Installation 2-4
Cooling Continued
At the bottom of the rack, mount the blower so it blows outside air into the space
between the door and front of the amplifiers, pressurizing the chimney" behind
the door. This blower should not blow air into or take air out of the space behind
the amplifiers. For racks without a door, you can evacuate the rack by mounting
the blower at the top of the rack so that air inside the cabinet is drawn out the back
(Option 2 previous page).
If the air supply is unusually dusty, you might want to pre-filter it using
commercial furnace filters to prevent rapid loading of the unit's own air filters.
When needed, the unit's filters can be cleaned with mild dish detergent and water.
You may want to allow at least two additional inches of depth for cables and
connectors extending out from the back.
DO NOT Install the
LVC 608/623/2016
in a
small sealed chamber of any kind. Improper
operation and overheating will result.