![AEG ID ARE DT1 LF Installation Manual Download Page 20](http://html1.mh-extra.com/html/aeg-id/are-dt1-lf/are-dt1-lf_installation-manual_2860290020.webp)
--------------------------------------------------------------------------------20/28--------------------------------------------------------------------------------
3.3.10
ALGO – algorithm selection
With the command ALyO the algorithm can be selected. Depending on the algorithm, the reader adapts
its communication to the transponder suitable for the chip type respectively data format that shall be
used. In some algorithms specific commands are provided additionally. For example the selective read
and write commands (RD, WD) are only supported with read write transponders and its algorithms. This
algorithm specific commands are listed in the “Addon_A..” documents.
Which reading algorithms are available dends on the type of reader, not every reader type supports all
types of transponders.
Input format:
ALGO
<SP>
parameter
<CR>
Output (example):
4
<CR>
Parameter:
PARAMETER
FUNCTION (CHIP, FORMAT)
4
ASK 64 Bit
5
ISO FDX
6
HiTag1 und HiTagS
14
EM 4569 und 4305
3.3.11
VH – filter tracing
The parapeter VH is activating an automatical input filter tracing. It is switched on by default and
should not be deaktivated without reason.
Input format:
VH
<SP>
parameter
<CR>
Output (example):
1
<CR>
Parameter:
PARAMETER
FUNCTION
0
Off
1
On