Instructions for the Installer
The following instructions are meant for a qualified installer, in order
that the operations of installation, regulation, and service are carried
out according to the regulations in force.
Installation Environment
Warning - This unit can be installed and can operate in constantly
ventilated rooms only, according to rules in force.
In order to make the gas unit operate properly, a continuous air supply
must be ensured for a correct gas combustion. (The installer must
follow the rules in force).
The air supply must be obtained through direct opening on external
walls. These opening (or openings) should be maintained in good
condition and not be obstructed both from the outside and the inside.
Installation, gas and electric connection and maintenance must be
carried out by a qualified technician, in compliance with rules in force.
Positioning
This appliance has been registered as Class "X" appliance. It can placed
close to furniture units not exceeding the height of the working top
(EN 60 335-2-6).
Levelling
The appliance is provided with
adjustable small feet placed on the
base corners.
Adjust the small feet to change the
height of the appliance, in order to
ensure an even levelling with the
other furniture units and a safe
operation when cooking on the
hob burners.
The manufacturer disclaims any responsibility should all the safety
measures and installation instructions not be carried out.
Combustion Products Discharge
Gas cooking units must discharge combustion products through hoods
directly connected to flues or outside.