47
c)
Fix chimney stack A to the hood unit C using four of the screws
provided E (fig.21).
d) Insert the transparent seal Q (provided), so as to eliminate any
play between the two parts of the chimney (fig. 22). Lock the
screws M.
e) Remove the support rod B.
Ducting or recirculation fitting
1 - Ducting fitting.
This is possible for all forms of installation:
a) Connect the air outlet to the external ducting
system.
b) Remove the activated charcoal filter (if there is
one) inside the hood canopy (see Maintenance).
2 - Recirculation fitting
This is only possible with the air outlet directed
upwards. Fit the venting grille G onto the air outlet (Fig. 23).
The activated charcoal filter should be fitted inside the hood
canopy after connection to the power supply.
Connection to power supply and checking of
good working order
1 - It is absolutely necessary to follow the warnings 3.2, 3.3 and 3.4 of
paragraph 3, concerning safety measures.
2 - Loosen the two locking screws and remove the metal cover (fig.24).
Connect the hood connection to the engine connection (fig.25a)
.
Correctly place the connectors under the cover and tighten the two
locking screws (fig. 25b).
3 - Once electrical connection has been carried out, check that lights,
engine and change of speed work
4 - Fit the antigrease filter (see Maintenance).
D
A08_22
20
E
E
E
E
A08_23
21
Q
A08_24
Q
22
G
23
S07_24
24
S07_34
25a
25b
Installation
Summary of Contents for Electrolux DD8692-M
Page 83: ...83 ...
Page 84: ...436002473_01 050119 ...