird wiederkehrend entspre chend der Einstellung Periodischer Batterietest ausgeführt Während dieses Batterietests wird das Batteriesystem für ca 10 Sekunden mit der aktuell anliegenden Last entladen Bei einem automatisch durchgeführten Batterietest erfolgt keine Meldung USV im Batteriebetrieb und auch eine ggf anstehende Batterieunterspannungsmeldung während des Batteriesystem...

Page 39: ...f gbar ner N C kWh Zähler zurücksetzen nein ja Bei Auswahl nein keine Ver nderung Bei Auswahl ja werden die aufgelaufenen kWh ur ckgeset t Zählerneustart bei aktuellem Zeit Datumseintrag nein Limitierung Batteriebetrieb 5h h 14h 15h 1 h 999h inaktiv Wird das gew hlte eitfenster im USV Batteriebetrieb berschritten wird unabh ngig vom aktuellen Batteriespgs level eine Unterspgs meldung ausgegeben we...

Page 40: ...icherter Ereignisse Eine erneute Betätigung der Taste ENTER setzt die Anzahl dann auf 0 zurück LCD Kontrast 5 4 1 0 1 4 5 0 Wiederher stellung der Werksein stellungen nein ja Menüpunkt nur im USV Betriebs bereitschaftsmodus Standby mode verfügbar Wiederherstellung Werkseinstellungen setzt alle Anwendereinstellungen auf die Werkseinstellungen zurück setzt alle anstehenden Befehlsein stellungen zurü...

Page 41: ... 2 TxD 3 RxD 5 GND 2 KOMMUNIKATIONSSLOT Auf der r ckseite der USV befindet sich eine Abdeckung s Pos 7 auf Seite 24 nach deren Entfernen sich dort zusätzliche optional er hältliche Kommunikations komponenten installieren lassen z B Einsteckkarte mit Statusmeldungen realisiert über poten ialfreie relaiskontakte ner oder Schlie er Anschluss über Sub D9 wie oben jedoch Belegung programmierbar Anschlu...

Page 42: ... FTT LBOO XFJ WFSTDIJFEFOF ÕTVOHFO WPSTDIMBHFO SXFJUFSUFT 4PGUXBSFQBLFU PNQV8BUDI JUF 4PGUXBSFQBLFU 8JO1PXFS 8FJUFSF OGPSNBUJPOFO GJOEFO 4JF BVG VOTFSFS 8FCTFJUF XXX BFHQT DPN VOUFS 1SPEVLUF CFSXBDIVOHTMÕTVOHFO PSU LÕOOFO 4JF 4PGUXBSFQBLFUF VOE PLVNFOUBUJPOFO IFSVOUFSMBEFO 8JO1PXFS PNQV8BUDI DE ...

Page 43: ...n Sie diese aus Entfernen Sie das Steckerteil aus dem EPO Einsatz auf der Rückseite der USV durch Lösen der 2 äußeren Schrauben s a Seite Pos 6 Verbinden Sie einen poten ialfreien ner ontakt Belastbarkeit mindestens 60 VDC 30 VAC 20 mA mit den Pins des Steckerteils Verwenden Sie hierbei eine exible Leitung mit einem abel querschnitt von min 0 5 mm2 b w max 2 5 mm2 Stecken Sie den Stecker wieder au...

Page 44: ...gt PROBLEMBEHANDLUNG 1 STÖRUNGEN Der Protect C setzt detaillierte Fehlermeldungen ab mit denen Sie oder das Servicepersonal schnell und präzise auftretende Störungen lo kalisieren und deuten können Finden Sie nachstehend Verfahrens Lö sungsvorschläge zur Behebung des anstehenden Problems Sollten Sie keine Lösung des aufgetretenen Problems herbeiführen kön nen beenden Sie den gesamten Vorgang schal...

Page 45: ...nungswarnung Alarm 56 Intermittierender Signalton Verbleibende Über brückungszeit verbleibende Batterie kapazität neigt sich dem Ende zu und unterschreitet den USV intern spe ifi ierten Schwellwert Warnsignal als letzter Warnhinweis zur kurz bevorstehenden Ab schaltung Zeitpunkt variiert da abhängig von anliegender Last und Anzahl kontaktierter Batteriemoduleinheiten Anstehender Shut down Abschalt...

Page 46: ...g Eingang Alarm 7 Intermittierender Signalton Netzspannungsver sorgung außerhalb Toleranz Betriebszustandsbe zogen wechselt die USV in den Batteriebetrieb bzw schaltet ab Frequenzab weichung Eingang Alarm 8 Intermittierender Signalton Frequenz der Netz spannung außerhalb des Toleranzbereiches Betriebszustandsbe zogen wechselt die USV in den Batteriebetrieb bzw schaltet ab Phasenfehler Fehler in Ne...

Page 47: ...34 Kontinuierlicher Signalton Fehler im internen Batterieladeteil der USV detektiert Batterieladeteil wurde elektronisch deaktiviert Setzen Sie sich mit Ihrem Händler in Verbindung Ausgangsseitiger Kurzschluss Alarm 58 Intermittierender Signalton Die USV hat einen extrem niederohmigen Verbraucher detektiert und als Kurzschluss gewertet USV versucht den Kurzschluss zu löschen und funktioniert als K...

Page 48: ...erfunktion prüfen ggf Lüfter tauschen Setzen Sie sich mit Ihrem Händler in Verbindung Schwerwiegender EEPROM Fehler Alarm 53 Kontinuierlicher Signalton Überprüfung der im EEPROM abgelegten Daten fehlerhaft ggf hervorgerufen durch ein nicht erfolgreich verlaufendes Firmware Update Flash Prozess Flash Datei überprüfen Flash Prozess danach erneut durchführen Bleibt das Problem bestehen setzen Sie sic...

Page 49: ...eichabsicherung und die Sicherheitsvorschriften unbedingt be achten 1 BATTERIE LADEN Die Batterie wird automatisch durch die Präsenz des Netzes unabhän gig von der Betriebsart geladen Die komplette Au ade eit der Batterie nach einer l ngeren Entladezeit hängt insbesondere von der Anzahl der zusätzlichen externen Batterieeinheiten ab s a Kapitel 2 3 auf Seite 13 2 KONTROLLEN Folgende Wartungsarbeit...

Page 50: ...tte unsere Hotline 2 3 LÜFTERÜBERPRÜFUNG Die L fter sind regelm ig auf Staubanfall und au allend untypische Ge r us chentwicklung u berpr fen Bei verstopften uluft nungen sind diese u reinigen bei ungewöhnlich lautem oder unruhigem Lauf kontak tieren Sie bitte unsere Hotline 3 BATTERIEWECHSEL Achtung Eine Batterie kann Ursache für einen elektrischen Schock sein und kann bei unsachgemäßer Behandlun...

Page 51: ...ten Entsorgen dieser Akkumulatoren schützen Sie die Umwelt und die Gesundheit Ihrer Mitmenschen Umwelt und Gesundheit werden durch falsches Entsorgen gefährdet Materialrecycling hilft den Verbrauch von rohsto en u verringern Bei Produkten die aufgrund ihrer Sicherheit vor Datenver lust eine ständige Verbindung zur eingebauten Batterie benötigen sollte die Bat terie nur durch qualifi iertes Service...

Page 52: ...h der Montagebeschreibung in umgekehrter reihenfolge 1 3 ENTSORGUNG FS GPMHFOEF CTDIOJUU HJCU IOFO JOXFJTF XJF EJF FJO FMOFO PNQPOFOUFO EFS OMBHF FOUTPSHU XFSEFO s 7FSQBDLVOH OUTPSHFO 4JF EJF 4USFUDIGPMJF VOE EJF PSNUFJMF BVT 1PMZFUIZMFO 4DIBVNTUPGG ÛCFS EFO OPSNBMFO OEVTUSJFBCGBMM 4JF TJOE DIFNJTDI JOBLUJW VOE MBTTFO TJDI FOUTPSHFO PEFS SFDZDFMO s FUBMMUFJMF CFSHFCFO TJF EJF FUBMMUFJMF FJOFN MUNF...

Page 53: ... WPS 0SU HÛMUJHFO FTFU FO VOE 7PSTDISJGUFO FOUTPSHFO 7FSCSBVDIUF BUUFSJFO PEFS BUUFSJFNBUFSJBM LFJOFTGBMMT JO EFO ÛMM XFSGFO FGPMHFO 4JF EJF WPS 0SU HÛMUJHFO FTFU F VOE 7PSTDISJGUFO GÛS EJF BHFSVOH BOEIBCVOH VOE OUTPSHVOH WPO BUUFSJFO VOE BUUFSJFNBUFSJBM DE 5 ...

Page 54: ...nd dem sog Ger teschut lasse D ochleistungsf hige Transistoren modernster Bauart mit geringstem Steuerleistungsbedarf MOSFET Struktur und geringsten Verlusten auf der usgangsseite Struktur eines bipolaren Transistors Elektronisches albleiter Bauelement im Sprachgebrauch als Leuchtdiode be eichnet Verwendung ur optischen Signalisierung Schaltungstechnik ur Minimierung von Net r ckwirkungen insbeson...

Page 55: ...ungen jedoch wird die Netzspannung durch elektronische passive Spannungsregelgeräte aufbereitet Frühere Bezeichnung LINE INTERACTIVE VFI Output Voltage and Frequency Independent from mains supply Der USV Ausgang ist unabhängig von Netzspannungs und Frequenzschwankungen Frühere Bezeichnung ONLINE DE 5 ...

Page 56: ...ngen G Geräteüberlast Gewichte H Hotline I Erst Inbetriebnahme Indikatoren K PNNVOJLBUJPOTTMPU 14 3 14 4 L Lagerung Lieferumfang M FTTXFSUF N Netzanschluss Normalbetrieb Notabschaltung R Richtlinien S Schnittstellen PC Sicherheitshinweise Störungen Systembeschreibung T Technische Daten U Überbrückungszeit Überlast USB 7 Verbraucheranschluss 15 9 11 12 12 1 2 STICHWORTREGISTER ...

Page 57: ...NOTIZEN DE ...

Page 58: ...NOTIZEN ...

Page 59: ...NOTIZEN DE ...

Page 60: ... ...

Page 61: ...AEG UPS PROTECT C from AEG Power Solutions Safety information and operating instructions are included in this manual To ensure correct use of the UPS please read this manual thoroughly before operating it Use this manual properly EN ...

Page 62: ...play Elements 1 Front View 2 Rear View Connections Commissioning 1 Mechanical Set Up 2 External Battery Extension 3 Power Supply 4 Consumer Connection Operation and usage 1 Initial Installation 1 1 Switching on UPS 1 2 Switching o UPS 2 Control Panel 2 1 Overview 2 2 Indicators LEDs 2 3 Operating Navigation 3 Display Main Menu 3 1 UPS Status Display 3 2 Event Log 3 3 Measurements CONTENT 6 3 4 Con...

Page 63: ...ftware 4 EPO Emergency Power O Trouble Shooting 1 Malfunctions 1 1 Alarm Error messages Maintenance 1 Battery Charging 2 Maintenance 2 1 Visual Check 2 2 Checking the Battery 2 3 Fan Checking 3 Battery replacement Storage Dismantling and Disposal Glossary 1 1 Technical Terms 1 2 ey Word register 1 4UPSBHF JTNBOUMJOH JTQPTBM ...

Page 64: ... operating instructions comply with the current technical specifications of the PROTECT C at the time of delivery The contents do not constitute a subject matter of the contract but serve for information purposes only We reserve the right to alter any specifications given in these operating instructions especially with regard to technical data and operation prior to start up or as a result of serv...

Page 65: ...ersonnel Illustrations are provided to clarify and facilitate certain steps If danger to personnel and the unit cannot be ruled out in the case of certain work it is highlighted accordingly by pictograms explained in chapter 3 COPYRIGHT No part of these operating instructions may be transmitted reproduced and or copied by any electronic or mechanical means without the express prior written permiss...

Page 66: ...protection class D and mains energy backfeed protection rectifier section with PFC logic power factor correction unit Separate battery charger with switch mode power supply technology Sealed maintenance free battery system as energy storage medium with downstream DC DC converter unit IGBT inverter for continuous supply of connected loads with sinusoidal AC voltage Automatic bypass as additional pa...

Page 67: ...ntent of the charging current for the battery is almost ero so the service life of the battery is increased even more The inverter is responsible for converting the DC voltage into a sinusoidal output voltage A microprocessor controlled control system based on pulse width modulation PWM in conjunction with an extremely quickly pulsating IGBT power semiconductors of the inverter guarantee that the ...

Page 68: ... load if there is an inverter malfunction As a result the automatic bypass represents an extra passive redundan cy for the load The graphical LC display used provides for versatile use and easy operation Such a convenient feature as an emergency power o contact round out the standard interface selection USB RS232 communication slot ...

Page 69: ...voltage range without battery operation 100 load cosφ 0 8 lag 176 300 VAC Rectifier voltage range without battery operation 50 load cosφ 0 8 lag 110 300 VAC Nominal frequency 50 Hz 60 Hz autom detection or manual Frequency tolerance 10 Power consumption at PF0 9 full load max Protect C 1000 5 4 5 2 5 0 A UN 220 230 240 VAC Protect C 2000 10 0 9 6 9 2 A UN 220 230 240 VAC Protect C 3000 14 7 14 1 13...

Page 70: ...EC sockets Crest factor 3 1 Overload behaviour up to 105 continuous 105 110 for 60 s 110 125 for 30 s 125 150 for 10 s Then automatic inverter to Bypass in 4 ms switches back when overload damps Load 90 Overload bypass Up to 125 continuous 125 150 10 min Short circuit 3 x I Nfor 100 ms Battery Autonomy Time External battery module cosφ 0 8 lag 100 charged battery C 1000 C 2000 C 3000 With integrat...

Page 71: ...ial free optionally programmable as opener or closer Shutdown Software CompuWatch PS 8JOQPXFS for all popular operating systems like Windbows Linux Mac Unix Novell Sun General data Classification VFI SS 111 acc to IEC 62040 3 double conversion technology INV BATT VFI SS 311 acc to IEC 62040 3 ECO mode ull load e icienc AC AC DC AC Protect C 1000 87 85 Protect C 2000 88 85 Protect C 3000 88 85 ull l...

Page 72: ...1 x IEC 320 C19 1 fixed connection on terminal block Display Graphic LCD resolution 128 x 64 pixels Languages DE EN ES FR RU 3 LEDs for power indication Equipment color Blackline Weight net gross Protect C 1000 13 kg 15 kg Protect C 1000 BP 18 kg 19 kg Protect C 2000 31 kg 33 kg Protect C 3000 31 kg 33 kg Protect C 2030 BP 44 kg 46 kg Dimensions W x H x D net Protect C 1000 145 mm x 220 mm x 400 m...

Page 73: ...ROTECT D complies with the EN 62040 product standard The CE seal on the device confirms that the device complies with the following directives EG Low Voltage Directive 2014 35 EU as well as the EMC Directive 2004 108 EG for electromagnetic compatibility if the installation instructions provided in this manual are followed For 2014 35 EU Low Voltage Directive Reference number EN 62040 1 2008 For 20...

Page 74: ...e transport company to check the goods and make a record of the damage in the presence of the member of sta from the transport company Dont turn on the unit and register the damage with the AEG representative or dealer immediately Check the contents of the shipment for completeness PROTECT C with 1000 2000 or 3000 VA Mains connection cable with safety plug 2 device connecting cables 10 A when C 30...

Page 75: ...ted environment When installing the unit pay attention to such factors as su icient ventilation and suitable ambient conditions PROTECT C is air cooled Do not obstruct the air vents The UPS and in particular its external battery modules should preferably be operated at room temperature between 15 C and 25 C Install the units in a room that is dry relatively dust free and free of chemical vapours M...

Page 76: ... 1 FRONT VIEW Protect C 1000 Protect C 2000 Protect C 3000 Protect C 1000 BP Protect C 2030 BP OVERVIEW CONNECTIONS OPERATING DISPLAY ELEMENTS 7 ...

Page 77: ... 2 REAR VIEW CONNECTIONS Protect C 1000 Protect C 2000 Protect C 3000 EN 7 ...

Page 78: ...ot for optional expansion cards relay card remote ON OFF SNMP The USB and the RS232 communication interfaces rule each other out i e either USB or rS232 The communication slot on the other hand is dual monitor enabled i e can be used parallel to the USB or RS232 interface 8 Connection for external battery module 9 Consumer connectors UPS output IEC 320 C13 10 A 10 Separate protection of load circu...

Page 79: ...the unit There must be a gap of at least 50 mm here Set up external battery units special accessories to the side of the UPS system To ensure the greatest possible mechanical stability you should not set up the external battery unit s above or below the UPS system Avoid extreme temperatures We recommend an ambient temperature of 15 C to 25 C in order to maximise the service life of the batteries D...

Page 80: ...00 with Protect C 2030 BP Protect C 3000 with Protect C 2030 BP Check the correct fit of the UPS and the battery unit the casings e g have to have the same dimension Now connect both battery connectors using the supplied battery connection cable When connecting make sure that you push the plug quickly and firmly in the battery connectors Fix the connector parts concluding with the screws on the si...

Page 81: ...ou push the plug quickly and firmly in the battery connectors Fix the connector parts concluding with the screws on the side Change the menu item Settings under External Battery Modules to the number see 3 POWER SUPPLY Check the compatibility of the UPS nominal input voltage with the rated voltage applicable in your country The UPS automatically adjusted output voltage depends on the level of the ...

Page 82: ...cables are required please contact your dealer Before making the connection of loads to the UPS please check that the specified power rating on the type rating plate is greater than or equal to the sum of consumer services Connect the provided consumers with the outlets of your UPS To do this use the enclosed consumer connection lines Initially consumers must be turned o If additional load connect...

Page 83: ...beep indicates a deactivating fault Follow the instructions in section 1 Finally check the tightness of the emergency shut o plug mounted jumper wire and tighten the two outer screws of the contact securely see also page item 6 If you would like to use the emergency shutdown function refer first to chapter 4 on page 1 The built in emergency shutdown voltage is only for UPS shutdown This is done el...

Page 84: ...pressing ENTEr old the key pressed for approx 1 second The UPS will synchronize and switch into normal operating mode after just a few seconds The display will switch to the UPS status display If there are no keys pressed for 5 minutes the display will automatically switch back to the UPS status display Press to return 1 2 SWITCHING OFF UPS If the UPS is in operation it is possible to access the c...

Page 85: ...em error Yellow and Green permanently on Battery mode Green ashing Bypass mode ECO mode Green permanently on Normal mode double conversion 2 CONTROL PANEL 2 1 OVERVIEW An essential feature of the control panel is the graphical LCD with plain text display In the lower section 4 buttons are available for menu navigation the upper range also includes 3 di erent colored LEDs EN ...

Page 86: ...ngs menu press this key and hold it down for at least 1 second ESC Key Press this key to return to the previous menu level without altering any settings If you press this key in the status display you will access the main menu You can also temporarily disable a notice warning tone by pressing any key If no key is pressed the display returns automatically back to the standard display after 5 minute...

Page 87: ... main menu to go to UPS Status the line is then highlighted and then press ENTER automatic display after 5 min The UPS status display is divided into several di erent sections to retrieve the following information Display that summarizes all load segment relevant input and output parameters including the information on operation status the current load and the currently available battery capacity ...

Page 88: ...ode No output voltage Bypass deactivate UPS is operating in economical mode ECO mode The display indicates the current UPS status in the top middle section Here is a list of the symbols used and what they mean UPS is in normal continuous double conver sion mode Power supply is available and within the acceptable tolerance range Mode High performance ...

Page 89: ... a successful battery test UPS reports a defective or disconnected battery system UPS is overloaded UPS indicates a critical error and has switched o the UPS output General UPS alarm Details can be found in the Alarm messages and entries in the event log EN ...

Page 90: ...ilable because e g currently not connected Press to access part 2 of the UPS status display It contains current messages and alarms if any Each message or each alarm is displayed in its own window and you can press to scroll through them If there is no information available the following message will appear No active alarms Events are listed and stored in the Event log only a separate menu item wi...

Page 91: ... corner of the display you will find the total number of events already stored as well as your position when scrolling through the window 1 indicates the most recent last stored event starting position when accessed If there are no events stored or if the event memory has been deleted also see Chapter 3 on pg the following message will appear No events in log Accessing the event log Access the eve...

Page 92: ...ant to see any particular measurement on the screen permanently you can free e the screen in the Measurements menu To do so press and for approx 3 seconds at the same time until a small key appears in the upper right hand corner of the display Press the two buttons again at the same time for approx 3 seconds to cancel this setting control 3 4 CONTROL During normal mode you can active this menu ite...

Page 93: ...est Reset Error State Reset Alarms yes no Manually clears any latched alarms such as bad battery detected or DC Bus over voltage under voltage With an active battery fault alarm the battery test status will also simultaneously reset to Not Tested Battery Test Schedule Battery Test 3 5 IDENTIFICATION Activate this menu item to view the following sub menu items Type Model Part number Serial number a...

Page 94: ... disabled Audible alarms enabled disabled NOTE If you dis able audible alarms it takes e ect instantly and remains disabled even after a power cycle This di ers from the mute feature where the horn is temporarily silenced on any button press but turns on again if a new alarm is triggered enabled Set date and time Set Month Day Year Hours and Minutes Date layout mm dd yyyy Time layout hh mm NOTE Th...

Page 95: ...Setting only available in UPS stand by mode auto sensing Output frequency 50Hz 60Hz auto sensing Setting only available in UPS stand by mode auto sensing Load alarm level Overload 10 20 30 100 NOTE The level can be set in 10 increments so a possible overload is detected early 100 Power strategy High performance mode normal Economical mode ECO Converter mode Setting only available in UPS stand by m...

Page 96: ... notice and the Battery Low alarm do not activate during a battery test For automatic battery tests to run The Automatic Battery Test setting must be enabled The UPS must be in Normal mode with no active alarms The battery system being tested must have su icient reserve capacity Automatic battery tests run according to periodic battery test unless disabled During the test the UPS transfers to Batt...

Page 97: ... no yes If no no action If yes the Cumulative Consumption kWh value is cleared and the date and time stamp for this statistic is set to the current date and time no Battery limit time 5h 6h 14h 15h 16h 999h disabled Default 14h means when work on battery mode for more than 14 hours UPS will make bat low alarm and then shutdown itself 30 minutes later even battery voltage still above the shutdown v...

Page 98: ...y events are currently stored in the log Press the ENTER button for one second to reset the event count to zero and clear the log LCD Contrast 5 4 1 0 1 4 5 0 Restore Factory Settings no yes Setting only available in UPS stand by mode Restoring the factory settings returns all user configurable EEPROM settings to default factory settings resets all pending on o commands Clears the Event Log and re...

Page 99: ... There is a cover on the rear panel of the UPS see no 7 on page 8 remove it to install additional optionally available communication components e g Relay card Plug in card with status messages reali ed via potential free relay contacts opener or closer Relay PRO card As above but with programmable pin allocation connection via terminal additional option of remote On O SNMP card Plug in card for th...

Page 100: ... TIVUEPXO TDIFEVMJOH DBO QSPQPTF UXP EJGGFSFOU TPMVUJPOT EWBODFE TPGUXBSF QBDLBHF PNQV8BUDI JUF TPGUXBSF QBDLBHF 8JO1PXFS 8JO1PXFS PNQV8BUDI PS NPSF EFUBJMT QMFBTF WJTJU XXX BFHQT DPN VOEFS 1SPEVDUT POJUPSJOH 4PMVUJPOT 5IFSF ZPV DBO EPXOMPBE TPGUXBSF QBDLBHF BOE EPDVNFOUBUJPO ...

Page 101: ...that the UPS is switched o and switch it o if necessary remove the plug from the EPO insert on the rear panel of the UPS by unscrewing the 2 outer screws also see pg nVNCFS Connect a potential free opener contact able to manage a load of at least 0 Vdc 30 Vac 20 mA with the pins of the plug To do so use a exible wire with a diameter of min 0 5 mm2 or max 2 5 mm2 replace the plug and lock the inser...

Page 102: ...rOTECT C issues detailed error messages to help you or the maintenance sta to localize and interpret any malfunctions that may occur quickly and with high precision In the following please find process solution suggestions to eliminate the problem that has occurred If you cannot solve the current problem terminate the entire process switch the UPS o and disconnect it from the power supply In this ...

Page 103: ...ble is disconnected Low Battery Warning Alarm 56 Intermittent Alarm The battery time remain ing or battery capacity is lower than the battery low warning level that is defined for this UPS This warning is approximate The actual time to shutdown might vary depending on the UPS load and presence of an extended battery module Shutdown Imminent Alarm 55 Intermittent Alarm The communication to external...

Page 104: ...ower voltage is below the minimum operating range The uninterruptible power supply transfers to Battery mode if supporting load Input Under Over Frequency Alarm 8 Intermittent Alarm The utility power frequency is out of usable frequency range The UPS transfers to Battery mode if supporting load Site Wiring Fault Alarm 194 Intermittent Alarm An alarm triggers when the di erence between the ground a...

Page 105: ...en detected The UPS turns o the charger until the next power recycle Contact your service representative Output Short Circuit Alarm 58 Intermittent Alarm The uninterruptible power supply has detected abnormal low impedance that placed on its output and considers it a short circuit The uninterruptible power supply operates as a constant current source 3 x IN and shuts down after five cycles 100ms H...

Page 106: ...y has detected that one or more fans are not functioning correctly This is an alarm only Contact your service representative immediately and remove the load Fatal EEPROM Fault Alarm 53 Continuous Alarm There is EEPROM data corruption due to a failed device or incorrect ash upgrade Contact your service representative ...

Page 107: ...nced and resistant components To guarantee a continuous and high availability it is recommended to check the unit especially the batteries and the fans in regular intervals at least every 6 months Caution Follow safety and security regulations unconditionally 1 BATTERY CHARGING The battery is automatically charged when the mains is present irrespective of the operating mode This is signaled by the...

Page 108: ...tact our hotline if the time drops drastically compared to the previous measurement 2 3 FAN CHECKING Regularly check the fans for dust build up and noticeably untypical noise develop ment Clean the intake openings if they are blocked Contact our hotline if a fan is running unusually loud or irregularly 3 BATTERY REPLACEMENT Caution A battery can present a risk of electrical shock and can be very d...

Page 109: ... 0 4 lead By ensuring these batteries are disposed of correctly you will help prevent potentially negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of the battery The recycling of the materials will help to conserve natural resources In case of products that for safety performance or data integrity reasons require a permanent...

Page 110: ... specified in chapter 1 battery charging 1 2 DISMANTLING The system is dismantled in reverse order of the installation instructions 1 3 DISPOSAL 5IJT TFDUJPO UFMMT ZPV IPX UP EJTQPTF PG UIF JOEJWJEVBM DPNQPOFOUT PG UIF FRVJQNFOU s 1BDLBHJOH JTQPTF PG UIF TUSFUDI QMBTUJD GJMN BOE UIF NPVMEFE QBSUT NBEF GSPN QPMZFUIZMFOF GPBN XJUI OPSNBM JOEVTUSJBM XBTUF 5IFZ BSF DIFNJDBMMZ JOBDUJWF BOE DBO CF EJTQP...

Page 111: ... PG JO DPNQMJBODF XJUI MPDBM MFHJTMBUJPO BOE SFHVMBUJPOT FWFS EJTQPTF PG VTFE CBUUFSJFT PS CBUUFSZ NBUFSJBM XJUI SFGVTF OTVSF DPNQMJBODF XJUI MPDBM MFHJTMBUJPO BOE SFHVMBUJPOT HPWFSOJOH UIF TUPSBHF IBOEMJOH BOE EJTQPTBM PG CBUUFSJFT BOE CBUUFSZ NBUFSJBM EN ...

Page 112: ...stors with minimum control power requirement MOSFET structure and minimum losses on the output side structure of a bipolar transistor Class D See device protection LED Light Emitting Diode Electronic semiconductor component commonly called light diode Used for optical signalling PFC Power Factor Correction Circuitry to minimize system perturbation especially important when connecting non linear lo...

Page 113: ...ependent from mains supply The UPS output is independent of mains voltage and frequency variations The mains voltage however is rectified by electronic passive voltage regulators Former notation LINE INTERACTIVE VFI Output Voltage and Frequency Independent from mains supply The UPS output is independent of mains voltage and frequency variations Former notation ONLINE EN ...

Page 114: ...mode C Cold Start Communication Connections Control Panel D Device Overload Dimensions Display Display Elements E Emergency G Guidelines H Hotline I Indicators M Malfunctions N Normal mode O Overload P Power supply S Settings System Description T Technical Information U USB 93 74 ...

Page 115: ...NOTES EN ...

Page 116: ...NOTES ...

Page 117: ...NOTES EN ...

Page 118: ...NOTES ...

Page 119: ...f concrete enquiries and customer notification of the relevant conditions Due to the non binding nature of these terms we assume liability neither for the accuracy nor completeness of the data provided here Product manufactured in China AEG is a registered trademark used under license from AB Electrolux AEG Power Solutions Emil Siepmann Str 32 I 59581 Warstein Belecke I Germany I Tel 49 180 523 47...

Reviews: