The connector settings define the data flow which is the rule for processing the
LoRaWAN data. For example, data comes with the handler rule should be
saved to the MQTT broker or websocket.
The broker and websocket on the WISE-6610 Series is enabled by default. The
uplink from the sensor node comes with the MQTT topic is
uplink/{devaddr}
and the downlink topic is
out/{devaddr}
.
Figure 4.14 LoRaWAN Server > Backends > Connectors
D/L Expires
Click the drop-down menu to define when the downlinks may be
dropped.
Never:
–
All class A downlinks for a device will be queued and eventu-
ally delivered.
–
All confirmed downlinks will be retransmitted until acknowl-
edged even when a new downlink is sent.
When Superseded:
–
Only the most recent class A downlinks will be scheduled for
delivery. Superseded downlinks will be dropped.
–
Unacknowledged downlinks will be dropped when a
new downlink (either class A or C) is sent.
Submit
Click
Submit
to save the values and update the screen.
Item
Description
fun(Fields,Port, <<DEV, Temp:16, Hum:16, Sensor:16>>) ->
if
DEV==1 ->
Fields#(device => co2, temp => Temp/100, hum => Hum/100, sensor => Sensor);
DEV==2 ->
Fields#(device => co, temp => Temp/100, hum => Hum/100, sensor => Sensor);
DEV==3 ->
Fields#(device => pm25, temp => Temp/100, hum => Hum/100, sensor => Sensor);
true ->
false
end
end.
Summary of Contents for WISE-6610 Series
Page 1: ...User Manual WISE 6610 Series Indsutrial LoRaWAN Gateway...
Page 12: ...Chapter 1 1Product Overview...
Page 16: ...Chapter 2 2Gateway Installation...
Page 24: ...Chapter 3 3Managing Gateway...
Page 47: ...36 WISE 6610 Series User Manual Figure 3 25 Configuration 1st Tunnel...
Page 79: ...Chapter 4 4Configuration in Typical Situations...