WARNING!

 Always switch off and unplug the 

machine from the mains power source before 

assembling, opening, emptying the dirt tank, 

before connecting/disconnecting the attachments, 

or carrying out maintenance or troubleshooting 

checks.

IMPORTANT!

 If the hose or tools are blocked, switch off the 

cleaner and remove the blockage(s) before re-starting your 

machine.

PLEASE KEEP THESE INSTRUCTIONS FOR FURTHER 

USE.

• 

Never vacuum up hot ashes, pointed or sharp objects.

• 

Never use the appliance in damp rooms.

• 

Don’t use the appliance without a dust bag (an exception is 

wet vacuuming or with the cartridge filter). Make sure that 

the dust bag is inserted into the appliance correctly.

• 

When using the appliance, make sure that no hair, clothing, 

or members are drawn in.

• 

Keep the vacuum cleaner away from heat sources such as 

radiant heaters, ovens, and so on.

DAMAGE TO THE VACUUM CLEANER CAUSED AS A 

DIRECT RESULT OF NOT ADHERING TO THE GENERAL 

SAFETY INFORMATION AND THE INSTRUCTIONS IN 

THIS USER GUIDE INVALIDATES THE WARRANTY.

IMPORTANT!

 Cleaning filters and replacing them regularly 

maintains vacuum performance. AEG recommends that your 

filters should be checked, cleaned and replaced periodically.

40. Electrical power should be supplied via a residual current 

device (RCD) with a tripping current of not more than 

30mA.

41. Only use a weather proof extension cord. Check the 

extension cord before every use for damage. Always 

uncoil the extension cord during use because coiled cords 

can overheat. Damaged extension cords should not be 

repaired, they should be replaced with an equivalent type.

GENERAL SAFETY PRECAUTIONS 

FOR USING WORKSHOP VACUUM

ADDITIONAL SAFETY INSTRUCTIONS

FOR  WORKSHOP VACUUM

4

Summary of Contents for AVC-1530-G

Page 1: ...AVC 1530 G WET DRY VACUUM CLEANER Instructions for use ...

Page 2: ... vacuum Pay close attention to the Rules for Safe Operation Warnings and Cautions If you use your workshop vacuum properly and only for what it is intended you will enjoy years of safe reliable service Thank you again for buying AEG tools SAVE THIS MANUAL FOR FUTURE REFERENCE Specification and Technical Data Model Supply voltage Motor power Max power take off Tank volume Hose system Filter dry Fil...

Page 3: ...utlet 34 Exhaust filter cover 1 Hose set 2 Power tool adaptor 3 Crevice tool 4 Floor tool 5 Round brush 6 Steel wand x2 7 Accessory adaptor 8 HEPA cartridge filter x1 9 HEPA filter cap x1 10 Dust bag 11 Foam filter 12 Steel elbow 21 13 Rear wheel x2 14 Hub cap x2 15 R lock pin x2 16 Washer x4 17 Wheel axle 18 Front caster x2 19 Upper push handle 20 Lower handle support x2 21 Power cable hook x2 22...

Page 4: ...ntact tool or extension cord 7 Use right tool Don t force small tool or attachment to do the job of a heavy duty tool Don t use tool for purpose not intended 8 Dress properly Do not wear loose clothing or jewellery They can be caught in moving parts Rubber gloves and nonskid footwear are recommended when working outdoors Also wear protective hair covering to contain long hair 9 Always wear safety ...

Page 5: ...any legal regulations 34 Only store the appliance in a safe and dry location outside the reach of children 35 Please also pay particular attention to the following Additional Safety Instructions For Workshop Vacuum 36 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been gi...

Page 6: ...e drawn in Keep the vacuum cleaner away from heat sources such as radiant heaters ovens and so on DAMAGE TO THE VACUUM CLEANER CAUSED AS A DIRECT RESULT OF NOT ADHERING TO THE GENERAL SAFETY INFORMATION AND THE INSTRUCTIONS IN THIS USER GUIDE INVALIDATES THE WARRANTY IMPORTANT Cleaning filters and replacing them regularly maintains vacuum performance AEG recommends that your filters should be chec...

Page 7: ... contents from inside the tank make sure you have all contents as listed in component list Fig 3 5 Turn the tank upside down and insert the two caster feet into the front slots on the base Apply downward pressure to each caster Casters will snap into place when installed properly Verify that the casters are mounted correctly Fig 4 6 Insert the wheel axle into the base Insert washer onto the axle f...

Page 8: ...d dust collecting fit collection bag flange onto the inlet stub taking care not to damage the bag Fig 18 5 Place the power head back on the tank and secure it in place using the latches Fig 19 1 Verify that the power cord is disconnected from the mains power source 6 Insert the locking end of the hose into the vacuum port and lock in place Push the required attachment onto the free end of the hose...

Page 9: ...position Fig 25 4 After use empty the tank by unscrewing the drain cap Drain liquids into a suitable receptacle or drain Remember to refit the drain cap to the tank after draining tank Fig 26 CONNECT THE MAINS PLUG WET VACUUMING DO NOT USE THE HEPA FILTER FOR WET VACUUMING OPERATING INSTRUCTIONS WET VACUUMING Leave a gap at the tip of the nozzle opening to allow air inflow The machine is fitted wi...

Page 10: ...all dust particles The HEPA cartridge filter should be used for dry pick up only Do not wash the HEPA filter A dry HEPA cartridge filter is necessary to pick up dust If the HEPA cartridge filter is wet it will clog quickly and be very difficult to clean Handle the HEPA cartridge filter carefully when removing it for replacing it Check the HEPA cartridge filter for tears or small holes a small hole...

Page 11: ...down position carefully remove foam sleeve filter Fig 36 2 Use a mild soap and water solution to wash foam sleeve filter and rinse with clean water Fig 37 3 Allow filter to air dry before installing and using again Cleaning Foam Sleeve Filter Fig 35 Fig 36 Fig 38 Fig 39 Fig 40 Fig 41 Fig 42 Fig 44 Fig 43 Fig 37 9 INSTALLING CLEANING FOAM SLEEVE FILTER INSTALLING CLEANING EXHAUST FILTER When the co...

Page 12: ...from motor cover Reduced efficiency and motor speed vibration 1 No power supply 2 Faulty power cord 3 Tank full 1 The cartridge filter is missing or damaged 2 HEPA cartridge filter is not installed correctly 1 There is a blockage in the nozzle hose or the tank inlet The cartridge filter is clogged by fine dust 2 Dust bag is full 2 Replace the dust bag 1 Check power supply cord breakers fuses 2 Unp...

Page 13: ...11 NOTES ...

Page 14: ...12 NOTES ...

Page 15: ...13 NOTES ...

Page 16: ...s GmbH Max Eyth Straße 10 71364 Winnenden Germany Techtronic Industries Australia Pty Ltd 31 Gilby Road Mount Waverley VIC 3149 Australia Techtronic Industries N Z Limited 2 Landing Drive Mangere Auckland New Zealand 2022 ...

Reviews: