1. Verify that the power cord is disconnected from the mains
power source.
2. Disconnect the hose from the vacuum. (Fig. 27)
3. Undo the latches and remove the power head from the tank.
(Fig. 28)
4. Clear all dirt or debris from the tank and hose. (Fig. 29)
5. Clean the foam filter by washing it with water and mild soap.
(Fig. 30)
6. Check the hose, attachments, and power cord to verify that
they have not been damaged.
WARNING!
ALWAYS DISCONNECT THE PLUG
FROM THE MAINS POWER SOURCE BEFORE
REMOVING THE POWER HEAD FROM THE TANK.
1. Verify that the power cord is disconnected from the mains
power source.
2. Remove power head and place in upside down position.
Installing HEPA Filter And Pre-filter
1. Remove pre-filter from the tank.
2. Unlock and remove the filter cap by tuning cap counter
clockwise.
3. Carefully hold and pull the HEPA filter up for removal.
(Fig. 34)
4. Wet filter should be removed and allowed to air dry for 24
hours before installing onto the filter cage.
Removing HEPA Filter And Pre-filter
8
MAINTENANCE
INSTALLING HEPA FILTER AND
PRE-FILTER
Fig. 27
Fig. 28
Fig. 31
Fig. 33
Fig. 34
Fig. 32
Fig. 29
Fig. 30
NOTICE!
The HEPA cartridge filter included is made of high
quality materials designed to stop small dust particles. The
HEPA cartridge filter should be used for dry pick-up only.
Do not wash the HEPA filter.
A dry HEPA cartridge filter is necessary to pick up dust. If the
HEPA cartridge filter is wet, it will clog quickly and be very
difficult to clean. Handle the HEPA cartridge filter carefully
when removing it for replacing it. Check the HEPA cartridge
filter for tears or small holes, a small hole can let dust pass
through and out of the cleaner.
Do not use a HEPA cartridge filter with holes or tears, replace
it immediately.
Clean the cartridge filter by gently tapping or brushing dirt off.
For optimal performance it is recommended to regularly
change this filter depending on level of use (eg. 3-6 months).
IMPORTANT!
Change the cartridge filter regularly for best
performance. ALWAYS USE THE HEPA FILTER FOR DRY
VACUUMING. If the machine is used for dry vacuuming
without the HEPA filter and cap attached, the motor will burn
out and the warranty will be voided.
3. Install the HEPA filter over the filter cage with the flat end of
the filter towards the vacuum power head. Carefully push
filter in until it stops against the power head. (Fig. 31 )
4. Place filter cap on top of cartridge filter over the raise lip and
tighten down by turning cap Clockwise, do not over tighten.
(Fig. 32)
5. Place the pre-filter into the tank and press the hoop
downward until it stops against the tank edge. (Fig. 33)