6. Specifications
Model
TOPV1000
TOPV1500
TOPV2000
TOPV3000
CAPACITY*
1000 VA / 800 W 1500 VA / 1200 W 2000 VA / 1600 W 3000 VA / 2400 W
INPUT
Low Line Transfer
160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5 %
( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)
Low Line Comeback
175 VAC ± 5 %
High Line Transfer
300 VAC ± 5 %
Voltage
Range
High Line Comeback
290 VAC ± 5 %
Frequency Range
40Hz ~ 70 Hz
Phase
Single phase with ground
Power Factor
0.95
OUTPUT
Output voltage
208/220/230/240VAC
AC Voltage Regulation
(Batt. Mode)
± 3%
Frequency Range
(Synchronized Range)
47.5 ~ 52.5 Hz or 57 ~ 63 Hz
Frequency Range (Batt. Mode)
50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
Overload
100%~110%: warning
110%-130%: sounding every 12 seconds
>130% : sounding every 1.5 seconds
Current Crest Ratio
3:1
Harmonic Distortion
3 % THD (Linear Load)
6 % THD (Non-linear Load)
4 % THD (Linear Load)
7 % THD (Non-linear Load)
AC Mode to Batt. Mode
Zero
Transfer
Time
Inverter to Bypass
4 ms (Typical)
Waveform (Batt. Mode)
Pure Sinewave
EFFICIENCY
AC Mode
~ 85%
~ 88%
Battery Mode
~ 83%
BATTERY
Battery Type
12 V / 7 AH
12 V / 9 AH
12 V / 7 AH
12 V / 9 AH
Numbers
3
3
6
6
Recharge Time
4 hours recover to 90% capacity (Typical)
Charging Current
1.0 A(max.)
Standard
Model
Charging Voltage
41.0 VDC ± 1%
82.1 VDC ±1%
Battery Type &
Numbers
Depending on the capacity of external batteries
Charging Current
4.0 A or 8.0 A(max.)
Long-run
Model
Charging Voltage
41.0 VDC ± 1%
82.1 VDC ±1%
PHYSICAL
Dimension, D X W X H
397 X 145 X 220 (mm)
421 X 190 X 318 (mm)
Tower
Case
Net Weight (kgs)
13
7
14
7
26
13
28
13
Dimension, D X W X H
420x438x88[2U] (mm)
580x438x133[3U] (mm)
Rack
Case
Net Weight (kgs)
16
10
17
10
29
17
31
17
ENVIRONMENT
Operation Humidity
20-90 % RH @ 0- 40°C (non-condensing)
Noise Level
Less than 45dBA @ 1 Meter
MANAGEMENT
Smart RS-232 or USB
Supports Windows 98 SE/ME/NT 4.x/2000/2003/XP/Vista/2008
Optional SNMP
Power management from SNMP manager and web browser
•
Derate capacity to 60% of capacity in Frequency converter mode and to 80% when the output voltage is
adjusted to 208VAC.
Summary of Contents for TOPV 1500
Page 19: ...18 APPLY administrator...
Page 20: ...19 Next Open Monitor...
Page 21: ...20 1 2 Install...
Page 22: ...21 ViewPower ViewPower...
Page 23: ...22 EP 28 43 14 1 2 3 4 11 12 13 41...
Page 24: ...23...
Page 28: ...27 4 10 ENA DIS ESC HLS LLS BAT CF EP EPO FA TP CH 3 1 8 1 2 3 4 5 6 7 8 1 2 3...
Page 29: ...28 H M S Vac Vdc Hz 0 25 26 50 51 75 76 100 4 Bypass 4 0 25 26 50 51 75 76 100 Vac Vdc Hz...
Page 30: ...29 ON Mute Button 2 5 OFF Enter Button 2 Select Button 10 5 5...
Page 31: ...30 Top Vision 24 03 9000 940 03 9000900 03 9027444 10 48091...