3.4.4

 

RD – read page 

 

Start the reader with the command RD plus parameters (plus <CR>). You can read out just one 

block (with one parameter) or several blocks (with two parameters, first and last block number). 

 

Wait for the answer 

 

Analyse the received answer: 8 characters plus <CR>. Allowed characters  0 to F. 

The NoRead code is set to ( „XXXXXXXX“). 

The result of the reading process may also be seen at the LED’s. 

 

LED L2 lit, if there was a successful read. 

 

LED L3 lit, if there was a No Read. 

 

Example: 

RD

 <SP> 

20 

<CR> 

 

read block 20 

RD 

<SP> 

16 

<SP>

 33 

<CR>

 

read all blocks from 16 to 33 

Allowed values (block numbers of the transponder IC): 

ALGO 9 (1 kBit; P4150, P4450, P4550)

 

 

3 ... 33

 

ALGO 6 (2 kBit; Hitag 1)

 

 

 

 

16 ... 63

 

ALGO 14 (2, 4; kBitEM4305, EM4569) 

 

5 … 15 

 

Summary of Contents for ARE DT1 LF

Page 1: ...ARE DT1 LF Installation Guide...

Page 2: ...ST reset 10 3 2 5 VER version 10 3 2 6 HF Antenna field 11 3 2 7 HID human interface device keyboard 11 3 2 8 KL keyboard language 13 3 3 Instructions for reading settings 14 3 3 1 CID suppression of...

Page 3: ...3 28 4 OPERATING MODES OF THE READER 24 4 1 MD 2 triggered by an software command 24 4 2 MD 0 continuous reading 25 5 INSTRUCTIONS 26 6 FCC INFORMATION 27 7 HOTLINE 28 8 REVISIONS 28...

Page 4: ...ID reading device ARE DT1 LF and the set up procedure The main features of the reader are listed below integrated USB interface selectable either communications port similar RS232 or HID USB powered n...

Page 5: ...der The reader answers with the actual firmware version e g AEy ID Multi ISO V2 034 Send the command MD SP 0 CR to the reader The reader sends No Read messages XXXXXXXX while there is no transponder i...

Page 6: ...y the reader The following response protocols are different 3 1 2 1 Instruction specific output After entering a valid command without a parameter value the system answers by sending the param eter va...

Page 7: ...ank instuction If a single CR is input the reader answers with a single CR Example Command CR Output CR 3 1 4 Incorrect instruction error codes If a command is not entered correctly the reader sends o...

Page 8: ...r and lower case The instruction set isn t case sensitiv 3 1 6 Linefeed The reader does never send a linefeed If you use a terminal program it can add the linefeed You have to choose the option displa...

Page 9: ...tings are directly effective Input format BD SP parameter CR Output example 2 CR Parameter PARAMETER FUNCTION 0 4800 baud 1 9600 baud 2 19200 baud 3 38400 baud 3 2 2 EC Echo The EC command allows to c...

Page 10: ...Buzzer beeps LEDs flash final state initial state 3 2 4 RST reset With the command RST the reader does a warmstart and loads the saved settings from the internal EEPROM The antenna field is off after...

Page 11: ...comunicate with the transponder afterwards it is switched off automatically Therefore it is not compatible with the pass word mode The reader answers with the adopted antenna mode Input examplel HF SP...

Page 12: ...e Set Up card interface to switch the reader back from HID mode to serial interface mode 1 Plug out the reader 2 Place card no reader 3 Plug in reader into USB port 4 Wait for the beep tone from reade...

Page 13: ...command KL you can configure the language of the keyboard in HID mode Input format KL SP parameter CR Output example 07 CR Parameter PARAMETER FUNCTION 07 german 09 englisch 0A spanish 0C french 10 i...

Page 14: ...fluenced by this command NoReads do not influence the data filtering The leds are not influenced by this command Input format CID SP parameter CR Output example 0 CR Parameter PARAMETER FUNCTION 0 No...

Page 15: ...he complete reading cycles while the parameter NID proceeds from the results of single readings The filter function CID has effect on the serial in terface only 3 3 2 CN suppression of No Reads Throug...

Page 16: ...etting NID 1 two successive readings have to show the same transponder number Input format NID SP parameter CR Parameter PARAMETER FUNCTION 0 One out of one 1 Two out of two Output example 1 CR Sequen...

Page 17: ...ommand LAA If the reading settings CN 1 CID 1 CE 1 when SI 0 MD 0 and LAA 0 are set the reader beeps and flashes after successful reading This setting makes sense when reader is used with HID setting...

Page 18: ...eps 0 2 to 12 6s 3 3 7 TOR maximum reading time TOR is the timeout time for the reader TOR is used in operation mode 2 as maximum gating time for a reading process The length of the maximum gating tim...

Page 19: ...CID CN KM1 KT1 LAA MD SI TL1 TOR Input format VSAVE CR Output example ACK CR 1 just available in the ISO 14443A standard 2 just available in the ISO 15693 standard 3 3 9 VS variables show With the com...

Page 20: ...algorithms This algorithm specific commands are listed in the Addon_A documents Which reading algorithms are available dends on the type of reader not every reader type supports all types of transpond...

Page 21: ...utput example 2 CR Parameter PARAMETER FUNCTION 0 constant reading mode 2 single reading mode 3 4 3 Basic data exchange process The master has to send an software command to start an read or write pro...

Page 22: ...characters plus CR Allowed characters 0 to F The NoRead code is set to XXXXXXXX The result of the reading process may also be seen at the LED s LED L2 lit if there was a successful read LED L3 lit if...

Page 23: ...the received answer 3 characters plus CR ACK CR Writing process was successful NAK CR Writing process was not successful NOT CR The response of the transponder was not readable The result of the writ...

Page 24: ...mode 2 the exciter is always turned off Triggered by the software command yT RD WD the exciter is activated After successful reading or writing of a transponder number the exciter is turned off automa...

Page 25: ...continuously the exciter is switched on permanently The reading cycles are initiated periodically After an accomplished reading cycle the reading information is evaluated After that data either tran s...

Page 26: ...ic It depends also strongly on the orienta tion between Reader and Transponder To get the maximum reading distance the orientation between reader and transponder must be well suited Optimum orientatio...

Page 27: ...found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residenti...

Page 28: ...1 30 13 Revision 01 chapter 3 3 9 TSC time show code added chapter 3 6 9 SF set flag added 01 21 13 Revision 02 adapt to LF 11 20 13 Revision 03 ALyO command 09 18 14 Revision 04 USB power supply MK 0...

Reviews: