42
Installation - for contractors
Cleaning the strainer
You can clean the fitted strainer after removing the cold
water supply pipe.
26
_0
2_0
5_00
65
_
Checking the earth conductor
» Check the earth conductor (in Germany e.g. BGV
A3) on the earth conductor contact of the power
cable and on the appliance connector.
Appliance storage
» Store the dismantled appliance in a room free from
the risk of frost, as water residues remaining inside
the appliance can freeze and cause damage.
Replacing the power cable for the
MTE 570
» If replacing the cable for the MTE 570, use a power
cable with 4 mm² cross-section.
15.
Specification
15.1
Dimensions and connections
95
28
30
120
143
190
4,8
165
82
20
b02
b03
c06
c01
D
00000
18
33
6
b02 Entry electrical cables I
b03 Entry electrical cables II
c01 Cold water inlet
Male thread
G 3/8 A
c06 DHW outlet
Male thread
G 3/8 A