ARE I2 / RS 232 – Installation Guide
AEG
Identifikationssysteme GmbH
Söflinger Straße 100
D-89077 Ulm
Tel. ++49(0)731-933-1340/1877
Fax ++49(0)731-933-1855
e-mail: [email protected]
0
one out of one (no effect)
1
two out of two ; (default value)
Output (example): 1 <CR>
Sequence of readings
Length of the reading cycle
Result of the reading cycle
NoRead
1 reading
NoRead
0000125ED1, 000012
5
ED1
2 readings
0000125ED1
0000125ED1, 000012
6
ED1
2 readings
NoRead
Schedule 6-: example for a reading cycle with NID=1
Example: A, B, C are specific different transponder numbers, N is NoRead:
Sequence of reading cycles
Output sequence after
filtering with CN=0 and
CID=1
Output sequence after
filtering with CN=1 and
CID=1
N, N, ......,N, A, A, A, ....A, N,N, .........
N, N, ......,N, A, N, N,
.......
A
N. N, N, A, A, A, N, A, A, B, A, C, C, C, ....... N. N, N, A, N, B, A, C,
.....
A, B, A, C
N, N, B, B, B, B, B, N, N, N, B, B, B, B, N,
N,...
N, N, B, N, N, N, N, N,... B
N, N, N, B, B, B, B, B, N, B, B, B, B, N, N, N,
....
N, N, N, B, N, N, N, N,
....
B
Table 6-: example for the effect of the CID function
Annotation:
The internal reference number is deleted in the following conditions:
•
after a cold start
•
after a warm start
•
after entering the command line CID <SP> 1 <CR>
This causes that the next transponder code is output definitely.
Caution:
The filter function CID picks up the results of the complete
reading
cycles
, while the parameter NID proceeds from the results of single
readings
! The filter function CID has effect on the serial interface
only.