3.3.6
TSC – time show code
With the command TSC you can define the time in ms, after that the transpondercode is shown again,
when the CID parameter is set to 1. If TSC is 00, the code is not shown a second time.
Input format:
TSC
<SP>
parameter
<CR>
Output (example):
00
<CR>
PARAMETER
FUNCTION
00
TSC is not active
01..63
TSC time in 200 ms
steps (0.2 to 12.6s)
3.3.7
TOR – maximum reading time
TOR is the timeout time for the reader. TOR is used in operation mode 2 as maximum gating time for
a reading process. The length of the maximum gating time results from the equation gating_time =
TOR * TB.
The time constant TB (time base) has always the default value 100ms.
Input format:
TOR
<SP>
parameter
<CR>
Output (example):
05
<CR>
Parameter:
PARAMETER
FUNCTION
00h
limits the reading process duration of exactly one reading cycle
01h..FFh
limits the reading process duration to maximum 1..256 times
TB